Insert the unit with the seal into the sleeve pushing it all the way to rear making sure the seal are against the rear 
grille. The seals are necessary to reduce recirculation of hot air into the intakes which would reduce system 
performance.

An option is to purchase 3/4'' diamond cut aluminum grille and cut it to fit inside the sleeve. Secure it with screws.
Attach the dual intake grill directly to the back of the unit. Slide the entire unit into the sleeve and seal with the 
stuffing seal supplied with the kit.

Trim Kit Installation Instructions
1. Install the 1''x1''x84'' long stuffer seal between the wall sleeve and the unit. A flat-bladed screwdriver or putty 
    knife is needed.
2. Assemble the trim frame by inserting the top and bottom pieces into side pieces and snapping into place.
3. Pull the cord through the trim frame and slide the trim over the unit until flush with the wall.

Energy saving suggestion: In order to reach the maximum energy saving and comfortable, it is necessary to 
use an appropriately sized cover to provide additional insulation and air sealing when the unit is not in use 
during the off-using-season.

Summary of Contents for EBTC08RE1T

Page 1: ...MODEL EBTC08RE1T EBTC10RE1T EBTC10RE2T EBTC12RE1T EBTC12RE2T EBTC12RD2T EBTE14RRDT THRU THE WALL AIR CONDITIONER ...

Page 2: ......

Page 3: ......

Page 4: ...N IMPORTANT SAFETY INSTRUCTION PACKING LIST INSTALLATION ASSEMBLY INSTRUCTIONS USING YOUR AIR CONDITIONER CARE AND CLEANING TROUBLESHOOTING ELECTRICAL REQUIREMENTS OPERATING YOUR AIR CONDITIONER 1 2 3 4 8 10 11 12 ...

Page 5: ...1 ...

Page 6: ...2 8K 10K 12K 14K Cooling 8K Cooling Heating 10K 12K 14K Cooling Heating ...

Page 7: ... Trim Frame 2 Top Bottom legs Grille Aluminum Rear plastic net PAPT QUANTITY IMAGE PAPT QUANTITY Dimension Seal sponge 1 x3 4 x14 2 Seal sponge 1 x3 8 x14 2 Seal sponge 1 x3 8 x25 3 Seal sponge 1 x1 1 2 x25 3 Seal sponge 1 x1 1 2 x14 2 Seal sponge 1 x1 1 2 x84 1 Seal cotton 3 3 4 x1 1 2 x4 4 Seal cotton 3 4 x1 1 2 x17 2 4 1 1 1 2 2 1 1 or ...

Page 8: ...placement installations a Frigidaire Sleeve Kit EA108T is recommended CAUTION When installation is complete replacement unit must have rearward slope as shown in Fig 1 2 Remove old Air Conditioner from wall sleeve and prepare as followings Clean interior Do not disturb seals Check the wall sleeve be securely fastened in wall before installing Add more nails or screws if needed Repair painted surfa...

Page 9: ...below pictures Remove the existing grille and save the mounting screws Place the grille included with your new air conditioner towards the inside rear of the sleeve Attach the new grille by aligning the four mounting holes Re insert the self tapping screws into the nylon retainers 2 Grille Remove Important Single intake grille must be removed when used with dual intake TTW unit Warning When removi...

Page 10: ...the top of the unit The overhang on each side is equal 4 If the unit has not been predrilled some model carefully drill 4 1 8 holes through the grille and into the side flange of the unit approximately 1 1 2 to 2 from the top and bottom as Fig 2 or 3 Be careful not to break the copper pipe 5 Install 4 8 self tapping screws to affix the grille to the unit 6 Insert the unit into the sleeve Grille to...

Page 11: ...ration instruction 2 Before sliding unit all the way back remove second screw from left side of unit 3 Remove plastic washer from screw 4 Screw the other end of the ground wire into the unit as shown Make sure the toothed washer is against the cabinet 5 Slide unit completely to the rear Non Frigidaire Dual Intake Grille In case where the existing sleeve is a non Frigidaire sleeve but is installed ...

Page 12: ...d seal with the stuffing seal supplied with the kit Trim Kit Installation Instructions 1 Install the 1 x1 x84 long stuffer seal between the wall sleeve and the unit A flat bladed screwdriver or putty knife is needed 2 Assemble the trim frame by inserting the top and bottom pieces into side pieces and snapping into place 3 Pull the cord through the trim frame and slide the trim over the unit until ...

Page 13: ...ove The SET light will turn on while setting To cancel the setted function press the TIMER button again 5 Timer Button Cool Mode The cooling function allows the air conditioner to cool the room and at the same time reduces Air humidify Press the MODE button to activate the cooling function To optimize the function of the air conditioner adjust the temperature and the speed by pressing the button i...

Page 14: ...30 60 minutes and at most change six times until the set temperature is 28 For heating mode the set temperature will automatically decrease by 1 every 30 60 minutes and at most change six times until the set temperature is 24 And every running time depends on the set temperature 7 Sleep Button Press the FAN SPEED button to choose the fan speed options You can choose Hi Med Lo or auto speed in COOL...

Page 15: ...he display of the machine Note It can be set to automatically turn off or on in 0 5 24 hours Each press of the buttons will increase or decrease the timer The Timer can be set in 0 5 hours increment below 10 hours and 1 hour increment for 10 hours or above The SET light will turn on while setting To cancel the setted function press the TIMER button again 5 Timer In AUTO mode the unit automatically...

Page 16: ...11 FIG 21 FIG 21 ...

Page 17: ...12 ...

Page 18: ...13 For any questions or Technical Support Please Call Customer Service 1 844 801 8880 ...