background image

www.sureheat.com

11

200085-01A

INSTALLATION

CONNECTING TO GAS SUPPLY

  CAUTION:  For  natural  gas, 

check  your  gas  line  pressure 

before connecting heater to gas 

line. Gas line pressure must be 

no  greater  than  10.5"  of  w.c.  If 

gas line pressure is higher, heater 

regulator damage could occur.

 CAUTION: Avoid damage to 

regulator.  Hold  gas  regulator 

with  wrench  when  connecting 

into gas piping and/or fittings.

  CAUTION:  Use  pipe  joint 

sealant that is resistant to gas 

(Propane/LP or Natural Gas).

Before installing heater, make sure you have 

the items listed below:
•  external regulator for propane/LP unit only 

(supplied by installer)

•  piping (check local codes)
•  sealant (resistant to natural gas and pro-

pane/LP gas)

•  equipment shutoff valve*
•  test gauge connection*
•  sediment trap
•  tee joint 
•  pipe wrench
•  flexible gas hose (check local codes) 
* A  CSA  design-certified  equipment  shutoff 

valve with 1/8" NPT tap is an acceptable al-

ternative to test gauge connection. Purchase 

the optional CSA design certified equipment 

shutoff  valve  from  your  dealer  (see 

Acces-

sories

, page 24).

Typical Inlet Pipe Diameters

Use 1/2" black iron pipe or greater. Installa-

tion must include an equipment shutoff valve, 

union, and plugged 1/8" NPT tap. Locate NPT 

tap within reach for test gauge hook up. NPT 

tap must be upstream from heater (see Figure 

10, page 12).

IMPORTANT: Install an equipment shutoff 

valve in an accessible location. The equip-

ment shutoff valve is for turning on or shutting 

off the gas to the appliance.

  WARNING: A  qualified  ser-

vice  technician  must  connect 

heater to gas supply. Follow all 

local codes.

  WARNING:  This  appliance 

requires  a  3/8"  NPT  (National 

Pipe Thread) inlet connection to 

the pressure regulator.

 WARNING: For natural gas, 

Never connect heater to private 

(non-utility) gas wells. This gas 

is commonly known as wellhead 

gas.

  CAUTION:  For  propane/LP 

gas, never connect heater direct-

ly to the gas supply. This heater 

requires  an  external  regulator 

(not supplied). Install the external 

regulator between the heater and 

propane/LP gas supply. Gas sup-

plier provides external regulator 

for  natural  gas.  The  installer 

provides the external regulator 

for propane/LP gas.

  WARNING:  Do  not  over-

tighten gas connections.

 CAUTION: Use only new, 

black  iron  or  steel  pipe.  Inter-

nally tinned copper tubing may 

be used in certain areas. Check 

your  local  codes.  Use  pipe  of 

1/2" diameter or greater to allow 

proper gas volume to heater. If 

pipe is too small, undue loss of 

pressure will occur.

Summary of Contents for VFS25NL

Page 1: ...al switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire de...

Page 2: ...combustionandventilationairmustbeprovided Refer to Air For Combustion and Ventilation section on page 7 of this manual WARNING Improper installation adjustment al teration service or maintenance can c...

Page 3: ...e of alcohol and those at high altitudes NATURALAND PROPANE LP GAS Natural and Propane LP gas are odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the odo...

Page 4: ...vations of 4 500 feet could cause pilot outage 11 To prevent performance problems do not use propane LP fuel tank of less than 100 lbs capacity 12 Do not use this heater as a wood burning heater Use o...

Page 5: ...om tem perature 2 GAS OPTIONS AVAILABLE Your heater is equipped to operate on either Propane LP or Natural gas The heater is shipped from the factory ready for connect ing to Propane LP The heater can...

Page 6: ...air and circulation air 2 If high humidity is experienced a dehu midifier may be used to help lower the water vapor content of the air 3 Do not use an unvented room heater as the primary heat source...

Page 7: ...appli ances WARNING This heater shall not be installed in a room or space unless the required vol ume of indoor combustion air is provided by the method de scribed in the National Fuel Gas Code ANSI...

Page 8: ...ir Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic INSTALLATION NOTICE This heater is intended for use as supplemental heat Use this heater along with your primary heating system Do...

Page 9: ...most point of heater to any combustible side wall should not be less than 12 B Clearances from the heater to the ceiling should not be less than 48 GAS SELECTION This appliance is factory preset for p...

Page 10: ...ion device and reinstall screws 4 Remove hex plug with wrench provided from natural gas inlet of regulator and discard see Figure 7 Install gas line into NG inlet of regulator Use thread sealant to as...

Page 11: ...nstalla tion must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 10 page 12 IMPORTA...

Page 12: ...ent down protects it from freezing rain or sleet Install sediment trap in supply line as shown in Figure 10 Place sediment trap where it is within reach for cleaning Place sediment trap where trapped...

Page 13: ...ints Ifbubblesform there is a leak Correct all leaks at once PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect heater with its appliance main gas valv...

Page 14: ...t heater see Lighting Instructions on page 16 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas Ap pliance page 17 AAA Battery Positive UP BATTERY INSTRUCTIONS CAUTION Do...

