9
Step 5
Start DAE2s
1. Turn on the power for each DAE2 power supply.
2. If the cabinet power is not already on, be sure the other devices
in the system are correctly installed and ready for powerup, then
a. Plug the two 240-volt ac power cables into the power outlets in your
facility. We recommend connecting each power cable to a different
branch circuit. Both power cables must be connected to the
appropriate power supply. Connecting only one power source will
degrade the DAE2’s performance.
b. Turn on the circuit breakers on each of the cabinet’s side power
strips.
The green power lights on the front of the DAE2 chassis and on each disk
drive indicate that power is on; an amber chassis light indicates a fault.
If an amber light on the front of a DAE2 is lit, make sure the DAE2 is
correctly cabled, the enclosure addresses are correct, and the disks are
completely seated. Then refer to the fault code explanations in Chapter 3 of
the DAE2 Hardware Reference. If you cannot determine any reasons for
errors, contact your DAE2 service provider. (If you have an EMC service
contract, contact EMC Customer Service at USA (800) 782-4362,
Canada (800) 543-4782, or worldwide (508) 497-7901.)
EMC2166
Power LED
(Green)
Fault LED
(Amber)
Fault LED
(Amber)
Disk Activity
LED
(Green)
Summary of Contents for CLARiiON DAE2