7
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF921
3. Ceiling Fan Assembly
(continued)
10.
The blade flanges have an interlocking feature that
must be fully engaged before tightening the screw.
Make sure all the flanges are properly engaged and
then tighten the flange screws. If one of the flanges
does not seat properly on the motor hub, loosen the
adjacent flange screws, re-engage and reseat the
flanges, then tighten the screws again.
11.
Remove the four switch housing mounting screws
(Figure 7) from the switch housing plate. Position
the switch housing assembly on the switch housing
plate and align the holes in the switch housing
assembly with the holes in the plate. Secure the
switch housing assembly by installing the four
screws (Figure 7).
NOTE: Tuck in both the blue and white wires
carefully under the switch housing cover
SWITCH
HOUSING
ASSEMBLY
MOUNTING
SCREWS (4)
Figure 7
To reduce the risk of personal injury, do not bend the
blade flange when installing the blade flanges,
balancing the blades or cleaning the fan. Do not insert
foreign objects in between rotating fan blades.
WARNING
!
12.
You have now completed the assembly of your new
ceiling fan. You can now proceed with hanging and
wiring your fan.
Please call Emerson technical support at
1-800-654-3545 if you have any questions
about installation and operation of this ceiling fan.
AT LEAST
7'
CEILING
FLOOR
Figure 8
TWO SCREWS
SUPPLIED WITH
OUTLET BOX
HANGER
BRACKET
TAB
OUTLET
BOX
Figure 9
4. How to Hang Your Ceiling Fan
The outlet box and joist must be securely mounted and
capable of supporting at least 50 lbs. Use only a U.L.
outlet box listed as “Acceptable for Fan Support of
22.7kg. (50 lbs.) or less”.
WARNING
!
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked “Acceptable for
Fan Support of 22.7kg. (50 lbs.) or less”, and use
screws supplied with outlet box. Most outlet boxes
commonly used for support of light fixtures are not
acceptable for fan support and may need to be
replaced. Consult a qualified electrician if in doubt.
WARNING
!
The fan must be hung with at least 7' of clearance from
floor to blades (Figure 8).
WARNING
!
1.
Securely attach the hanger bracket to the outlet box
using the two screws supplied with the outlet box.
(Figure 9.)
NOTE: CEILING COVER
OMITTED FOR CLARITY.
Summary of Contents for AVANT ECO CF921VNB
Page 18: ...18 ETL Model No CF921 Notes ...