background image

7

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.

1.

Connect the green grounding lead from the hanger
ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this
may be a bare wire or wire with green colored
insulation). Securely connect wires using wire
connectors supplied (Figure 12).

2.

Securely connect the fan motor white wire to the
supply white (neutral) wire using wire connector
supplied (Figure 12). Securely connect the fan
motor black wire and blue wire to the supply black
(hot) wire using wire connector supplied (Figure
12). After connections have been made, turn leads
upward and carefully push leads into the outlet
box, with the white and green leads on one side of
the outlet box and the black and blue leads on the
other side of the outlet box.

Wiring The Ceiling Fan

To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is
grounded, contact a licensed electrician for advice,
as it must be grounded for safe operation.

WARNING

!

U.L. Model No.: CF701

Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.

WARNING

!

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked “Acceptable
for Fan Support”, and use screws supplied with
outlet box. Most outlet boxes commonly used for
support of light fixtures are not acceptable for fan
support and may need to be replaced. Consult a
qualified electrician if in doubt.

WARNING

!

The outlet box and joist must be securely mounted
and capable of supporting at least 50 lbs. Use only a
U.L. outlet box listed as “Acceptable for Fan
Support”.

WARNING

!

OUTLET
BOX

HANGER
BRACKET

HANGER BALL/
DOWNROD  ASSEMBLY

NOTE: CEILING COVER,
SUPPLY WIRES AND
FAN WIRES OMITTED
FOR CLARITY.

Figure 11

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.

WARNING

!

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.

WARNING

!

TWO SCREWS
SUPPLIED WITH
OUTLET BOX

HANGER
BRACKET

TAB

OUTLET
BOX

Figure 10

1.

Securely attach the hanger bracket to the outlet
box using the two screws supplied with the outlet
box. (Figure 10.)

2.

Carefully lift the fan and seat the hanger ball/
downrod assembly on the hanger bracket that was
just attached to the outlet box (Figure 11). Be sure
the groove in the ball is lined up with tab on the
hanger bracket (Figure 11).

GROUND
WIRE

LISTED
WIRE
CONNECTOR (3)

GREEN WIRE
(GROUND) FROM
HANGER BRACKET

GREEN WIRE
(GROUND) FROM
HANGER BALL

WHITE SUPPLY
(NEUTRAL)

WHITE FAN
WIRE

BLACK SUPPLY
(HOT)

BLACK AND BLUE
FAN WIRES

Figure 12

NOTE: CEILING COVER
OMITTED FOR CLARITY.

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or
accessories not designated for use with this product
by Emerson Electric Co. could result in personal
injury or property damage.

WARNING

!

Summary of Contents for BUILDER UNIPACK CF701BS00

Page 1: ...s of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered...

Page 2: ...Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted ...

Page 3: ...ach step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted Before assembling your ceiling fan refer to section on proper method of wiring your fan page 7 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Do n...

Page 4: ...g up on the hanger ball securely tighten the two setscrews in the motor coupling Figure 1 NOTE The setscrews must be properly installed as described above or fan wobble could result 5 The fan comes with blue black and white leads that are 42 long Measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of lead...

Page 5: ...ITCH CUP SWITCH CUP CONNECTOR Figure 4 SPRING LOCKWASHER SCREWS SWITCH CUP CONNECTOR WIRE CONNECTORS WHITE WIRES SWITCH HOUSING ASSEMBLY BLACK WIRE NUT FAN SWITCH CHAIN BLUE WIRE LIGHT FITTER BOWL CAP Figure 5 12 Engage the connector of the switch housing assembly with the motor connector Figure 6 The two connectors are keyed and color coded and must be mated correctly color to color before they c...

Page 6: ...U L Model No CF701 15 Install two 60 watt maximum candelabra base light bulbs into the light fitter sockets Figure 8 16 Remove the finial nut and outer bowl cap from the light fitter Figure 8 17 Pass the fan switch chain through the cut slotted hole in the bowl cap Figure 8 To avoid possible fire hazard do not exceed wattage indicated on the fitter WARNING THREADED NIPPLE BOWL CAP LIGHT FITTER OUT...

Page 7: ...ews supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs Use only a U L outlet box listed as Acceptable for Fan Support WARNING OUTLET BOX HANGER BRACKET HANGE...

Page 8: ...ion of the light by gently pulling on the light switch pull chain 3 Check the operation of the fan by gently pulling on the speed control switch pull chain The operation sequence is as follows 1st pull High 2nd pull Medium 4 Your fan is shipped from the factory with the reversing switch positioned to circulate air downward If airflow is desired in opposite direction turn the fan off and wait for t...

Page 9: ...witch position is all the way to one side 2 Fan sounds noisy 1 Blades not attached to fan 1 Attach blades to fan before operating 2 Screws securing fan blade flanges to motor hub 2 Check to make sure the screws which attach the fan are loose flanges to the motor hub are tight WARNING Make sure main power is turned off 3 Wire connectors inside switch housing rattling 3 Check to make sure wire conne...

Page 10: ...763102 ORB 763102 WW 8 Blade Set of 5 763100 13 763100 14 763100 7 Parts Bag Containing 763901 763901 1 763901 2 9 Wire Connector 3 10 Hairpin Clip 1 11 Clevis Pin 1 12 Wood Ball Pendant 2 13 Coupling 2 14 Threaded Stud 8 32 x 1 1 4 2 15 Lockwasher 8 32 2 16 Knurled Knob 8 32 2 17 Screw Flange M6 x 12mm with Lockwasher 11 18 Screw Blade M5 x 6mm 16 19 Wiring Harness 763920 3 763920 2 763920 4 20 F...

Page 11: ...tain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION NAME OF ITEM MODEL NUMBER For repair parts phone 1 800 654 3545 7 8 3 2 10 11 9 17 18 14 1 15 16 19 6 21 13 20 12 22 5 13 12 4 ...

Page 12: ...Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 U L Model No CF701 Form No BP7392 Printed in China 03 09 Part No F40BP73920000 ...