Installation Procedures

Installation

IND100078-34

Installation Procedure - TMB Versions

Procedure suitable for: Display (MMD/STD) and Panel Computer (MMC) Series X Generation (G1) product ranges.

19 inch model used as example in this procedure.

You need: 

- M4 Unbrako® Hex Key tool (not included with delivery).

- M7 Unbrako® Hex Key tool (not included with delivery) - Needed only for alternative procedure in Step 2,3.

- M17 Open End Wrench tool (not included with delivery) - Needed only for alternative procedure in Step 2,3.

- Fasteners (6 pcs M6) for mounting complete unit onto table or desktop location (not included with delivery).

- 1 pcs of HD TMB SX1-A1 Mounting Bracket Kit (for 12 and 15 inch)

- or 1 pcs of HD TMB SX1-B1 Mounting Bracket Kit (for 17 and 19 inch)

Boxed marked with GREY color below are considered alternative procedures. In most cases, these procedures can 

be ignored as suggested by factory.

Attention:

 A suitable pre-drilled location and knowledge of measurements for both main unit and 

brackets/tilting functionality should be prepared and checked prior to mounting. Please disconnect 

ALL cables before proceeding. Please review User Manual or visit www.hattelandtechnology.com 

for Technical Drawings regarding measurements for both main unit and Mounting Brackets.

▼ 1: Place the unit on a dry, fl at, clean, soft surface (i.e. table) 

with the glass front facing down as illustrated. Connector area 

should be facing downwards from you.

▼ 

2: By factory default the lower part of the bracket (Feet 

Base) are tightly fastened by the center Hex Socket Bolt and 

Locking Nut. Tilting can not be performed by hand. If you 

need to pre-confi gure the tilt angle of the fi nal assembled 

unit with brackets BEFORE you secure it into the installation

location, simply unscrew and loosen the Locking Nut (M17) 

fi rst and the Hex Socket Screw (M7) as indicated below. If 

there is no need to adjust the Feet Base (use recommended 

factory default position of 0 degree), skip to step 4 now.

Seen from 

above

Connector Area

1

2

▼ 

3: Once loosened a bit, pull out the Tilting Lock Pin, rotate it 90° (FIG1 / FIG2) and you are now able to tilt/rotate the Feet 

Base by hand (FIG3). Once the desired angle has been reached, rotate the Tilting Lock Pin 90°  and lock the angle into the 

nearest “click” the Locking Pin matches (FIG 1 / FIG2). Make sure both Feet Base are tilted/rotated to EXACTLY the same

angle! Secure both Hex Socket Bolts and Locking Bolt (FIG4) so they cannot move by themselves when proceeding to next 

step.  Use Torque Force 25Nm.

FIG1

FIG2

Locked      Unlocked

FIG3

FIG4

Summary of Contents for HATTELAND TECHNOLOGY HD TMB-SX1-A1

Page 1: ...ktop Ceiling 12 15 17 19 Typenumber Illustration Fits unit model Footprint indicates holes to drill at installation location HD TMB SX1 A1 HD 12T21 MMD xxx Fxxx HD 12T21 STD xxx Fxxx HD 12T21 MMC xxx xxxx HD 15T21 MMD xxx Fxxx HD 15T21 STD xxx Fxxx HD 15T21 MMC xxx xxxx HD TMB SX1 B1 HD 17T21 MMD xxx Fxxx HD 17T21 STD xxx Fxxx HD 17T21 MxC xxx xxxx HD 19T21 MMD xxx Fxxx HD 19T21 STD xxx Fxxx HD 19...

Page 2: ...kewise to get a correct footprint placement of the brackets both brackets feature a slight angled design on the oval circled cut shaped block to compensate for this FIG2 making LEFT and RIGHT bracket slightly different and naturally has to be correctly mounted Please ensure that LEFT and RIGHT brackets are as indicated in FIG4 and not as shown in FIG3 below FIG 1 Red Line straight up Green Line in...

Page 3: ...cables before proceeding Please review User Manual or visit www hattelandtechnology com for Technical Drawings regarding measurements for both main unit and Mounting Brackets 1 Place the unit on a dry flat clean soft surface i e table with the glass front facing down as illustrated Connector area should be facing downwards from you 2 By factory default the lower part of the bracket Feet Base are ti...

Page 4: ...EFT RIGHT 6 Ensure that both Key Hole Plugs slide into the Key Holes and goes to the upper position factory recommended FIG1 and FIG2 If they appear too tight you may loose the Key Hole Plug screw a few turns and re try see previous step 4 You can also alternatively use the lower position of Key Hole to add extra height under unit to allow cables and or additional installed connectors to fit in tig...

Page 5: ...d tilting position has been achieved you need to verify that the Tilting Lock Pin are in locking position and the unit is firmly attached and does not appear loose FIG2 FIG2 Re check Lock Pins FIG1 Alternative Mounting Depending on installation needs you may mount the complete unit in ceiling in two different ways Normal Position User Controls will be upside down cables go straight up You may config...

Reviews: