EmberGlo
A Division of Midco International Inc
8449 96
7
ES5 Series - Manintenance and Service
Strainers:
ES5M, ES5M18 & ES5MT
: Strainer is in bottom of pump. Remove wire ring, then strainer
wash and replace.
ES5CTS, ES5CTS18, ES5PBS & ES5PBS18
: Strainer is located in front center of bottom.
Slip strainer off Tube, wash and replace.
ES5PB, ES5PB18 ES5CT & ES5CT18:
To wash strainer located in hose:
1. Remove hose.
2. Remove quick connect fi tting.
3. Reverse hose (connect steamer end to supply valve). Drain into sink or bucket.
4. Run water through hose to clean.
5. Return to original connections.
There is a strainer in inlet of solenoid valve that normally does not require cleaning but under
extreme conditions may have to be removed and cleaned.
__________________________________________
Service
DANGER: Before attempting service, unplug power cord.
We recommend any service be done by qualifi ed service personnel. Refer to separate Parts List for
parts identifi cation and assembly guide.
1. All electrical components are contained in enclosure behind switch panel. For access, remove
sloping front and switch panel.
2. ES5M, ES5M18 & ES5MT pump is easily removed for service or replacement. Disconnect
water line (under steamer) from pump, open electric enclosure, disconnect linkage and remove
two screws holding pump.
3. To remove ES5CTS, ES5CTS18, ES5PBS & ES5PBS18 pump:
A.
Disconnect electric wires from terminals.
B.
Disconnect discharge hose from pump.
C.
Remove two screws through bottom of steamer holding pump bracket.
D.
Lift pump out.
4. To adjust lid, loosen screws in lower hinge. With lid closed, tighten screws.
5. Thermostat is set to control temperature from 350° to 375°, and we suggest replacement if off
calibration. Thermostat may be removed by:
A.
Removing electric enclosure covers and switch panel.
B.
Removing wires from thermostat terminals.
C.
Removing two screws holding thermostat.
D.
Pull capillary straight out to remove bulb.
CAUTION: Capillary tube is critical and care should be taken not to “kink”.
6. f water nozzle should clog with lime, remove by lifting up then clean small holes with paper clip
or similar tool. Lime inside tube is removed by fl exing tube, then shaking or washing out lime.
7. The water inlet is cleaned by removing plug at bottom and pushing lime out with wire or rod.
8. The main timer controls the cooking time and the shot timer delivers a measured amount of
water to produce steam every 20 seconds. If defective, replace (attempted service may aff ect
timing).
DANGER: Read and understand this bulletin thoroughly before starting any
troubleshooting. An inadvertent service error could result in severe personal injury or death.
Only a trained experienced service technician should attempt any repair procedure.
Qualifi ed service agencies are available at most locations—Refer to EmberGlo listing of Authorized
Service Agencies included in Standard Equipment Catalog.
Important: Defective wiring or loose connections can simulate the defects outlined below. Check
associated wiring before replacing a component.
__________________________________________
Service
Maintenance -
Daily Continued