- 10 -
The hot air exhaust hose is not connected
or blocked.
Connect or clean the hot air exhaust
hose.
Temperature setting is too high.
Reset the temperature.
Air inlet is blocked.
Clean the air inlet.
Noisy
The ground is not level or not flat enough.
Place the appliance on a flat, level
surface if possible.
The sound comes from the flowing of the
refrigerant inside the appliance.
It is normal.
E0 Code
Room temperature sensor failed.
Replace the room temperature sensor.
Contact authorized service technician
for repair.
E1 Code
Condenser temperature sensor failed.
Replace condenser temperature sensor.
Contact authorized service technician
for repair.
E2 Code
Water tank full when cooling.
Take off the rubber stopper and empty
the water.
E3 Code
Evaporator temperature sensor failed.
Replace evaporator temperature sensor.
Contact authorized service technician
for repair.
TECHNICAL DATA
Notice: Operation temperature range:
Maximum cooling
Minimum cooling
Dry bulb temperature /
Wet bulb temperature(
℃
)
35/24
18/12
Below data for your operating reference
Model
PAC-122838
PAC-122839
Rated voltage
220-240V
220-240V
Rated frequency
50Hz
50Hz
Rated input
785W
1000W
Rated current
3.5A
4.5A
Cooling capacity
2050W
(7000Btu/h)
2600W
(9000Btu/h)
Moisture removal (L/H)
0.8
1.0
Air flow
320m³/h
320m³/h
ERP INFORMATION
Value
Value
Trademark
Emerio
Emerio
Model identification
PAC-122838
PAC-122839
Sound power (cooling)
≦
65dB(A)
≦
65dB(A)
Name of refrigerant
R290 (0.14kg)
R290 (0.16kg)
Rated power input for cooling (kW)
0.785
1.0
Rated energy efficiency ratio
2.6
2.6
GWP (kgCO
2
eq)
3
3
Energy efficiency class
A
A