Installation Instructions
Site Instructions
Site for Installing Outdoor Unit
Where it is convenient to install and well ventilated.
Avoid installing it where flammable gas could leak.
Keep the required distance apart from the wall.
Keep the outdoor unit away from greasy dirt, vulcanization gas exit.
Avoid installing it by the roadside where there is a risk of muddy
water.
A fixed base where it is not subject to increased operation noise.
Where there is not any blockage of the air outlet.
Avoid installing under direct sunlight, in an aisle or sideway,
or near heat sources and ventilation fans. Keep away from
flammable materials, thick oil fog, and wet or uneven places.
If the height or pipe length is out of the scope of the table, please consult the merchant.
Model
9K-18K
20
Required amount of
additional refrigerant (g/m)
24K
30K-36K
30
40
In case the pipe length is more than 7.5m(24.6ft), the refrigerant should be charged additionally, according
to below table.
Outdoor unit
Indoor unit
Pipe length is
20 meters(65.4ft) Max.
be less than 5m (16.4ft)
Height should
Outdoor unit is higher than indoor unit
Installation of indoor unit refers to the indoor unit installation manual
.