3
ELECTRICAL SAFETY INSTRUCTIONS
1. Read & follow all safety instructions.
2. A green colored terminal or a terminal marked G, GR, Ground, Grounding, or the international symbol is located inside the supply
terminal box or compartment. To reduce the risk of electric shock, this terminal must be connected to the grounding means
provided in the electric supply panel with a continuous copper equivalent in size to the circuit conductors supplying this
equipment.
3. The equipment must be provided with a ground fault circuit interrupter located in the disconnect switch, as installed by a licensed
electrician.
4. The electrical service panel should be equipped with a 20-amp switch.
5. The electrical supply for the spa must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors,
to comply with section 422-30 of the National Electrical Code, ANSI/NFPA 70-2002. The disconnecting means must be readily
accessible to the spa occupant, but must not be within 5 feet (1.52 m) of the spa.
6. All field-installed metal components such as rails, ladders, drains or other similar hardware within 3 meters of the spa shall be
bonded to the equipment grounding bus with copper wire conductors not smaller than No. 6 AWG.
7. For units intended for use other than single family dwellings, a clearly labeled emergency switch shall be provided as part of the
installation. The switch shall be readily accessible to the occupants and shall be installed at least 5 feet (1.52 m) away, adjacent
to, and within sight of, the unit
8. WARNING: Improper electrical connections or conductor sizing may cause the equipment module to operate improperly, create
the potential for an electrical hazard, and may void the warranty.
9. CAUTION: Use only approved pressure-type wire splicing lugs or connectors suitable for the size and type of wiring used.
If your hot tub is equipped with audio components, the following instructions also apply:
1. CAUTION - Risk of Electric Shock. Do not leave component access panel open.
2. CAUTION - Risk of Electric Shock. Replace components only with identical components.
3. CAUTION - Do not operate the audio components while inside the spa.
4. WARNING - Prevent Electrocution. Do not connect any auxiliary components (for example cable, additional speakers,
headphones, additional audio/video components, etc.) to the system.
5. These units are not provided with an outdoor antennae; when provided, it should be installed in accordance with Article 810 of the
National Electrical Code, ANSI/NFPA 70.
6. Do not service this product yourself as opening or removing covers may expose you to dangerous voltage or other risk of injury.
Refer all servicing to qualified service personnel.
7. If the power supply connections or power supply cord(s) are damaged; if water is entering the audio equipment compartment
area; if the protective shields or barriers are showing signs of deterioration; or if there are signs of other potential damage to the
unit, turn off the unit at the disconnect switch and refer servicing to qualified service personnel.
8. This unit should be subjected to periodic routine maintenance (for example, once every 3 months) to make sure that the unit is
operating properly.
9. Replace damaged cord immediately.
10. Do not bury electrical cables or cords.