background image

12

Before discarding packaging material, be certain all

parts have been removed.

HOW TO ORDER REPAIR PARTS

WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE
FOLLOWING INFORMATION:

• PART NUMBER

• PART DESCRIPTION

• NAME OF ITEM

• MODEL NUMBER

For repair parts, phone 1-800-654-3545.

Repair Parts Listing

Model Numbers

Key

No.

Description

CF787AW01 CF787BS01 CF787GBZ01 CF787GES01 CF787ORB01 CF787AP01 CF787VNB01 CF787CK01

*

Hanger Ball Assembly,

761655-21

761655-17

761655-77

761655-35

761655-32

761655-34

761655-89

761655-23

Consisting of:

1

Hanger Bracket

2

Hanger Ball

3

Downrod (4.5”)

*

Parts Bag Containing:

763796-3

763796-3

763796-4

763796-4

763796-4

763796-3

763796-4

763796-3

4

Wire Connector (4)

5

Pin, Clevis

6

Clip, Hairpin

7

Screw, Flat Head M4 x 12mm (1)

8

Screw, Pan Head M6 x 14mm,

with Lockwasher (1)

9

Screw, Washer Head

M5 x 12mm (21)

10

Flat Washer 16mm OD (21)

11

Threaded Stud (2)

12

Lockwasher (2)

13

Knurled Knob (2)

14

Balancing Kit (1)

15

Canopy, Ceiling (1)

763785-AW

763785-BS

763785-GBZ 763785-GES 763785-ORB 763785-AP

763785-VNB

763785-CK

16

Wiring Harness (1)

764026-1

764026

764026

764026

764026

764026

764026

764026-1

17

Switch Housing (1)

764027-AW

764027-BS

764027-GBZ 764027-GES 764027-ORB 764027-AP

764027-VNB

764027-CK

18

Coupling Cover (1)

763786-AW

763786-BS

763786-GBZ 763786-GES 763786-ORB 763786-AP

763786-VNB

763786-CK

19

Flange (set of 5)

763792-AW

763792-BS

763792-GBZ 763792-GES 763792-ORB 763792-AP

763792-VNB

763792-CK

20

Wall Control, 4-Speed Slide

761971-1

761971-1

761971-1

761971-1

761971-1

761971-1

761971-1

761971-1

Owner's Manual

BP7377-5

BP7377-5

BP7377-5

BP7377-5

BP7377-5

BP7377-5

BP7377-5

BP7377-5

U.L. Model No.: CF787

Summary of Contents for CARRERA GRANDE CF787 series

Page 1: ...Ceiling Fan Owner s Manual CF787AW01 Summer White CF787AP01 Antique Pewter CF787BS01 Brushed Steel CF787CK01 Chalk CF787GBZ01 Gilded Bronze CF787GES01 Golden Espresso CF787ORB01 Oil Rubbed Bronze CF787VNB01 Venetian Bronze Model Numbers CARRERA GRANDE 54 60 or 72 Fan Blades Not Included Net Weight 25 3 Lbs ...

Page 2: ... are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for th...

Page 3: ...nterrupted Before assembly your ceiling fan refer to section on proper method of wiring your fan page 8 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 This product is designed to use only those parts supplied with this product and or any acc...

Page 4: ...s are NOT tightened Figure 3 Repeat this procedure for other four blade assemblies How to Put Your Ceiling Fan Together Electrical Requirements If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circui...

Page 5: ...ion in Step 9 9 Separate untwist and unkink the three 80 motor leads Route the motor lead wires through the downrod Remove the upper setscrew from the motor coupling Align the clevis pin holes in the downrod with the holes in the motor coupling Install the clevis pin and secure with the hairpin clip Figure 7 The clevis pin must go through the holes in the motor coupling and the holes in the downro...

Page 6: ...wnrod Be sure that the ceiling cover and the coupling cover are both oriented correctly Figure 8 6 It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed could result in the fan falling WARNING HAIRPIN CLIP CLEVIS PIN UPPER SETSCREW CLEVIS PIN SETSCREW HAIRPIN CLIP MOTOR...

Page 7: ... HANGER BALL DOWNROD ASSEMBLY NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY Figure 12 To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely att...

Page 8: ...ack wire to the supply black hot wire using wire connector supplied Figure 13 3 If a downlight is not being installed cap the blue wire using a supplied wire connector If a downlight is being installed a separate hot supply must be available or an optional Emerson accessory control must be used Follow the installation instruction of the accessory control if used 4 After connections have been made ...

Page 9: ...15 6 If present connect the supply white neutral wire to the branch circuit white neutral wire with a wire connector 1 Remove the wall plate and screws from the existing wall switch Pull switch out from wall outlet box 2 Disconnect wire from existing fan wall switch Figure 15 3 Slide the fan control to the OFF position 0 This control is designed to operate only one ceiling fan TO NEUTRAL TO FAN MO...

Page 10: ...injury 1 Ceiling Fan Light Kits see store or catalog 2 Ceiling Fan Light Controls see store or catalog 3 Downrod Extension Kits see store or catalog 4 Ceiling Fan Blades see store or catalog WARNING WARNING WARNING Using Your Ceiling Fan REVERSE SWITCH IMPORTANT Fan installation must be completed including the installation of the fan blades before testing of the controls 1 Restore electrical power...

Page 11: ... Fans Using the Ceiling Fan Year Round In the summer use the ceiling fan in the counter clockwise direction The airflow produced by the ceiling fan creates a wind chill effect making you feel cooler Select a fan speed that provides a comfortable breeze lower speeds consume less energy In the winter reverse the motor and operate the ceiling fan at low speed in the clockwise direction This produces ...

Page 12: ...crew Flat Head M4 x 12mm 1 8 Screw Pan Head M6 x 14mm with Lockwasher 1 9 Screw Washer Head M5 x 12mm 21 10 Flat Washer 16mm OD 21 11 Threaded Stud 2 12 Lockwasher 2 13 Knurled Knob 2 14 Balancing Kit 1 15 Canopy Ceiling 1 763785 AW 763785 BS 763785 GBZ 763785 GES 763785 ORB 763785 AP 763785 VNB 763785 CK 16 Wiring Harness 1 764026 1 764026 764026 764026 764026 764026 764026 764026 1 17 Switch Hou...

Page 13: ...13 19 6 5 11 1 2 3 BLADES SOLD SEPARATELY 13 12 18 15 14 16 17 4 0 3 2 1 20 10 7 8 4 9 Repair Parts U L Model No CF787 ...

Page 14: ...rs inside switch housing 4 Check to make sure wire connectors in switch rattling housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned OFF 5 Screws holding blades to flanges 5 Tighten screws securely are loose 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Tighten both setscrews securely in the motor excessively...

Page 15: ...center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also...

Page 16: ...U L Model No CF787 Part No F40BP73770005 Printed in China 10 11 Form No BP7377 5 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 ...

Reviews: