MAN-70007, Rev B, 02-20-2016
Page
29
of
31
PowerMax Innovation Inc.
1243 Reamwood Ave.,
Sunnyvale, CA 94089
Tel.: 408-541-0888; Fax. 408-541-1886
SECTION 7.0
MAINTENANCE AND SERVICING
7.1 PERIODIC MAINTENANCE
The only periodic maintenance required on the CW TWT amplifier system is insuring that the cooling
vents are not obstructed in such a manner that the air flow is restricted. Periodic cleaning of the vents
may be required depending on the degree of dust in the atmosphere.
7.2. SERVICING THE AMPLIFIER
Servicing of the amplifier by the operator is not recommended. Most of the internal circuitry requires
special and unique test instruments to trouble shoot, align and calibrate the circuits. Should servicing be
required, refer to Paragraph 7.3.
7.2.1 TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
COMMENTS
TFT display blank
No service voltages
Check line power.
Check service voltages,
+12VDC, -12Vdc, 5VDC
Connect AC line to
specified Prime power
source.
Refer to S/N tag on unit
Amp will not go to Operate
mode
High VSWR
Check RF output termination
connection.
When operating any RF
amplifier proper
termination must be
connected to the RF output
connector.
Power supply fault
Any of the high voltage
power supplies are
malfunction
Disconnect TWT leads and
Check high voltages on HV
terminal block when the
amplifier is powered ON
Danger High Voltages of
up to 12KV present
Thermal fault
Over-heating
Make sure airflow is adequate
and ambient temperature within
the limit.
THE EMC SHOP, 7401 GALILEE RD.
#160 ROSEVILLE, CA 95678
844.423.7435
WWW.THEEMCSHOP.COM
© THE EMC SHOP, LLC