Page 15: ...ide of log 1 with one end resting on log 3 IMPORTANT Make sure logs do not cover any burner ports It is very important to install the logs exactly as instructed Do not modify logs Use only logs suppli...

Page 16: ...th the screen in place Make sure screen is installed before running heater NOTICE Duringinitialoperationof new heater burning logs will give offapaper burningsmell Orange flame will also be present Op...

Page 17: ...t After 30 seconds release control knob 5 Make sure the heater screen is in place before operating heater TO TURN OFF GAS TO APPLIANCE MANUAL LIGHTING PROCEDURE Note If pilot does not stay lit refer t...

Page 18: ...Off Gas to Ap pliance page 17 see Troubleshooting pages 21 through 23 WARNING If yellow tipping occurs the pilot should be cleaned Notice Do not mistake orange flames with yellow tipping Dirt or other...

Page 19: ...r Inlet Holes BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE We recommend that you clean the unit ev ery 2 500 hours of operation or every three months We also recommend that you keep the burner tube...

Page 20: ...th the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 23 Pilot Inlet Air Hole Pilot Air Inlet Hole Natural Gas Bur...

Page 21: ...trode is broken 2 Ignitor electrode is not con nected to ignitor cable 3 Ignitor cable is pinched or wet 4 Broken ignitor cable 5 Bad piezo ignitor 6 Low battery 1 Replace electrode 2 Replace ignitor...

Page 22: ...is lit 1 Burner orifice is clogged 2 Burner orifice diameter is too small 3 Inlet gas pressure is too low 1 Clean burner orifice see Care and Maintenance page 19 or replace burner orifice 2 Replace b...

Page 23: ...jacent walls or furniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or simi...

Page 24: ...oning Type of gas used Propane LP or Natural gas NG Purchase date Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Call Customer Service toll free at 1 800...

Page 25: ...heat propane LP gas supply might be low propane LP units only You may feel your gas pressure is too low If so contact your local gas supplier TECHNICAL SERVICE You may have further questions about ins...

Page 26: ...www sureheat com 200085 01A 26 PARTS MODEL VFS25NL 5 7 8 10 11 12 6 9 1 2 3 4 18 15 16 14 17 13...

Page 27: ...Door 1 5 NDD0308 400 ODS Pilot 1 6 ML073 04 Igniter Cable 1 7 YDF06 QD250T Fuel Selection Device Assembly 1 8 MDL304B Selector Knob 1 9 PIMSC1 01 Piezo Ignitor 1 10 RV83FI 4 9 Regulator 1 11 PF120820...

Page 28: ...age resulting from any of the following Negligent use or misuse of the product including exposing the product to chemicals or cleaning products not approved by SHM International Corp Corrosion rust or...

Page 29: ...el ctrico no use nin g n tel fono en el edificio Llame inmediatamente a su proveedor de gas des de el tel fono de alg n vecino Siga las instruccio nes del proveedor de gas Si no puede localizar al pr...

Page 30: ...s necesarias para garantizar que hay suficiente aire para la combusti n y ventilaci n Consulte la secci n Aire para combusti n y ventilaci n en la p gina 36 de este manual ADVERTENCIA La instalaci n a...

Page 31: ...tador no est funcio nando correctamente Respire aire fresco inmediatamente Haga que le den servicio al calentador El mon xido de carbono afecta m s algunas personas que a otras Las m s afectadas son m...

Page 32: ...apores inflamables en condiciones con mucho polvo 7 Apague el calentador antes de usar puli dores de muebles ceras limpiadores de alfombras o productos parecidos Si se calientan los vapores que se des...

Page 33: ...las autoridades que tienen jurisdicci n 16 Este calentador de le os est dise ado para no producir humo Si pareciera que los le os producen humo apague el ca lentador y llame a un t cnico calificado N...

Page 34: ...RMAS LOCALES Instale y use el calentador con cuidado Siga todaslasnormaslocales Afalta de normasloca les utilice la ltima edici n del C digo Nacional de Gas Combustible ANSI Z223 1 NFPA 54 Disponible...

Page 35: ...n adecuadas del aire 2 Si hay humedad elevada se puede utilizar un deshumidificador para ayudar a reducir el contenido de vapor de agua del aire 3 No utilice un calentador de habitaci n sin ventilaci...

Page 36: ...su funcionamiento Usted debe proporcionar la cantidad adecuada de aire fresco para estos aparatos Esto asegura que la ventilaci n de los aparatos que queman combustible sea la adecuada ADVERTENCIA Est...

Page 37: ...arto adyacente opci n 3 Rejillas de ventilaci n hacia un cuarto adyacente opci n 2 Rejillas de ventilaci n hacia un cuarto adyacente opci n 1 30 48 cm 12 30 48 cm 12 Figura 4 Aire del interior de la c...

Page 38: ...or De lo contrario llame al distribuidor donde compr el calen tador para el calentador de tipo adecuado INSTALACI N Figura 6 Distancia m nima a la pared y al techo ESPACIO LIBRE PARA MATERIALES COMBUS...

