EES-501 Ultrasonic Flowmeter
Reversion: 3.0.1
Page 41 of 51
Segment Facter
You need to input the password "115800", then press
key to expand. Expand only in the current
period, automatically shut down when the power is cut
off. You can set 16 groups correction coefficient for
sectionally correcting measurement results. The user
can input the actual scale factor, referring to the
calibration results.
Current Loop Mode Select
0.
4-20mA flow;
1.
4-20mA Velocity.
CL 4mA Output Value
Set the CL output value according to the flow value at
4mA. The flow unit
’
s options are as same as those in
Window M31. Once "velocity 4-20mA"is selected in
Window M55, the unit should be set as m/s if it is the
velocity unit selected.
20mA Output Value
Set the CL output value according to the flow value at
20mA. The flow unit is the as same as that found in
Window M31. Once "velocity 4-20mA"is selected in
Window M55, the unit should be set as m/s, if m/s is
the velocity selection.