Table 8-11 Holdup Cap Volts
Feature
Raw Value
Description
Sensor Name
Holdup Cap Volts
-
Sensor LUN
0x00
-
Sensor Number
0x06
-
Entity ID
0x0A
Power Supply
Sensor Type
0x02
Voltage
Event/Reading Type
0x01
Threshold
Assertion Event Mask
(Byte 15)
0x14
Assertion Event Mask
(Byte 16)
0x6A -
Deassertion Event Mask
(Byte 17)
0x14 -
Deassertion Event Mask
(Byte 18)
0x6A -
Threshold Mask (Byte 19) 0x36
-
Threshold Mask (Byte 20) 0x36
-
Base Unit
0x04
Volts
Rearm mode
0x01
Auto
Hysteresis Support
0x01
Readable
Threshold Access
Support
0x02
Readable and settable
Event Message Control
0x00
Per Threshold/Discrete
State
Nominal Reading
0xE4
90
Upper non-recoverable
threshold
0xFF
101
Upper critical threshold
0xFA
99