(A)
Pressure Gauge (Optional)
(B)
Nitrogen Relief Valve (Optional)
(D)
Isolation Valve (Optional)
(E)
Hydraulic Accumulator With Nitrogen Blanket Charge (Optional)
(H)
Accumulator Isolation Valve (Optional)
(N)
Accumulator Isolation Valve (Optional)
(R)
Pressure Switch
(Q)
Hydraulic Pressure Gauge
(S)
Pressure Transmitter (Optional)
(T)
Check Valve
(V)
Adjustable Flow Controls
(U)
Relief Valve
(O)
Hand Pump Isolation Valve (Optional)
(W)
Bettis G-series Double Acting Actuator
(AB) Pressure Transmitter (Optional)
(J)
Opening Solenoid
(K)
Closing Solenoid
(P)
ESD Solenoid Valve (Optional)
(X)
Shuttle Valve (Optional)
(AC) Shuttle Valve (Optional)
(Y)
Hydraulic Pump
(AD) Accumulator override valve to open (Optional)
(AE) Accumulator override valve to close (Optional)
(Z)
Electric Motor
(AA) Suction Strainer
(I)
Fluid Reservoir
(L)
Hand Pump
(M)
Hand Pump Selection Valves
M
M
L
H
N
W
AD
AE
E
B
A
D
J
X
Y
Z
AA
I
K
O
P
AC
R
Q
T
U
V
S
Installation, Operation and Maintenance Manual
VCIOM-13254-EN Rev. 3
February 2021
27
Section 4: Set-up/Start-up Procedure
Set-up/Start-up Procedure
4.4.3.1
Select and slowly open the Accumulator override Isolation Valve (AD) for
actuator open stroke and (AE) for actuator closing stroke. The Isolation
Valve is in the actuator stroking position when rotated downward to the
horizontal position.
4.4.3.2
After completion of the Accumulator manual override stroke, return the
Isolation Valve (AD) or (AE) to the upward vertical position.
Figure 17
2-Way Remote Electric With Emergency Shutdown Feature Powered
by an Electro-hydraulic power unit
(A)
Pressure Gauge (Optional)
(B)
Nitrogen Relief Valve (Optional)
(D)
Isolation Valve (Optional)
(E)
Hydraulic Accumulator With Nitrogen Blanket Charge (Optional)
(H)
Accumulator Isolation Valve (Optional)
(N)
Accumulator Isolation Valve (Optional)
(R)
Pressure Switch
(Q)
Hydraulic Pressure Gauge
(S)
Pressure Transmitter (Optional)
(T)
Check Valve
(V)
Adjustable Flow Controls
(U)
Relief Valve
(O)
Handpump Isolation Valve (Optional)
(W) Bettis G-series Double Acting Actuator
(AB) Pressure Transmitter (Optional)
(J)
Opening Solenoid
(K)
Closing Solenoid
(P)
ESD Solenoid Valve (Optional)
(X)
Shuttle Valve (Optional)
(AC) Shuttle Valve (Optional)
(Y)
Hydraulic Pump
(AD) Accumulator override valve to open (Optional)
(AE) Accumulator override valve to close (Optional)
(Z)
Electric Motor
(AA) Suction Strainer
(I)
Fluid Reservoir
(L) Handpump
(M) Handpump Selection Valves
MANIFOLD
ESD
MANIFOLD
CLOSE