emaux 9042901 Installation And Operation Manual Download Page 10

(3) Code learning operation between remote controls: Used to unify system code values or copy a new remote controls.

Since each remote controller has its own unique code at the time of deliver y, when there are multiple remote controllers 

in one system, one of them (for example, remote controller A) must be selected as the system code value, and the code 

value of the rest remote controllers (for example, remote controller B) should be copied to the same one.

Step

Operation

Instructions

1

A remote control

Press and hold “ON” on the remote control 

for 5 seconds, the indicator of the remote control will flash 
quickly, means it enters the pairing code transmission status.

Will automatically exit code transmission 
status after 60 seconds, or pressing any key 
to exit.

2

B remote control: long press "mode key" for 5 seconds, the 
remote indicator light changes from 100% light to 5% light 
and flash, means entering the code value receiving state

Will automatically exit the code value 
receiving state after 30 seconds, or exit after 
learning the code value successfully.

3

see the B remote control indicator light flash 3 times

Code copying is finished and exit code value 
receiving status.

(4) (4) Copying code from receiver to remote control.

 A new remote control can also copy code from any one of the receivers in the whole system, after the successful 

operation, the new remote control can replace the original remote (if it is lost).

Step

Operation

Instructions

1

Cut off the power of receiver.

Which one will be controlled by remote.

2

Long-press "mode key" for 5 seconds, the remote indicator 
light changes from 100% light to off, means entering the 
code value receiving state.

Will automatically exit the code value 
receiving state after 30 seconds, or exit 
after learning the code value successfully.

3

Power on the receiver, will see remote control indicator 
light flash 3 times.

Code copying is finished and exit code 
value receiving status.

* For security of the system, the distance from remote control to the one receiver should be less than 2 meters in this 
operation.
*Only one time operation is requested for the whole system, no need different operation for different zones.
 
(5) The remote control restores the factor y setting: it means that the remote control will be restored to the factor y's 
unique code value.

Step

Operation

Instructions

1

Long press "mode " for 20 seconds.

The remote indicator light dim down and 
flashes continuously until the 20th second 
and then back to 100% light. Means this 
step is finished.

2

Press the "OFF" to confirm, the remote indicator light 
flashes 3 times.

Restore factor y settings successfully.

7.1.4 Remote control accessories installation instructions

Accessories include bracket 1pc, 3M foam sponge glue 1pc, screw 2pcs, expansion tube 2pcs.
There are 2 options for bracket installation:
1) Using screw and expansion tube make drilling installation (suitable for uneven and ash surface);
2) Using 3M foam sponge glue make free drilling installation (suitable for flat no ash surface).

P9    DIMMER AND REMOTE OPERATION

Summary of Contents for 9042901

Page 1: ...USER MANUAL GLOW LED STRIP Installation and Operation Manual EMLI22080103...

Page 2: ...2 4 POWER SUPPLY AND DIMMER 4 4 MOUNTING 6 5 ELECTRICAL INSTALLATION 7 DIMMER AND REMOTE OPERATION 7 2 1 SPECIFICATION 7 2 2 CONTROL METHOD 7 2 3 CONNECTION PORT INSTRUCTION 7 2 4 DIRECTION FOR USE 7...

Page 3: ...solvents and dirt etc There are seven type of wiring connectors are providing mounting flexibility for layout connections PRODUCT INTRODUCTION P2 2 SPECIFICATION Operation Voltage Range DC24V Max Pow...

Page 4: ...ltage IP67 24V 120W 100 240V AC 50 60Hz input voltage IP67 Code E042901 106328534 106328535 Description Not in scale Dimmer with Remote Handset 24V DC power supply provides LED strip power source and...

Page 5: ...for better installation convenience change the connector model to GL10BD for both side straight connector and GL10SD for single end straight connector GL10BD GL10SD length m Code 10m color temp 3000K...

Page 6: ...el Mounting Clip 5cm DIY End Connector Kit Code GLPMC GLPMC1M GLSMC GLDIYSC Description Good mounting example Bad mounting example Installation direction GLPMC GLSMC 10mm 10mm Installation direction I...

Page 7: ...r Supply Black GNG Red 24V AC Mains Waterproof Connector 24VDC wiring diagram GLOW LED STRIP 2 Wiring diagram with dimmer 6 HOW TO USE GLDIYSC TO CUT THE STRIP AND END CAP ASSEMBLE If it is necessary...

Page 8: ...n flex Step 5 Screw the blank end to the aluminum mounting piece Step 1 Step2 Step3 Step4 Step5 finished assemblyview Code 106090030 Description LED Neon Cutter Model GLCUTTER 7 DIMMER AND REMOTE OPER...

Page 9: ...roller Ste Operation Instructions 1 Connecting the load to the receiver and power on it 1 It is necessary to clear the code first if the receiver was coded before 2 Batch operation can be performed wi...

Page 10: ...is lost Step Operation Instructions 1 Cut off the power of receiver Which one will be controlled by remote 2 Long press mode key for 5 seconds the remote indicator light changes from 100 light to off...

Page 11: ...follows Clockwise rotation to brighten up brightness to 100 as the maximum Counter clockwise rotation to dim down the brightness to 0 as the minimum PWM display P005 500Hz P010 1KHz P020 2KHz factory...

Page 12: ...YOUR PREMIER SUPPLIER www emauxgroup com EMAUX WATER TECHNOLOGY CO LTD...

Reviews: