ELECTRICAL  SAFETY  INSTRUCTIONS 

 
1.  Read & follow all safety instructions.

 

 

2.  A green colored terminal or a terminal marked G, GR, Ground, Grounding, or the international symbol is located inside the supply 

terminal  box  or  compartment.  To  reduce  the  risk  of  electric  shock,  this  terminal  must  be  connected  to  the  grounding  means 

provided  in  the  electric  supply  panel  with  a  continuous  copper  equivalent  in  size  to  the  circuit  conductors  supplying  this 

equipment.

 

 

3.  The equipment must be provided with a ground fault circuit interrupter located in the disconnect switch, as installed by a licensed 

electrician.  

4.  The electrical service panel should be equipped with a 20-amp switch.   
5.  The electrical supply for the spa must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors, 

to comply with section 422-30 of the National Electrical Code, ANSI/NFPA 70-2002.  The disconnecting means must be readily 

accessible to the spa occupant, but must not be within 5 feet (1.52 m) of the spa. 

6.  All field-installed metal components such as rails, ladders, drains or other similar hardware within 3 meters of the spa shall be 

bonded to the equipment grounding bus with copper wire conductors not smaller than No. 6 AWG.

 

 

7.  For units intended for use other than single family dwellings, a clearly labeled emergency switch shall be provided as part of the 

installation. The switch shall be readily accessible to the occupants and shall be installed at least 5 feet (1.52 m) away, adjacent 

to, and within sight of, the unit

 

 

8.  WARNING:  Improper electrical connections or conductor sizing may cause the equipment module to operate improperly, create 

the potential for an electrical hazard, and may void the warranty.  

9.  CAUTION:  Use only approved pressure-type wire splicing lugs or connectors suitable for the size and type of wiring used.   

 

If your hot tub is equipped with audio components, the following instructions also apply: 

1.  CAUTION - Risk of Electric Shock. Do not leave component access panel open.

 

 

2.  CAUTION - Risk of Electric Shock. Replace components only with identical components.

 

 

3.  CAUTION - Do not operate the audio components while inside the spa.

 

 

4.  WARNING  -  Prevent  Electrocution.  Do  not  connect  any  auxiliary  components  (for  example  cable,  additional  speakers, 

headphones, additional audio/video components, etc.) to the system.

 

 

5.  These units are not provided with an outdoor antennae; when provided, it should be installed in accordance with Article 810 of the 

National Electrical Code, ANSI/NFPA 70.

 

 

6.  Do not service this product yourself as opening or removing covers may expose you to dangerous voltage or other risk of injury. 

Refer all servicing to qualified service personnel.

 

 

7.  If  the  power supply  connections  or  power  supply  cord(s)  are  damaged;  if  water is  entering  the  audio  equipment compartment 

area; if the protective shields or barriers are showing signs of deterioration; or if there are signs of other potential damage to the 

unit, turn off the unit at the disconnect switch and refer servicing to qualified service personnel.

 

 

8.  This unit should be subjected to periodic routine maintenance (for example, once every 3 months) to make sure that the unit is 

operating properly.

 

 

9.  Replace damaged cord immediately.

 

 

10.  Do not bury electrical cables or cords.

 

 

 

Summary of Contents for Energize EM5

Page 1: ...Owner s Manual 2012 Important Information Enclosed Please read before setting up or using your spa Rev 1 1 12 MODELS EM5 EM6...

Page 2: ...o use this product unless they are closely supervised at all times 8 A wire connector is provided on this unit to connect a minimum No 8 AWG 8 4mm2 solid copper conductor between this unit and any met...

Page 3: ...WARNING Improper electrical connections or conductor sizing may cause the equipment module to operate improperly create the potential for an electrical hazard and may void the warranty 9 CAUTION Use o...

Page 4: ...ed on a solid flat and level surface that does not move or shake 7 You should consult with a builder or engineer to determine if your floor will support the spa weight Remember you must allow for the...

Page 5: ...ectrical Code N E C and local code requirements The connection must include the conductors necessary for operation and bonding as required by N E C 1 Remove the spa from its shipping container and ret...

Page 6: ...ent module area for water leaks If there is water dripping it is probably a loose connection at the equipment module You should re check the tightness of the fittings and placement of the O rings Chec...

Page 7: ...ou must properly test and maintain your spa water for health and appearance reasons Chemical imbalance can cause skin irritations and dirty water is both unsightly and undesirable to soak in With litt...

Page 8: ...e surface Bug Tar Remover or OOPS Do not use an abrasive brush or cleaning agent as it will scratch the finish DO NOT USE any of the following items to clean your tub Acetone Goof Off or any cleaners...

Page 9: ...sure that the thermostat is set to keep the water warm If you intend on closing down your spa for the winter you should follow the winterizing procedures listed below 1 Drain the spa as explained in t...

Page 10: ...ng for at least 2 minutes Your spa will enter Priming Mode when it is energized During Priming Mode press Jets button repeatedly and be sure the pump is free of air Priming Mode lasts less than 5 minu...

Page 11: ...rrent water temperature will be displayed DO NOT ENTER THE WATER Remove the spa cover and allow water to cool Once the heater has cooled reset by pushing any button If spa does not reset shut off the...

Page 12: ...l hot water coming from the jets Make sure all valves are open to allow full water flow through the system Limited water flow will NOT build enough pressure to allow the heater to come on Clean the fi...

Page 13: ...________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ________...

Page 14: ...an 49512 phonenumber 800 766 7727 for packaging and shipping instructions In addition Emerald reserves the right to inspect or designate a person to inspect any part that is claimed to be defective an...

Page 15: ...years unless otherwise excluded as described above from initial start up of spa and labor is not included on such parts notwithstanding anything above to the contrary The stainless steel escutcheon o...

Reviews: