Electrostatic Sensitivity 

 

 

Observe electrostatic precautionary procedures.  Semiconductor laser transmitters and receivers provide 
highly reliable performance when operated in conformity with their intended design.  However, a 
semiconductor laser may be damaged by an electrostatic charge inadvertently imposed by careless 
handling. 
 
Static electricity can be conducted to the laser chip from the center pin of the RF input connector, and 
through the DC connector pins.  When unpacking and otherwise handling the transmitter, follow ESD 
precautionary procedures including use of grounded wrist straps, grounded workbench surfaces, and 
grounded floor mats. 
 
Exposure to electrostatic charge is greatly reduced after the transmitter or receiver has been installed in an 
operational circuit. 
 
Service 

 

Do not attempt to modify or service any part of the system other than in accordance with procedures 
outlined in this Operation Manual.  If the system does not meet its warranted specifications, or if a problem 
is encountered that requires service, return the apparently faulty plug-in or assembly to Emcore for 
evaluation in accordance with Emcore's warranty policy.   
 
When returning a plug-in or assembly for service, include the following information:  Owner, Model Number, 
Serial Number, Return Authorization Number (obtained in advance from Emcore's Customer Service 
Dept.), service required and/or description of the problem encountered.

 

Warranty 

 
Emcore warrants to the original purchaser all standard products sold by Emcore to be free of defects in 
material and workmanship for one (1) year from date of shipment from Emcore.  During the warranty 
period, Emcore's obligation, at our option, is limited to repair or replacement of any product that Emcore 
proves to be defective.  This warranty does not apply to any product that has been subject to alteration, 
abuse, improper installation or application, accident, electrical or environmental over-stress, negligence in 
use, storage, transportation, or handling. 

 

This warranty is the only warranty made by Emcore and is in lieu of all other warranties, expressed or 
implied, except as to title, and can be amended only by a written instrument signed by an officer of Emcore.  
Emcore sales agents or representatives are not authorized to make commitments on warranty returns. 
 
Limitations of Liabilities 
 
Emcore's liability on any claim of any kind, including negligence, for any loss or damage arising from, 
connected with, or resulting from the purchase order, contract, or quotation, or from the performance or 
breach thereof, or from the design, manufacture, sale, delivery, installation, inspection, operation or use of 
any equipment covered by or furnished under this contract, shall in no case exceed the purchase price of 
the device which gives rise to the claim. 

 

EXCEPT AS EXPRESSLY PROVIDED HEREIN, EMCORE MAKES NO WARRANTY OF ANY KIND, 
EXPRESSED OR IMPLIED, WITH RESPECT TO ANY GOODS, PARTS AND SERVICES PROVIDED IN 
CONNECTION WITH THIS AGREEMENT INCLUDING, BUT NOT LIMITED TO, THE IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.  EMCORE 
SHALL NOT BE LIABLE FOR ANY OTHER DAMAGE INCLUDING, BUT NOT LIMITED TO, INDIRECT, 
SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH 

Summary of Contents for 5021TR

Page 1: ...Copyright 2008 Emcore Corporation MAN 5021TR Rev B 333333333 System 5000 5021TR Wideband Transceiver Link Installation Manual...

Page 2: ...d Photovoltaics The company s integrated solutions philosophy embodies state of the art technology material science expertise and a shared vision of our customer s goals and objectives to be leaders i...

Page 3: ...est RF design features of Emcore s extensive families of products and combine them into a compact package compatible with the 10901G Power Supply The System5000 Wideband Microwave Transceiver family s...

Page 4: ...wer The LED illuminated indicates the laser is operating 10 above its set point 3 Laser Temp This LED illuminated indicates the laser is operating within 2 of its set point 4 Photodiode Optical Power...

Page 5: ...Interface Table 01 Pin Number Function 1 15 VDC 2 5 VDC 3 Not Used 4 Ground 5 Ground 6 Optical Current Monitor 7 Summary Alarm Common 8 Laser Current Monitor 9 Summary Alarm Operation Every step has b...

Page 6: ...locate the measure TG and RG values respectively The numbers added too 2 Optical Loss dB will give the overall system gain LED Indicator Tables Diagram TX Status LED Table 02 LED Alarm LED Good Trans...

Page 7: ...ptical Power alarm Specifications 5021TR RF Frequency 50 MHz 22 GHz Laser Power 8 to 10 dBmo RF Flatness 7 dB max pp RF Return loss 4 dB Carrier Noise ratio 115 dB Hz Carrier Intermod Ratio 55 dB Spur...

Page 8: ...310nm 9 dBm FC APC 5021TR B SA 1309 Txcr 7 GHz 50 Ohm SMA 1310nm 9 dBm SC APC 5021TR B FA 1309 Txcr 7 GHz 50 Ohm SMA 1310nm 9 dBm FC APC 5021TR C SA 1309 Txcr 13 GHz 50 Ohm SMA 1310nm 9 dBm SC APC 502...

Page 9: ...nd operation Failure to comply with the following general safety precautions and with specific precautions described elsewhere in this manual violates the safety standards of the design manufacture an...

Page 10: ...ser all standard products sold by Emcore to be free of defects in material and workmanship for one 1 year from date of shipment from Emcore During the warranty period Emcore s obligation at our option...

Page 11: ...not intended to imply that individual products or samples of products will achieve the same results These numbers are to be used as management and engineering tools and are not necessarily indicative...

Reviews: