background image

READ AND SAVE THESE INSTRUCTIONS

AMERICA’S FAN COMPANY

®

52" “APOLLO” Series

Model No.

CF3900WW01

CF3900AW01

CF3900AB01

CF3900PB01

CF3900WPB01

CF3900OB01

CF3900HTW01

CF3900BS01

CF3900BQ01

CF3900TG01

CF3900CK01

“APOLLO” Series

Ceiling Fan Owner's Manual

Net Weight:  

18.0

Lbs.

Part No. F40BP72340003

Form No. BP7234-3

Summary of Contents for APOLLO CF3900AB01

Page 1: ...ANY 52 APOLLO Series Model No CF3900WW01 CF3900AW01 CF3900AB01 CF3900PB01 CF3900WPB01 CF3900OB01 CF3900HTW01 CF3900BS01 CF3900BQ01 CF3900TG01 CF3900CK01 APOLLO Series Ceiling Fan Owner s Manual Net Weight 18 0 Lbs Part No F40BP72340003 Form No BP7234 3 ...

Page 2: ...vice center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty...

Page 3: ...cian 3 The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt ...

Page 4: ...ff boxes are provided next to each step As each step is com pleted place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted CEILING COVER FOAM PACKING PROTECTIVE PLASTIC BAG FOAM PACKING CARTON MOTOR AND HOUSING ASSEMBLY HANGER BALL DOWNROD ASSEMBLY HANGER BRACKET LOOSE PARTS BAG BLADE FLANGES MOTOR COVER ...

Page 5: ...r Slide the motor cover over the downrod and rotate the cover until the threaded studs protrude install two knurled knobs supplied to secure the cover NOTE Make sure the red and brown leads are capped with wire connectors and are completely inside motor cover and not pinched between the motor cover and motor 7 Position the ceiling cover over the downrod Be sure the cover is oriented correctly with...

Page 6: ...so that the bottom of the motor is facing you Engage the connector of the switch cup assembly with the motor connector by aligning the V notch shaped keyways and pressing the connectors firmly together until they fully mate The V notch keyways prevent the connectors from being engaged improperly 14 Position the switch cup assembly on the motor switch plate and align the holes in the cup assem bly ...

Page 7: ...uld wobble or fall WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard WARNING To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box...

Page 8: ...et box is ground ed contact a licensed electrician for advice as it must be grounded for safe operation WARNING Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result WARNING 5 Secure the ceiling cover in place by sliding lock washe...

Page 9: ...1 Ceiling Fan Light Kits see store or catalog 2 Ceiling Fan Light Controls see store or catalog 3 Downrod Extension Kits see store or catalog This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or acces sories not designated for use with this product by Emerson ...

Page 10: ... 21 22 9 10 7 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION NAME OF ITEM MODEL NUMBER THE PART NUMBER THE PART DESCRIPTION For repair parts phone 1 800 654 3545 10 ...

Page 11: ...61621 9 761621 12 761621 15 761621 19 761621 13 761621 20 761621 22 23 Motor 762304 762304 762304 762304 762304 762304 762304 762304 762304 762304 762304 Parts Bag containing 762020 762020 1 762020 762020 762020 1 762020 762020 2 762020 1 762020 1 762020 762020 4 Pin Clevis 1 5 Clip Hairpin 1 11 Coupling 1 12 Pendant 1 14 Wire Connector 3 15 Wrench Hex 3 16 1 16 Stud Threaded 1 1 4 2 17 Lockwasher...

Page 12: ...e wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing 6 Screws holding blades to flanges are loose 6 Tighten screws securely WARNING Make sure main power is turned off 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Tighten the setscrew in the motor coupling excessively 2 Setscrew in hanger ball downrod assembly is 2 Tighte...