Once you release the server from the inner rails, you must support the full weight of
the server.
4. Being prepared to support the full weight of the server, slowly pull the server forward
and remove it from the cabinet (
).
Figure 23 Releasing the inner rail locks and removing the server from the cabinet
CL5007
Removing the inner rails from the server
Use the procedure that follows to remove each inner rail from the server. Refer to
while performing the procedure.
Procedure
1. On the middle of the inner rail, push in and hold the metal latch, and push the rail
backward to release the connection studs from the small end of the rail notches.
2. When the connections studs are in the large end of the rail notches, release the metal
latch and pull the inner rail away from the server.
24
EMC SVR-I2U-R2312 Server Installation and Maintenance Guide