AIR DRYER INSTRUCTION MANUAL

 

Excessive air flow 

Check flow rate and select 

dryer newly 

Freezing of moisture in 

evaporator because of 

refrigeration system 

improperly functioning 

Adjust hot gas bypass valve 

clockwise 

Pipeline diameter too small 

Pipeline too long 

Pipeline elbows too many 

Install new pipeline  

Inlet/Outlet valve not open 

completely 

Open inlet/outlet valve 

completely 

High pressure drop 

across dryer 

Pipeline leak 

Leak test 

Low inlet air pressure 

High ambient air temperature 

High inlet air temperature 

High air flow 

Check Dryer Selection 

Air bypass valve open

 

Close air bypass valve

 

Refrigeration system 

not functioning 

properly 

drain troubleshooting 
a.

 

Manual valve not open 

b.

 

Drain jam or damage 

Drain line higher than drain 
condensate outlet 

Open manual valve 
Clean and replace drain 
Install condensate line Newly 

Fuse burn off 

Replace fuse 

Condense pressure too high 
bring on high pressure switch 
open 
Ambient temperature too high
Inlet temperature too high 
Air flow too high 

Adjust working status or select 
dryer newly 

Evaporate pressure too low 
bring on low pressure switch 
open 
Ambient temperature too low 
Thermostatic expansion valve 
opening degree too small or 
jam 
Refrigerant leak 

Adjust hot gas bypass valve 
regulator clockwise 
Adjust or replace thermostatic 
expansion valve 
Replace dryer/filter 
Check leak 

Electric component damage 

Replace damaged component 

Stop at running 

process 

Compressor damage 

Replace compressor 

 

Summary of Contents for EDRYHT0028

Page 1: ......

Page 2: ...AIR DRYER INSTRUCTION MANUAL 0 Contents GENERAL SAFETY INFORMATION 1 READ PRIOR TO STARTING THIS EQUIPMENT 1 DESCRIPTION 2 INSTALLATION 3 OPERATION 5 MAINTENANCE 6 FLOW SCHEMATIC 7 TROUBLESHOOTING 8...

Page 3: ...READ PRIOR TO STARTING THIS EQUIPMENT 1 This equipment has been thoroughly checked packed and inspected before leaving out plant 2 This equipment is shipped to accommodate a forklift truck When insta...

Page 4: ...duces product contamination and increases productivity Working flow Compressed air saturated with water vapor enters the dryer and is pre cooled by the outgoing refrigerated air in an air to air heat...

Page 5: ...refrigerant reduces to a low pressure low temperature mixture of liquid and vapor after passing through the thermostatic expansion valve and evaporator as it takes heat from the compressed air The lo...

Page 6: ...efore the dryer air inlet valve and after the dryer air outlet valve This bypass valve always be install to permit the continued use of the plant compressed air system during any dryer maintenance or...

Page 7: ...nes for a few minutes to remove welding slag Start up 1 Check the low refrigeration pressure gauge it should indicate higher than 0 25MPa 2 If the voltage is at normal range open electric control box...

Page 8: ...ter 10 minutes Shutdown Close the dryer air inlet valve and press the control button to shut then disconnect the power and close the water supply valve MAINTENANCE Air cooled condenser Ambient air sho...

Page 9: ...l bolt and detach the shell take filter core out and clean it with brush and water d Reassemble the core and the shell Then open the manual valve ahead of drain Electric apparatus Check parts in the e...

Page 10: ...itch improperly set Set properly Air cooled models Dirty clogged condenser fins obstructed air flow across condenser Clean condenser and check for free air flow Too much refrigerant Let out excessive...

Page 11: ...functioning properly drain troubleshooting a Manual valve not open b Drain jam or damage Drain line higher than drain condensate outlet Open manual valve Clean and replace drain Install condensate li...

Reviews: