E-TRA3000
F-S-D-V-C_E-Manual
143/162
13 Appendix and Corrections
13.1 Appendix
13.1.1 Definition of the EFT Waveform
300ms
15ms
b) Burst Prüfsequenz
t
U
U
0,5
0,1
0,9
50ns+-30%
5ns+-30%
t
a) Spannungsform gemessen an 50 Ohm
Burst
Abhängig von der Prüfspannung
IEC 61000-4-4-Ed.2 specifies a verification of the waveform at 1000 Ohm
Burst-
Generator
50 Ohm Abschluss
50 Ohm Kabel
mit Teiler
UL
Memory oscilloscope
50 Ohm input
Checking the EFT tester. Checking procedure
1. The 50 Ohms terminating resistor, including the voltage divider, must be examined with a sinusoidal
voltage (CW) between 100 kHz and 200 MHz
2. The rise time must be between 3.5 and 6.5 ns.
3. The time to half value must be between 35 and 65 ns.
4. The source impedance of the tester is 50 Ohm, providing the coefficient of UL/Uout =2.
UL
= charging voltage
Uout
= output voltage into 50 Ohm
depends on spike frequency
Waveform measured at 50 Ohm
Burst test sequence
50 Ohm termination
50 Ohm cable
Summary of Contents for EXTTRA3000 E
Page 8: ...TRANSIENT3000 8 162...
Page 102: ...TRANSIENT3000 102 162...
Page 106: ...TRANSIENT3000 106 162...
Page 116: ...TRANSIENT 2000 116 162...
Page 118: ...TRANSIENT 2000 118 162...
Page 142: ...11BRemote Ports 142 162 All Generators of EMCP can be loaded and demonstrated...
Page 148: ...12BAppendix and Corrections 148 162 13 1 6 VARIATION Specification IEC 61000 4 11 Ed 2...
Page 150: ...12BAppendix and Corrections 150 162...
Page 156: ...14BIndex 156 162...
Page 158: ...14BIndex 158 162...
Page 160: ...14BIndex 160 162...
Page 162: ...14BIndex 162 162...