Emax 815002013978 Operating Instructions Manual Download Page 8

8

HULK Power

used (C, fig 5) it must be attached to the metal screw 

of the receptacle.

The use of an adaptor plug is illegal 

in some areas, including Canada. 

Check your local codes. If you have any doubts 

or if the supplied plug does not correspond to 

your electrical outlet, consult a qualified 

electrician before proceeding.

Connect to power source

Consult a qualified electrician for proper installation 

of receptacle at the source of power. This tool must 

be grounded while in use to protect the operator from 

electrical shock. If you are not sure if your outlet is 

properly grounded, have it checked by a qualified 

electrician. Make sure the tool is turned OFF when 

connecting the power cord to a properly grounded 

120 Volts, 60 Hz, single phase, 15 amp power 

source.

Getting Started 

Unpack your compressor.

Before operating your tool, check the contents of the 

box to make sure you have everything you will need. 

Items included in the box:

 

Air Compressor

 

Air Filter

 

Owner’s Manual

Save packaging in case you need to 

return the compressor for servicing or 

 

 

      repair.

Assembly

Before performing any assembly or 

maintenance, make sure compressor 

is turned off and unplugged from the power 

supply.

Place compressor on level ground. It is designed to 

function properly at an incline of no greater than 15 

degrees.

Installing the air filter 

The air filter should be installed into the top left side 

of motor head (looking from the front to the back of 

the air compressor like in position 7, fig 2, above). 

1. 

Thread the air filter into motor head port located 

under the plastic shroud.

2. 

Carefully screw the air filter (fig 2.7) into the 

cylinder head by turning the air filter clockwise, 

hand tight.

DO NOT over-tighten the air filter.

3. 

Be sure the short length of flexible hose is 

inserted into the hole in the air filter housing. This 

increases the noise-reduction capabilities of your 

compressor.

Operation 

Before operating your new air compressor: 

 

Inspect for damage before using the air 

compressor, make sure the air tank is not 

damaged, inspect all parts for damage, and 

NOTICE

NOTICE

NOTICE

NOTICE

check that all pipes and hoses are firmly 

connected.

 

Do not use the air compressor if any damage is 

found. If damaged, have an authorized service 

center inspect and test the air compressor to 

ensure that is working properly.

 

Pull the ring on the safety valve before each use 

to make sure the valve is functional. 

 

Depending on the CFM draw of the tools being 

operated, your new air compressor can be used 

for operating paint sprayers, air tools, grease 

guns, airbrushes, caulking guns, abrasive 

blasters, tire & plastic toy inflation, spraying 

weed killer and insecticides, etc. Proper 

adjustment of the air pressure regulator is 

necessary for all of these operations. Refer to 

the air pressure specifications provided with the 

tool you are using.

General Overview

Installation and Location

Locate the compressor in a clean, dry and well 

ventilated area. The compressor should be located 

12 to 18 inches (30 to 45 cm) from walls or any 

other obstruction which would interfere with airflow. 

Compressor should be located in a temperature-

controlled area between 32° and 95° fahrenheit  

(0 ° and 35 °C). Place the compressor on a firm, 

level surface. The compressor is designed with heat 

dissipation fins which allow for proper cooling. Keep 

the fins (and all other parts which collect dust or dirt) 

clean. A clean compressor runs cooler and provides 

longer service. Do not place rags, containers or other  

material on top of the compressor.

Connecting to Power Source

This air compressor is designed to operate on a 

properly grounded 120 volt, 60 Hz, single phase, 

alternating current (AC) power source with a fused 

20 amp time-delayed fuse or circuit breaker. It is 

recommended that a qualified electrician verify the 

ACTUAL VOLTAGE at the receptacle into which the 

unit will be plugged and confirm that the receptacle is 

properly fused and grounded. The use of the proper 

circuit size can eliminate nuisance circuit breaker 

tripping while operating your air compressor.

Extension Cords

 

For optimum air compressor performance an 

extension cord should not be used unless 

absolutely necessary. 

 

If you must choose between an electrical 

extension cord and a longer air hose, choose 

the latter. It is far better for the life of the 

compressor. If necessary, care must be taken in 

selecting an extension cord appropriate for use 

with your specific air compressor. 

 

Use a heavy-gauge extension, since very thin 

or very long cord may cause voltage drop 

and result in loss of power in the compressor 

and overheating. Select a properly grounded 

extension cord which will mate directly with 

the power source receptacle and the air 

compressor power cord without the use of 

adapters. Make certain that the extension 

Summary of Contents for 815002013978

Page 1: ...ufactures products for safe operation However operators and maintenance per sons are responsible for maintaining safety All safety precautions are included to provide a guideline for minimizing the po...

Page 2: ...on 5 Area 5 Electrical Safety 5 Operation 6 Safety Rules 6 Air Tool Cautions 7 Power Source Connection 7 Power Requirements 7 Grounding Instructions 7 Connect to power source 8 Getting Started 8 Assem...

Page 3: ...ld up Safety Valve is preset at factory Do not attempt to make any adjustments to the safety valve Periodically pull the ring on the safety WARNING The safety valve automatically relieves valve end to...

Page 4: ...persons who have read and understood these operating instructions to use this compressor Failure to follow the instructions procedures and safety precautions in this manual can result in accidents and...

Page 5: ...compressor for maintenance access and adequate airflow WARNING CAUTION Mount unit leaving a minimum of 15 inches 38 cm of clearance 3 Use shims to level compressor if installation area is not flat Th...

