P7 INSTALLATION
If the RCD/GFCI device trips, it means there is fault on the power line or motor. Do not use
this pump. Disconnect the pump and have the problem corrected by a qualified ser vice
representative before using. Press the reset button to reset the RDC/GFCI devices after
fixing. If the power line problem is not fixed it will keep the circuit shut off and will not
reset.
It is recommended to test the RCD/GFCI at least once a month.
P7 INSTALLATION
RCD NEMA GFCI Receptacle NEMA GFCI Breaker
This is a 380Vac (+10% - 6%) 50/60Hz three-phase pump.
Unscrew the terminal box at the top of the pump. There are four terminals labelled as U1, V1, W1 and T (EARTH).
Connect the power wires to these terminals according to the electrical code.
UPH550/UPH700
Delta Connection
UPH400
WYE/STAR Connection
5. START UP
1. Verify the pump shaft turn freely.
2. Check that the mains voltage, current and frequency correspond with the name plate.
3. Never let the pump run dr y! Running a pump dr y may cause damage the mechanical seal
causing leakage and flooding.
4.
Fill the pre-filter with water before starting the motor.
5.
Before removing the pre-filter lid, STOP PUMP, CLOSE GATE VALVES in suction and discharge pipes.
6.
Always STOP THE PUMP before when RELEASING ALL PRESSURE from the pump and the piping system.
7.
Never tighten or loosen screw while the pump is in operation.
8.
The suction pipe and the suction inlet in the pool must be free from obstruction.
Tighten/untighten the pump Lid by hand only.
Ear
th
Ear
th