EMC Services Zero Wire Manual Download Page 11

  

Report No    140805-2a 

    Page 11  of 18 

This report may not be reproduced in whole or in part without the permission  

of EMC Services Pty Ltd

 

 

 

Figure 3a.   

Radiated Emissions, 1000 MHz to 11000 MHz (Vertical)

  

 

 

 

Figure 3b.   

Radiated Emissions, 1000 MHz to 11000 MHz (Horizontal

Summary of Contents for Zero Wire

Page 1: ...9975 4555 Fax 61 2 9876 2796 Web www emc net au Report No 140805 2a Compliance Testing Report of the Zero Wire Alarm System to FCC Part 15 B Class B ANSI C63 4 2003 and FCC part 15 C Para 15 249 ANSI...

Page 2: ...EUT 3 3 Test Specifications 4 3 1 Standard Selected 4 3 2 Changes from the Selected Standard 4 3 3 Test Facility 4 3 4 Test Equipment 5 4 Test Summary 6 4 1 Emissions unintentional FCC Part 15 B Clas...

Page 3: ...t Description A security alarm system Model Zero Wire Module Number ZW 6400H Make UHS Supply 16 VAC 60 Hz through an AC Adapter 2 2 Accessory Equipment AC Adapter Make ZB Model Number ZB A090020A J Su...

Page 4: ...referred method of compliance with 47CFR Part 15 rules 3 2 Changes from the Selected Standard None 3 3 Test Facility All EMI tests reported within this document were performed by EMC Services Pty Ltd...

Page 5: ...specified uncertainty Description Model number Serial number Calibration due date Spectrum analyser HP 8591EM 3639A00972 5 12 2014 Spectrum analyser E4407B US40241411 13 11 2014 Antenna 30 MHz to 2 GH...

Page 6: ...missions Pass Radiated Emissions Pass 4 2 Radiated Emissions intentional to FCC part 15 C Para 15 249 Parameter Limit Measured Result Frequency 902 928 MHz 908 38 MHz Pass Field Strength 3 meters 94 d...

Page 7: ...ed Emissions The conducted emissions were measured using a LISN on the Active Neutral of the mains terminal The conducted emission plot and results are shown in figures 1a and 1b The minimum margin fo...

Page 8: ...e Frequency Peak QP Avg MHz dBuV dBuV dBuV 0 461 52 3 46 4 34 7 0 558 50 2 44 7 32 2 0 629 50 8 45 0 34 1 0 700 53 2 46 3 35 1 Figure 1b Mains Conducted Emissions 0 15 MHz to 30 MHz Neutral Conducted...

Page 9: ...37 0 203 999 49 7 40 5 499 990 44 9 42 5 624 986 46 8 44 3 Note Signals exceeding the limit level in the plot were ambients Figure 2a Radiated Emissions 30 MHz to 1000 MHz Horizontal FCC Part 15 Clas...

Page 10: ...176 39 6 34 8 142 989 40 1 35 9 148 142 40 6 34 8 155 957 42 1 33 6 Note Signals exceeding the limit level in the plot were ambients Figure 2b Radiated Emissions 30 MHz to 1000 MHz Vertical FCC Part...

Page 11: ...of 18 This report may not be reproduced in whole or in part without the permission of EMC Services Pty Ltd Figure 3a Radiated Emissions 1000 MHz to 11000 MHz Vertical Figure 3b Radiated Emissions 1000...

Page 12: ...Report No 140805 2a Page 12 of 18 This report may not be reproduced in whole or in part without the permission of EMC Services Pty Ltd 9 Test Facility...

Page 13: ...to operate the equipment In cases where the manual is provided only in a form other than on paper such as on a computer disk or over the internet the information required by this section may be inclu...

Page 14: ...st harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause h...