background image

 

Installation, Operation and Maintenance Manual

D104482X012 

5

Section 3: Installation 

Asset Management Tags can be ordered as an accessory to be installed on an assembly or 
can be purchased for existing in-field equipment to be populated utilizing Asset Connect 
software or with the support of your Emerson sales office and service center.

If the Asset Management Tag assembly is being installed on process equipment in the field, 
observe all installation warnings, cautions, and notes provided in the Instruction Manuals 
for all applicable equipment.

Figure 3 

Asset Management Tag Assembly 

     WARNING

Avoid personal injury or damage to property from sudden release of pressure or 
uncontrolled process fluid. Before starting installation on, or removal from, existing in-field 
equipment:

• 

Always wear protective gloves, clothing, and eyewear when performing any 
installation or removal operations to avoid personal injury.

• 

Follow all warnings, cautions, notes, and instruction procedures provided in the 
Instruction Manuals for all applicable equipment to ensure hazardous conditions 
are not created. 

• 

If mounting onto or removing from a valve, use bypass valves or completely shut 
off the process to isolate the valve from process pressure. Relieve process pressure 
on both sides of the valve. Drain the process media from both sides of the valve.

• 

If mounting onto or removing from an actuator casing, vent the power actuator 
loading pressure. 

• 

If mounting onto or removing from other equipment containing process pressure 
or process fluid, relieve and isolate the equipment from process pressure and drain 
process media.

• 

Use lock-out procedures to be sure that the above measures stay in effect while 
you work on the equipment.

• 

Check with your process or safety engineer for any additional measures that must 
be taken to protect against process media.

Installation 

Section 3: Installation

May 2019

Summary of Contents for Asset Management Tag

Page 1: ...Installation Operation and Maintenance Manual D104482X012 Asset Management Tag ...

Page 2: ......

Page 3: ...escription 2 1 3 Specifications 3 1 4 Education Services 3 Section 2 Device Information Section 3 Installation 3 1 Mounting Considerations 6 3 2 Installing a Casing Mounted Asset Management Tag 7 3 3 Installing a Yoke Mounted Asset Management Tag 8 3 4 Installing a Universal Mounted Asset Management Tag 8 Section 4 Related Documents Section 5 Parts Ordering Section 6 Kits ...

Page 4: ...t Quick Start Guide for information on how to use this downloadable application as well as information on requirements for the reader writer and PC or tablet Do not install operate or maintain an Asset Management Tag without being fully trained and qualified in valve actuator valve accessory and other applicable process equipment installation operation and maintenance To avoid personal injury or p...

Page 5: ...nter A reader writer device is needed to communicate with the Asset Management Tag using UHF RFID wireless technology Information gathered from the Asset Management Tag which has been read by the reader writer will then be shared to the Asset Connect Software on either a PC or Tablet using Bluetooth wireless technology 1 Asset Management Tag 2 Reader Writer Reader Writer not available for sale fro...

Page 6: ...niversal Minimum Read Write Range Distance 20 ft 6 09 m read range 1 ft 0 30 m write range Range dependent on reader writer selected Hazardous Area Approvals FM US Canada Intrinsically Safe refer to D104401X012 ATEX Intrinsically Safe refer to D104402X012 IECEx Intrinsically Safe refer to D104403X012 Electrical Classifications Type 4X IP68 Other Standards UHF EPC Class 1 Gen 2 ISO IED 18000 6C GS1...

Page 7: ...ual D104482X012 4 Device Information Section 2 Device Information May 2019 Section 2 Device Information Available fields for stored information on the Asset Management Tag are shown below in figure 2 Figure 2 Asset Management Tag Storage Fields ...

Page 8: ...rforming any installation or removal operations to avoid personal injury Follow all warnings cautions notes and instruction procedures provided in the Instruction Manuals for all applicable equipment to ensure hazardous conditions are not created If mounting onto or removing from a valve use bypass valves or completely shut off the process to isolate the valve from process pressure Relieve process...

Page 9: ...mize read range as well as provide mounting flexibility onto a wide range of equipment reference table 2 for assembly part numbers 3 1 Mounting Considerations Installation of the Asset Management Tag assembly must take into consideration line of sight when using the reader writer to communicate To avoid negatively impacting the read write distance the Asset Management Tag assembly should not be ob...

Page 10: ...nt below the lower casing with the bracket pointed downward and facing outward Reference figures 3 and 4 above 3 Ensure that mounting of the Asset Management Tag does not prevent full thread engagement of the casing bolting If mounting the tag prevents complete thread engagement mount using a longer casing bolt of the same material specification 4 Ensure casing bolt is tightened per torque specifi...

Page 11: ...olt through the top and follow with washer and nut on the bottom side of the auxiliary bracket and tighten 3 4 Installing a Universal Mounted Asset Management Tag 1 Review Mounting Considerations when planning installation location of Asset Management Tag 2 Install auxiliary bracket to equipment with user supplied wire or strap Install Asset Management Tag assembly to the mounted auxiliary bracket...

Page 12: ...f the product and could cause personal injury or property damage Section 6 Kits The Asset Management Tag is pre affixed to the bracket and must remain installed as an assembly for optimal read range and ease of installation for all three mounting styles Reference the installation section of this manual for additional details NOTE Contact your Emerson sales office for part ordering information Tabl...

Page 13: ...94X012 50 50i 70 70i 87 80 GE89296X012 100 GE89297X012 685 685SE SR 12 26 GE89293X012 Universal 1061 All GE89292X012 Yoke 2052 1 GE89299X012 Casing 2 3 GE91686X012 3025 P460 GE91686X012 P462 P462 200 P900 Baumann 16 GE94806X012 32 GE89298X012 54 70 GE91686X012 SV GE89293X012 Universal D3 All pneumatic GE94805X012 Casing D4 easy Drive All GE89291X012 FieldQ All GE89293X012 Universal Bettis G Series...

Page 14: ...nted for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability All sales are governed by our terms and conditions which are available on request We reserve the right to modify or improve the designs or specificatio...