AIR CONDITIONER

SPLIT WALL-MOUNTED

I N S T A L L A T I O N   I N S T R U C T I O N S

MODEL

S: WS 090C / WS 0

90

H

 / WS

100H

EMAILAIR

Summary of Contents for WS 090C

Page 1: ...AIR CONDITIONER SPLIT WALL MOUNTED I N S T A L L A T I O N I N S T R U C T I O N S MODELS WS 090C WS 090H WS100H EMAILAIR ...

Page 2: ...s 4 Unit location should not disturb neighbors with noise or exhaust air stream 5 Place the mounting pads under the unit legs 6 Install the outdoor unit as shown Refer to the technical and service manual for allowed distances 7 When the unit is installed on a wall install the drain connector hose as shown Fig 1 1 Bottom of outdoor unit 2 Drain connector Fig 2 Drain installation example ACCESSORIES...

Page 3: ...Fig 3 1 To attach 2 To remove Fig 4 1 Mounting pads x4 Fig 3 Fig 4 ...

Page 4: ...ONT INDOOR UNIT Removal of the right cover 1 Remove screw caps 2 from cover 1 2 Remove the three screws 3 3 Rotate the right cover to remove it Removal of the bottom cover 1 Remove screw caps 5 from the air outlet 2 Loosen the screws 6 of the air outlet 3 Pull the cover 4 down and then to the right to disengage it ELECTRICAL REQUIREMENTS 3 4 Fig 5 INSTALLATION OF THE MOUNTING RAIL 1 Figure 7 shows...

Page 5: ...densed or rain water from penetrating back into the room 3 Trim the hole in the wall with a ø70 mm commercial plastic tube Fig 8 4 When installing the drain hose avoid traps and U bends The end of the drain hose should not be immersed in water Fig 10 1 Trap 2 U bend 3 End immersed in water 5 For a lefthand outlet lay the drain hose on the bottom of the indoor unit rear groove Fig 11 1 Electric cab...

Page 6: ...ig 14a Fig 14b and Fig 14c Be sure to match the colored wires with the numbers shown on the indoor and outdoor unit terminal boards 4 Connect the yellow green ground wire to the ground terminal screw 5 Secure multiple wire power cable with the cable clamps 6 Fasten the twin wire cable to the power cable with cable ties Cooling only model For units above 10 KW THREE PHASE MODELS Fig 13 1 Terminals ...

Page 7: ...Torque wrench 3 Union Fig 18 1 Suction valve 2 Service port 3 Liquid valve Fig 17 To prevent refrigerant leakage coat the flared surface with refrigeration oil Fig 16 Fig 17 Fig 18 EVACUATION OF THE REFRIGERATION TUBES AND THE INDOOR UNIT After connecting the unions of the indoor and outdoor units purge the air from the tubes and indoor unit as follows 1 Connect the charging hoses with a push pin ...

Page 8: ...between hole sides and tubing with sealer 3 Attach wiring and tubing to the wall with clamps where necessary 4 Operate the air conditioner together with the customer and explain all functions 5 Explain filter removal cleaning and installation 6 Give the operating and installation manuals to the customer 8 ...

Page 9: ...d 4108 Tel 07 3274 4177 Fax 07 3274 4152 TOWNSVILLE 1 5 Everett Street PO Box 149 Bohle Townsville Qld 4818 Tel 07 4774 6552 Fax 07 4774 4967 OSBORNE PARK 19 Howe Street Osborne Park WA 6017 Tel 08 9244 5699 Fax 08 9244 5437 ADELAIDE Suite 27 8 Greenhill Road Wayville SA 5034 Tel 08 8372 7866 Fax 08 8372 7816 ECP AUSTRALIA PTY LTD ACN 082 755 655 HEAD OFFICE VICTORIA NEW SOUTH WALES QUEENSLAND WES...