December 2019
Installation, Operation and Maintenance Manual
MAN-02-05-62-0742-EN Rev. 0
8.3.3
Operating by Directed Mounted Hand Pump
1.
Turn direction valve to “OPEN” or “CLOSE”.
2.
Operate hand pump.
3.
The valve will be stay in position until operated with hand pump again or by
remote control.
Figure 12
8.3.4
Operating by Portable Hand Pump Submerged Actuator
1.
Close the stop valves.
2.
Connect the hoses, via quick connections, A to port A and B to port B.
3.
Select on the hand pump whether to operate towards open or closed.
4.
Pump with the hand pump until the required position is reached.
5.
After operation, open the stop valves.
Figure 13
Instruction plate
Hand pump handle
Direction valve
Stop valve
Quick connector
DPHS block on the control line