NOTICE

DO NOT REMOVE an SP assembly while the "Unsafe to remove SP" LED shown below is lit.
 

 

Refer to 

Figure 3 on page 7

 while performing the procedure that follows.

Procedure

1. Disconnect the network and all other cables from the back of the SP assembly; label

the cables with the port numbers from which you removed them.

NOTICE

Do not remove any cables from the other SP assembly.

CAUTION

The SP assembly comes completely out of the enclosure. In addition to holding the
latches, be prepared to support the SP assembly to avoid dropping it.

2. Squeeze the orange levers on the latches on the sides of the SP assembly to release

the latches, and then pull the latches outward.

3. Pull out the latches until they are fully extended and the SP assembly is released from

the enclosure.

4. Use the latches to slide the SP assembly about half-way out of the enclosure.
5. Use both hands to support the SP assembly and pull it fully out of the enclosure.
6. Place the SP assembly on a clean, flat static-free work surface.

Figure 3  Removing an SP assembly

CL5231

2

1

7. Wait for all LED indicators on the removed SP to turn OFF before continuing.

This will occur in about 60 seconds.

Replacing an input/output module in a disk processor enclosure

Removing an SP assembly

     

7

Summary of Contents for VNXe

Page 1: ...n access to CPU board components You access an I O module from the rear of the enclosure NOTICE Always replace an I O module with one that is the exact same type Verify the type by reading the label o...

Page 2: ...that has accumulated on your body discharges through the circuits If the air in the work area is very dry running a humidifier in the work area will help decrease the risk of ESD damage Follow the pr...

Page 3: ...you must move around the room or touch other surfaces before installing a unit first place the unit back in the antistatic bag When you are ready again to install the unit repeat these procedures Har...

Page 4: ...when removing handling or storing replaceable units CAUTION Some replaceable units have the majority of their weight in the rear of the component Ensure that the back end of the replaceable unit is s...

Page 5: ...r filler panel to ensure proper air flow throughout the system Unpacking a part Procedure 1 Wear ESD gloves or attach an ESD wristband to your wrist and the enclosure in which you are installing the p...

Page 6: ...the storage processor with the part you are replacing SP A or SP B 4 Under Service Actions select Enter Service Mode then Execute service action 5 In the Service Confirmation dialog box click OK Putt...

Page 7: ...dropping it 2 Squeeze the orange levers on the latches on the sides of the SP assembly to release the latches and then pull the latches outward 3 Pull out the latches until they are fully extended and...

Page 8: ...back 1 4 inch 3 Lift the cover up Figure 4 Removing the SP top cover CL5233 1 3 2 Removing the I O module Refer to Figure 5 on page 9 while performing the procedure that follows Procedure 1 Lift the b...

Page 9: ...lignment pins NOTICE Do not attempt to seat the module into the CPU connector while you are holding the module at an angle Doing so will damage the connections The module should be flat before you att...

Page 10: ...tab secures the cover Figure 7 Replacing the SP top cover CL5234 3 1 2 Installing an SP assembly Refer to Figure 8 on page 11 while performing the procedure that follows Procedure 1 Pull out the latc...

Page 11: ...t Settings then Service System 2 Log in with your service password 3 In the System Components column select the storage processor currently in Service mode SP A or SP B 4 Under Service Actions select...

Page 12: ...aterial within 5 10 business days All instructions and material required to return your defective part were supplied with your good part shipment Procedure 1 Package the faulted part in the shipping b...

Page 13: ...ically disclaims implied warranties of merchantability or fitness for a particular purpose Use copying and distribution of any EMC software described in this publication requires an applicable softwar...

Reviews: