40
100-412-196 REV. 06
Connecting the Tip to the Horn
To attach the tip to the horn, take the following steps:
Figure 5.1
Connecting Tip to Horn
Table 5.12
Connecting the tip to the horn
Step
Action
1
Clean contacting surfaces of the horn and tip, and remove any foreign
matter from the threaded stud and threaded hole.
CAUTION
The tip must be installed clean and dry, or the power supply may not tune
and operate correctly.
2
Hand-assemble the tip to the horn.
3
Using a spanner wrench on the horn and an open-end wrench on the tip,
tighten the tip. See
. Torque specifications for the various
threaded tips follow:
1/4-20 — tighten at 90 inch-lbs./10.16 Newton-meters
3/8-24 — tighten at 180 inch-lbs./20.33 Newton-meters
Summary of Contents for Branson LPX
Page 4: ...iv 100 412 196 REV 06 ...
Page 6: ...vi 100 412 196 REV 06 ...
Page 8: ...viii 100 412 196 REV 06 ...
Page 10: ...x 100 412 196 REV 06 Table 7 2 System Trouble Analysis Chart 73 Table 7 3 Alarms Errors 76 ...
Page 24: ...14 100 412 196 REV 06 ...
Page 33: ...100 412 196 REV 06 23 Chapter 3 Delivery and Handling 3 1 Delivery and Handling 24 ...
Page 38: ...28 100 412 196 REV 06 4 1 4 Declaration of Conformity Figure 4 1 Declaration of Conformity ...
Page 76: ...66 100 412 196 REV 06 ...
Page 85: ...100 412 196 REV 06 75 Figure 7 2 LPX Power Supply Interconnect Diagram ...