ASSEMBLY 

Failure to follow these instructions may result in injury and  

equipment damage/malfunction.

1.   Smoke alarm/s must be installed by a licensed electrician.
2.  All interconnected smoke alarms must be supplied from the  

same circuit.

3   A common neutral must be used for the interconnect to operate.
4.  DO NOT connect the interconnect wire to active or neutral.
5.   

A maximum of 40 smoke alarms can be installed on one 

 

circuit (wired interconnection only).

6.   Alarm will not attach to mounting bracket unless battery is installed 

correctly.

Warning: 

This smoke alarm is not suitable for wall (vertical)  

mounting.  

LOCATION OF SMOKE ALARMS

For maximum protection smoke alarms should be installed in 

 

every room (except  areas described in the previous section 

 

‘Locations to Avoid’) to ensure people in the home will be able to hear 

and respond to the alarm. At the very least install one smoke alarm on 

every floor.

If you suspect a household member may not hear this smoke alarm 

i.e. outdoor or indoor noise, sound sleepers, drug or alcohol usage, 

the hard of hearing, etc install and maintain a specialty smoke alarm 

device.

NOTE: In Australia each state has a different legislation when it comes 

to smoke alarms. Please visit the relevant authority in your state for 

specific legislation requirements.

LOCATIONS TO AVOID 

1.  

Don’t place alarms in bathrooms, kitchens, garages or 

 

other rooms where the alarm may be triggered by steam, 

 

condensation and normal smoke/heat from appliances.

2.   

In areas with high humidity, like bathrooms or areas near 

dishwashers or washing machines, install at least 3m away from 

these areas.

3.  Near air returns or heating and cooling supply vents, install  

at least 1m away from these areas. The air could blow smoke away 

from the detector, interrupting its alarm.

4.  In rooms where the temperature may fall below 0°C or rise above 

40°C (due to nuisance/false alarm activation). 

5.  

In extremely dusty, dirty, or insect infested areas where 

 

particles may interfere/obstruct with Alarm operation. 

6. Away from air conditioning or ventilation grilles/louvers.

TYPICAL MULTI-STORY OR SPLIT LEVEL HOME

For maximum protection, a smoke alarm should be installed on the 

ceiling of each bedroom, living area, and hallway. Where a hallway 

is more than 10 meters long install a smoke alarm at each end. Also 

install a smoke alarm above each staircase.
For minimum protection, a smoke alarm should be installed above 

each staircase, including the basement.

POSITION OF SMOKE ALARMS

Smoke will spread horizontally after rising to the ceiling, so it’s  

advisable to install the smoke alarm in the centre of the ceiling where 

possible. Avoid areas where there is no circulation.

•  

When mounting an alarm on the ceiling, locate it a minimum of 

30cm from the side wall.

• 

 Install smoke alarm/s on slopped, peaked or cathedral ceilings  

between 50cm and 250cm from the highest point of the ceiling.

TYPICAL SINGLE-STORY HOME

For maximum protection, a smoke alarm should be installed on the 

ceiling of each bedroom, living area, and hallway. Where a hallway is 

more than 10 meters long install a smoke alarm at each end. If there 

is a basement install a smoke alarm on the basement ceiling at the 

bottom of the stairwell.
Additionally, a smoke alarm should be installed in the hallway  

between the living areas (incl. kitchen) and bedrooms. Place it as near 

to the living areas as possible and ensure the smoke alarm is audible 

when bedrooms are occupied. 

LIVING ROOM

BATH

KITCHEN

BEDROOM

BEDROOM

BEDROOM

BEDROOM

FAMILY ROOM

BEDROOM

BEDROOM

KITCHEN

DINING

ROOM

LIVING

ROOM

BATH

    

Smoke alarm  

for minimum protection

o

  

 Smoke alarm  
 for additional protection

    Smoke  alarm   

for minimum protection

o

    

Smoke alarm  

 for additional protection

Screw

Smoke Alarm

Ceiling

Install Bracket

Install hole