Page 39: ...uir la cubierta de acceso antes de completar la instalaci n y funcionamiento de este dispositivo Para cambiar de gas propano a gas natural 1 Retire los 2 tornillos de la placa de cubier ta del selecto...

Page 40: ...gura 8 Colo que el tap n hexagonal en la entrada NG del regulador Instale la tuber a de gas en la entrada del regulador de gas LP Utilice sellador de roscado para evitar fugas Back of Stove Perilla de...

Page 41: ...or consulte la secci n Accesorios p gina 56 PRECAUCI N Utilice nica mente tuber a nueva de hierro negro o de acero En algunas reassepuedeutilizartuber ade cobre con interior galvanizado Consulte los c...

Page 42: ...esde el calentador consulte la figura 10 IMPORTANTE instale una v lvula de cierre del equipo en un lugar que sea accesible La v lvula de cierre del equipo es para abrir o cerrar el suministro de gas a...

Page 43: ...usando aire comprimido 4 Revise todas las uniones del sistema de tuber a de suministro de gas Aplique en todas las uniones alg n l quido de detec ci n de fugas que no sea corrosivo La formaci n de bu...

Page 44: ...alentador consulte Instruc ciones de Encendido en la p gina 46 Revise el resto de las uniones internas para ver si hay fugas 7 Apague el calentador consulte C mo cerrar el suministro de gas al aparato...

Page 45: ...o Este n mero lo ayudar a identificar los le os al instalarlos No agregue ceniza decorativa sobre los le os ni el quemador 1 Retire el material de embalaje del le os El n mero de le o est marcado en l...

Page 46: ...den producir un incendio o una explosi n D No use este aparato si alguna de sus partes estuvo sumergida en agua Llame inmediatamente a un t cnico ca pacitado de servicio para que inspec cione el apara...

Page 47: ...e servicio calificado o proveedor de gas para las reparaciones Encienda el piloto con un f sforo hasta que se realicen las reparaciones Para encender el piloto con un f sforo Con sulte el Procedimient...

Page 48: ...ermostato utilizado en este calentador detecta la temperatura ambiente A veces el ambiente puede superar la tempe ratura establecida Si es as el quemador se apagar El quemador volver a encenderse cuan...

Page 49: ...ri dicamente que estos orificios no est n bloqueados y limpie si es necesario Si los orificios se bloquean producir n holl n En la figura 21 se muestra el patr n correcto de la flama del quemador En l...

Page 50: ...cipa les del sujetador del inyector 6 En caso de que una obstrucci n grande o polvo haya sido empujada hacia el interior del quemador repita los pasos 3 y 4 CUIDADO Y MANTENIMIENTO ADVERTENCIA Apague...

Page 51: ...las instrucciones de colocaci n Remplace el le o s si est roto o astillado roturas de 1 7 cm o m s grandes SOLUCI N DE PROBLEMAS ADVERTENCIA Si percibe olor a gas Cierre el suministro de gas No inten...

Page 52: ...ci n o interrupci n gas reciente 4 El piloto ODS est tapado 5 La presi n de gas es in adecuada o el regulador de entrada de gas est da ado 6 La perilla de control no est en la posici n PILOTO 7 Se ago...

Page 53: ...n quese con la com pa a local de gas natural o de gas propano LP B Limpie el piloto ODS consulte Cuidado y man tenimiento en la p gina 50 o remplace el ensamble del piloto ODS 6 Remplace el termopar 7...

Page 54: ...ntrol a la posici n HI Alto cuando el quemador estaba fr o 2 Hay aire en la tuber a de gas 3 Los pasajes de aire del ca lentador est n bloqueados 4 El orificio del quemador est sucio o parcialmente ob...

Page 55: ...te el tanque de suministro gas propano LP nicamente El calentador se apaga mientras se est usando el ODS funciona 1 No hay suficiente aire fresco 2 Hay poca presi n en la tuber a 3 El piloto ODS est p...

Page 56: ...proporcionarle estos acce sorios comun quese SHM International Corp al 1 800 229 5647 para obtener informaci n V LVULADE INTERRUPCI N DE EQUIPOS RMH 120 00088 Para todos los modelos V lvula de interru...

Page 57: ...cado El suministro de gas propano LP puede ser bajo Posiblemente piense que la presi n del gas es muy baja Si es as comun quese con el proveedor local de gas SERVICIO T CNICO Es posible que tenga preg...

Page 58: ...www sureheat com 200085 01A 58 PIEZAS MODELO VFS25NL 5 7 8 10 11 12 6 9 1 2 3 4 18 15 16 14 17 13...

Page 59: ...DS Piloto 1 6 ML073 04 Cable de arrancador 1 7 YDF06 QD250T Ensamble dispositivo de selecci n de combustible 1 8 MDL304B Selecci n de combustible perilla 1 9 PIMSC1 01 Encendedor 1 10 RV83FI 4 9 Regul...

Page 60: ...tancias qu micas o productos de limpieza no aprobados por SHM International Corp Corrosi n oxidaci n o des coloraci n de cualquier tipo Uso o instalaci n contrarios a las instrucciones especificadas y...

Reviews: