(3) Using pliers, bend the solid wire to form a loop suitable for the terminal screw.
(4) Shape the loop wire properly, place it on the terminal block an tighten securely with the terminal screw using a
screwdriver.
For standing wiring
(1) Cut the wire with a wire cutter or wire-cutting pliers, then strip the insulation to about
3
/
8
"(10mm) of expose the
stand wiring.
(2)
!
Using a screwdriver, remove the terminal screw(s) on the terminal block.
(3) Using a round terminal fastener or pliers, securely clamp a round terminal to each stripped wire end.
(4) Position the round terminal wire, replace and tighten terminal screw by using a screwdriver.
ELECTRICAL REQUIREMENT
For wire size and fuse table shows you as following below
Model
Supply cord (mm
2
)
Indoor to Outdoor cord (mm
2
)
phase
Fuse capacity (A)
7,000-12,000 Btu/h
2.5
1.5
1
10
18,000 Btu/h
2.5
1.5
1
15
24,000 Btu/h
4
1.5
1
20
30,000-36,000 Btu/h
6
1.5
1
25
48,000 Btu/h
4
1.5
3
15
56,000-60,000 Btu/h
6
1.5
3
20