ES5 Series - Manintenance and Service

Strainers:

ES5M, ES5M18 & ES5MT

: Strainer is in bottom of pump. Remove wire ring, then strainer 

wash and replace.

ES5CTS, ES5CTS18, ES5PBS & ES5PBS18

: Strainer is located in front center of bottom. 

Slip strainer off  Tube, wash and replace.

ES5PB, ES5PB18 ES5CT & ES5CT18:

 To wash strainer located in hose:

1.  Remove hose.
2.  Remove quick connect fi tting.
3.  Reverse hose (connect steamer end to supply valve). Drain into sink or bucket.
4.  Run water through hose to clean.
5.  Return to original connections.

There is a strainer in inlet of solenoid valve that normally does not require cleaning but under 
 extreme conditions may have to be removed and cleaned.
 

 

 

__________________________________________

Service

 

 

DANGER: Before attempting service, unplug power cord.

We recommend any service be done by qualifi ed service personnel. Refer to separate Parts List for 
parts identifi cation and assembly guide.
1.  All electrical components are contained in enclosure behind switch panel. For access, remove 

sloping front and switch panel.

2.  ES5M, ES5M18 & ES5MT pump is easily removed for service or replacement. Disconnect 

water line (under steamer) from pump, open electric enclosure, disconnect linkage and remove 
two screws holding pump.

3.  To remove ES5CTS, ES5CTS18, ES5PBS & ES5PBS18 pump:

A. 

Disconnect electric wires from terminals.

B. 

Disconnect discharge hose from pump.

C. 

Remove two screws through bottom of steamer holding pump bracket.

D. 

Lift pump out.

4.  To adjust lid, loosen screws in lower hinge. With lid closed, tighten screws.
5.  Thermostat is set to control temperature from 350° to 375°, and we suggest replacement if off  

calibration. Thermostat may be removed by:

A. 

Removing electric enclosure covers and switch panel.

B. 

Removing wires from thermostat terminals.

C. 

Removing two screws holding thermostat.

D. 

Pull capillary straight out to remove bulb.

 

 

CAUTION: Capillary tube is critical and care should be taken not to “kink”.

6.  f water nozzle should clog with lime, remove by lifting up then clean small holes with paper clip 

or similar tool. Lime inside tube is removed by fl exing tube, then shaking or washing out lime.

7.  The water inlet is cleaned by removing plug at bottom and pushing lime out with wire or rod.
8.  The main timer controls the cooking time and the shot timer delivers a measured amount of 

water to produce steam every 20 seconds. If defective, replace (attempted service may aff ect 
timing).

 

 

DANGER: Read and understand this bulletin thoroughly before starting any 

troubleshooting. An inadvertent service error could result in severe personal injury or death. 
Only a trained experienced service technician should attempt any repair procedure.

Qualifi ed service agencies are available at most locations—Refer to EmberGlo listing of Authorized 
Service Agencies included in Standard Equipment Catalog.
Important: Defective wiring or loose connections can simulate the defects outlined below. Check 
 associated wiring before replacing a component.
 

 

 

__________________________________________

Service

Maintenance -
Daily Continued

Summary of Contents for ES5 Series

Page 1: ...op Open Half Pan Counter Top Steamer C O MPAN Y R E G ISTER E D EmberGlo A Div of Midco International Inc 4140 West Victoria Street Chicago Illinois 60646 toll free866 705 0514 tel 773 604 8700 fax 86...

Page 2: ...4 2006e for steamers to have ventilation 5 Lid Angle Adjustment To adjust the angle of the lid to 60 or 90 1 With the lid closed loosen and remove slotted screw Set aside 2 Remove lid stop by sliding...

Page 3: ...OFF position Timer Operating Instructions with ES5CT ES5CT18 ES5CTS ES5CTS18 timer steamers See Figure 2 for locations of buttons and switches 1 ES5CTS ES5CTS18 Fill the water reservoir at the beginni...

Page 4: ...T BLK PILOT ON OFF R PUSH BUTTON NC NO COM SOLENOID VALVE S BLK WHT BLK FRONT PANEL CHASSIS SOLENOID VALVE THERMOSTAT THERMAL FUSE HEATING ELEMENT PUSH BUTTON PILOT ON OFF HEATING ELEMENT LINE CORD ES...

Page 5: ...T 1 2 3 6 7 CYCLE TIMER INITIATE NEUT 3 7 6 NC SHOT TIMER NO COM AIROTRONICS TIMERS OFF 5 4 ON 1 8 9 5 HOT 2 AC LOAD 1 INPUT 2 3 7 6 5 4 CYCLE TIMER INITIATE 3 INPUT 5 4 NO SHOT TIMER NC COM ACP TIMER...

Page 6: ...utes 3 ES5M ES5M18 ES5MT Push the manual lever two to three times ES5PB ES5PB18 ES5PBS ES5PBS18 Push the button long enough to spray water on the generator surface 4 Watch the water turn into steam Al...

Page 7: ...through bottom of steamer holding pump bracket D Lift pump out 4 To adjust lid loosen screws in lower hinge With lid closed tighten screws 5 Thermostat is set to control temperature from 350 to 375 an...

Page 8: ...ee Service section Rebuild or replace as required D Models ES5PB ES5PB18 ES5CT ES5CT18 1 Con rm Water Shut O Valve is on and Water Hose Assembly is properly hooked up Refer to 3 from the Installation...

Page 9: ...n Poached 3 min Scrambled dz 5 min Meat Bratwurst 8 min 16 min Breakfast sausage 8 min 14 min Chicken breast lg 15 min 25 to 30 min Chicken breast precooked 5 min 15 min Deli meats 2 to 3 min Hamburge...

Page 10: ...nor does it apply to limed steam generators nor does it apply to any consequential damages Most geographical areas require the use of distilled or demineralized water Tap water is permissible only wi...

Page 11: ...Call factory for information 866 705 0514 Fill out form and fax to 866 580 8700 or copy and mail to EmberGlo Div of Midco International Inc 4140 West Victoria Street Chicago Illinois 60646 Date of Pu...

Page 12: ...is 60646 PLACE STAMP HERE FOLD LINE FOLD LINE EmberGlo A Division of Midco International 4140 West Victoria Street Chicago Illinois 60646 toll free 866 705 0515 tel 773 604 8700 fax 866 580 8700 web w...

Reviews: