background image

Instruction Manual

D104170X012

SV Electric Actuator

July 2017

2

Actuator Specifications

Table 1. Baumann Actuator Specifications

ACTUATOR TYPE

SVX24-MFT

SVK24-MFT

POWER FAILURE

Lock in last position

Fail Open / Fail Closed

ACTION

Direct or Reverse

POWER CONSUMPTION

4 W

8.5 W

TRANSFORMER SIZE

6 VA (class 2 power source)

21 VA (class 2 power source)

TRAVEL

12.7 and 19.1 mm (0.50 and 0.75 inches)

MATERIAL

Housing

Aluminum die cast and plastic casing

YOKE Legs

Aluminum

ENCLOSURE RATING

NEMA 2, / IP 54 UL Enclosure Type 2

INPUT SIGNAL

2 - 10 VDC or 4 - 20 mA input signal

POWER SUPPLY

24 VAC or 24 VDC

ELECTRICAL CONNECTION

3 ft, 18GA appliance cable, 0.5 inch conduit fitting

AMBIENT TEMPERATURE

-30 to 50

_

C (-22 to 122

_

F)

RELATIVE HUMIDITY RANGE

5 to 95% RH, non-condensing

OUTPUT THRUST

1500 N (337 lbf)

VALVE STEM POSITION FEEDBACK OUTPUT

2-10 VDC (0.5 mA maximum)

SHUTOFF CLASS

Class IV or VI per ANSI/FCI 70-2 (Refer to Valve Technical Bulletin)

TRAVEL TIME

35 seconds

NOISE LEVEL

< 45 dB(A)

MANUAL OVERRIDE

4 mm Hex Head

POSITION INDICATION

Travel Indicator on Yoke

SPLIT RANGE CAPABILITY

Yes

AGENCY APPROVALS

CE (A), UL 60730-1A/-2 -14, CSA E60730-1:02 (CE approval for actuator only)

QUALITY STANDARD

ISO 9001

WEIGHT

1.3 kg (2.9 lbs)

1.6 kg (3.6 lbs)

  WARNING

Always wear protective gloves, clothing and eyewear when performing any installation operations to avoid personal
injury.

Personal injury or property damage caused by sudden release of pressure or bursting of pressure retaining parts may result
if service conditions exceed those for which the product was intended. To avoid injury or damage, provide a relief valve for
over pressure protection as required by government or accepted industry codes and good engineering practices.

Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.

If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section  in this
instruction manual.

CAUTION

This actuator is intended for a specific range of pressures, temperatures and other application specifications. Applying
different pressures and temperatures to the actuator could result in parts damage, malfunction of the actuator or loss of
control of the process. Do not expose this product to service conditions or variables other than those for which the product
was intended. If you are not sure what these conditions are you should contact your 

Emerson sales office

 or Local Business

Partner for more complete specifications. Provide the product serial numbers (shown on the nameplate) and all other
pertinent information.

Summary of Contents for Baumann 24000CVF

Page 1: ...ann sliding stem control valves Scope of Manual This instruction manual includes installation maintenance and parts information for Baumann SV electric actuators Do not install operate or maintain Baumann SV electric actuators without being fully trained and qualified in valve actuator and accessory installation operation and maintenance To avoid personal injury or property damage it is important ...

Page 2: ... 9 lbs 1 6 kg 3 6 lbs WARNING Always wear protective gloves clothing and eyewear when performing any installation operations to avoid personal injury Personal injury or property damage caused by sudden release of pressure or bursting of pressure retaining parts may result if service conditions exceed those for which the product was intended To avoid injury or damage provide a relief valve for over...

Page 3: ...s pressure or bursting of parts Before performing any maintenance operations D Do not remove the actuator from the valve while the valve is still pressurized D Always wear protective gloves clothing and eyewear when performing any maintenance operations D Disconnect any operating lines providing air pressure electric power or a control signal to the actuator Be sure the actuator cannot suddenly op...

Page 4: ...ition Equipment damage may occur from liquids leaking into the actuator cover Note Assembly can be mounted horizontally or vertically Do not install with the actuator below the pipe Figure 2 Baumann Actuator Parts Table 2 Baumann Actuator Assembly Parts List Key No Key No Qty 12 7 mm 1 2 inch TRAVEL 19 1 mm 3 4 inch TRAVEL Part Number Part Number 17 Actuator Yoke 1 Consult your Emerson sales offic...

Page 5: ... valve stem Finger tighten both nuts down as far as possible Lock the nuts together using two wrenches to counter tighten them By turning the locked nuts with a wrench you will be able to turn the valve stem in step 8 without damaging the surface of the valve stem CAUTION When assembling or disassembling the valve do not turn the valve stem while the plug is touching the valve seat This will damag...

Page 6: ...tup information please visit http www belimo us ishop cms sh mftpctool index html The calibration PC tool as well as MFT documentation is available SV Manual Override SV Manual Override Y2A7087 TURN MANUAL OVERRIDE COUNTERCLOCKWISE ACTUATOR PLUNGER RETRACTS TURN MANUAL OVERRIDE CLOCKWISE ACTUATOR PLUNGER EXTENDS USE 4 mm HEX E1354 ...

Page 7: ...ber When ordering replacement parts also specify the key number and part name shown in table 2 WARNING Use only genuine Fisher replacement parts Components that are not supplied by Emerson Automation Solutions should not under any circumstances be used in any Fisher valve because they may void your warranty might adversely affect the performance of the valve and could cause personal injury and pro...

Page 8: ...are available upon request We reserve the right to modify or improve the designs or specifications of such products at any time without notice E 2016 2017 Fisher Controls International LLC All rights reserved Baumann and Fisher are marks owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co Emerson Automation Solutions Emerson and the Emerson logo a...

Reviews: