![Emec KMS AC MF Operating Manual Download Page 38](http://html1.mh-extra.com/html/emec/kms-ac-mf/kms-ac-mf_operating-manual_2399988038.webp)
38
18. “CONSTANT” WORKING MODE
CONSTANT mode.
Pump doses at a constant rate set in“SPH” (strokes for hour), “SPM” (strokes for
minute), “LPH” (litres per hour) parameters set during program session.
Which parameters must be set ?
SPH (strokes per hour), SPM (strokes per minute), LPH (litres per hour).
Choose “CONSTANT” working mode: “SPH” (strokes per hour), “SPM” (strokes per minute), “LPH” (litres per hour).
Use
“UP”
key to choose between these two modes. Use
“RIGHT”
key to change value. For next digit press again “RIGHT” key.
“LPH” value accuracy depends on cc/st value set into the Setup menu (SET [01] CC/ST).
LPH max value depends on the max frequency of the pump (refer to the pump’s label). If an higher value is set, the pump will show an alarm
message (ALARM STROKE).
Press
“E”
key to save data and “
ESC
” to exit to main menu. Otherwise press
“ESC”
to discard data and exit to main menu.
Note: last mode displayed before press the “E” key will be the active one.
mode [01]
CONSTANT
CONSTANT
100 spm
Key
E
CONSTANT
01 sph
Key
Key
CONSTANT
110.0 lph
Key
CONSTANT
11.00 lph
CONSTANT
1.100 lph
Key
Key