Page 6: ...e in horseplay with air hoses as death or serious injury may result 7 Make sure to provide adequate ventilation while operating the compressor If combustible WARNING substances are spilled clean up im...

Page 7: ...ust be repaired 10 Check for damage Check your tool regularly If part of the tool is damaged it should be carefully inspected to make sure that it can perform its intended function correctly If in dou...

Page 8: ...nsure that is working properly Pull the ring on the safety valve before each use to make sure the valve is functional Depending on the CFM draw of the tools being operated your new air compressor can...

Page 9: ...2 Check that the pressure switch is pointed up in the OFF position fig 9 0 3 Ensure that the power supply you are going to use is operating normally 4 Insert the power supply cord into the power supp...

Page 10: ...ove the pressure switch clockwise to the OFF position fig 9 0 2 Unplug the compressor from the electical power 3 If not draining the tank reduce tank pressure through the air hose 4 Drain the tank by...

Page 11: ...e un loader valve plug and clean the valve seal If damaged replace seal and re install Compressor stopped and will not re start 1 Thermal overload protector has engaged due to motor overheat ing 1 Che...

Page 12: ...2 31 Self tapping screw 4 32 Fan 2 33 Outside spring 2 34 Crank throw 2 35 Stator 1 36 Rotor 1 37 Bearing 2 No Description Qty 38 Outside spring 2 39 Capacitor 1 40 Bolt 2 41 Capacitor cover 1 42 Bol...

Page 13: ...13 HP15P005SS man v 171212 Air Compressor Schematic Drawing...

Page 14: ...nty does not apply to defects due directly or indirectly to misuse abuse negligence or accidents repairs or alterations and lack of maintenance HULK shall not be liable for death injuries to persons o...

Page 15: ...15 HP15P005SS man v 171212 Air Compressor...

Page 16: ...16 HULK Power...

Page 17: ...nt s curitaire Cependant les op rateurs et les personnes charg es de l entretien sont responsables du maintien de la s curit Toutes les pr cautions de s curit sont incluses pour fournir une ligne dire...

Page 18: ...e 21 S curit lectrique 22 Op ration 22 R gles de s curit 22 Pr cautions sur l outil pneumatique 23 Alimentation de la source 24 Exigences d alimentation 24 Instructions de mise la terre 24 Raccordemen...

Page 19: ...ger l quipement et des blessures ventuelles 2 R SERVOIR r servoir de deux gallons 7 6 litres 3 PATTES DE CAOUTCHOUC r duit les vibrations et les mouvements du compresseur ATTENTION 4 SOUPAPE DE S CURI...

Page 20: ...indique une situation dangereuse imminente qui si elle n est pas vit e entra nera la mort ou des blessures graves Attention indique une situation potentiellement dangereuse qui si elle n est pas vit e...

Page 21: ...rateurs et autres personnes autour du compresseur et de DANGER ses commandes sont conformes toutes les r glementations codes et normes OSHA f d raux provinciaux et locaux applicables aux quipements d...

Page 22: ...le moteur du compresseur 7 Assurez vous d installer des disjoncteurs et des fusibles de taille appropri e DANGER DANGER 8 L appareil doit tre correctement mis la terre NE PAS connecter le fil de terre...

Page 23: ...uits chimiques de l huile etc ATTENTION ATTENTION 13 V rifiez l tat des tuyaux avant chaque utilisation N utilisez pas de tuyau endommag Si le tuyau est endommag remplacez le imm diatement 14 Lire et...

Page 24: ...ant alternatif monophas AC 120 volts 60 Hz correctement connect s avec un disjoncteur retard de 15 amp res Il est recommand qu un lectricien qualifi v rifie la TENSION R ELLE au r ceptacle dans lequel...

Page 25: ...allation et localisation Placez le compresseur dans un endroit propre sec et bien ventil Le compresseur doit tre plac 12 ou 18 pouces 30 45 cm des murs ou toute autre obstruction qui interf rerait ave...

Page 26: ...allez utiliser fonctionne normalement 4 Ins rez le cordon d alimentation dans la prise d alimentation 5 Mettez le pressostat sous tension d placez le levier vers la position AUTO fig 9 1 6 Sur la jau...

Page 27: ...inhabituels 2 Assurez vous que tous les crous et boulons sont serr s Apr s chaque utilisation goutter la condensation du r servoir d air Mensuel Inspectez le syst me d air pour les fuites en appliquan...

Page 28: ...eut provoquer une surchauffe du moteur Laissez le mo teur refroidir 2 Enroulement du moteur serait brul 2 Contacter le service la client le Le moteur ne d marre pas et fait un bourdonnement Condensate...

Page 29: ...x d fauts caus s directement ou indirectement par une mauvaise utilisation un abus une n gligence ou des accidents des r parations ou des modifications et le manque de maintenance HULK ne sera pas res...

Page 30: ...is autotaraudeuse 4 32 Ventilateur 2 33 Ressort ext rieur 2 34 Coude de vilebrequin 2 35 Stator 1 36 Rotor 1 37 Roulement billes 2 No Description Qt 38 Ressort ext rieur 2 39 Condensateur 1 40 Boulon...

Page 31: ...31 HP15P005SS man v 171212 HULK Power Dessin sch matique...

Page 32: ...32 Compresseur air...

Reviews: