MSE-218SP User Manual 

v1.1 February 2013 

 

To use the M20 threaded flange adapters, use a telescopic distance pole such as the EM 
Acoustics  DP-01.    Screw  the  threaded  end  into  the  flange  adapter,  making  sure  it  is 
screwed in completely.  Then, carefully lift the fullrange loudspeaker onto the pole. 

6.0 - Servicing Information 

Your EM Acoustics loudspeakers have been rigorously tested before they leave our factory, 
to  ensure  that  they  give  you  a  lifetime  of  flawless  operation.    Should  any  of  your  drive 

units fail and need replacing, please follow the guidelines below. 

MSE-218:  Low Frequency Drive Unit 

1.

 

Using a PZ2 Pozidrive screwdriver, undo the screws securing the front grille in place.  
Gently remove the grille from the front of the enclosure. 

2.

 

Using a 5mm Allen key, remove the eight M6 socket-head bolts holding the required 
drive unit in place.  Gently lift the drive unit out of its locating hole – please take care 
as it is heavy!  Carefully disconnect the cables from the drive unit. 

3.

 

To  reinstate  the  driver,  simply  reverse  the  above  procedure.    Please  observe  the 
correct polarity – red cable to positive terminal, black cable to negative. 

4.

 

Reinstate  the  grille  by  gently  placing  it  in  place  over  the  front  of  the  loudspeaker.  
Replace the PZ2 screws to secure the grille in place. 

Summary of Contents for MSE-218SP

Page 1: ...oustics Loudspeakers Building 74 Dunsfold Park Cranleigh Surrey GU6 8TB UK Phone 44 0 1483 266520 Fax 44 0 1483 275619 www emacoustics co uk ___________________________________________________________...

Page 2: ...Page 9 3 5 Powering Up Page 10 Electrical Safety Issues Page 10 4 0 Amplification and Audio Page 11 4 1 Audio Inputs Page 11 4 2 Linking Audio Signals Page 12 4 3 DSP Menu Structure Page 12 4 4 Remote...

Page 3: ...se harmful interference 2 This device must accept any interference received including interference that may cause undesired operation RECYCLING This product and its packaging constitute the applicable...

Page 4: ...remain freely accessible at all times Unplug the loudspeaker from the mains power supply during electrical storms or when unused for long periods of time Disconnect the mains plug before disconnectin...

Page 5: ...power line surges Disconnection from the mains power supply can only be achieved by removing the plug from the mains socket and by external disconnection of all poles from the mains INTERFERENCE OF E...

Page 6: ...ORTANT When disconnecting this product from mains power always disconnect the mains end first before disconnecting the PowerCON connector Similarly when connecting this product always connect to the l...

Page 7: ...d you should be congratulated for purchasing one of the finest loudspeaker products on the market today This manual contains all the information you should need on topics of set up connection flying s...

Page 8: ...and touring applications The reflex design utilizes a pair of powerful 4 5 voice coil 18 457mm neodymium LF drive units in an incredibly rigid and rugged enclosure Various features have been incorpora...

Page 9: ...or and as such you must ensure the total load does not exceed 20 amps 3 3 AC Link Connector GREY The grey Neutrik PowerCON connector supplies mains power to additional loudspeakers in the chain The Po...

Page 10: ...lifier to detect a fault and require resetting Electrical Safety Issues Please pay close attention to the following electrical and safety issues a The MSE 218SP requires a grounded mains outlet Always...

Page 11: ...one module per drive unit providing ample power to drive your loudspeakers to their full potential The amplifier and DSP combination also provides full limiting and remote monitoring 4 1 Audio Inputs...

Page 12: ...name on the top line and the currently selected program on the bottom line Adjusting parameters via the MENU key or EDIT encoder will change the display to reflect the current function The output sig...

Page 13: ...anged by the user in the remote software on the top line and the loaded preset on the bottom line simply rotating the encoder will display the unit status in the following order INPUT GAIN INPUT DELAY...

Page 14: ...rds a cardoid subwoofer array can be created which offers significant low frequency rejection to the rear and sides of the array When using the MSE 218 in this way the two front firing subwoofers shou...

Page 15: ...ase follow the guidelines below MSE 218 Low Frequency Drive Unit 1 Using a PZ2 Pozidrive screwdriver undo the screws securing the front grille in place Gently remove the grille from the front of the e...

Page 16: ...8 4 kg lbs ENCLOSURE 18mm 3 4 multi laminate Birch plywood rebated screwed glued Finished in black semi matt textured paint RIGGING SUSPENSION 2 x M20 threaded flange adapters 8 x tour grade bar handl...

Page 17: ...120V AC 200 240V AC 50 60Hz NOMINAL CURRENT 4 8A RMS 230V 9 6A RMS 120V POWER COMSUMPTION 822W nominal 4800W maximum Notes on measurement conditions 1 Measured on axis at 2m in an anechoic environmen...

Page 18: ...1 1 February 2013 Appendix B Accessories Spare Parts List 01A022 DU 1802 18 neodymium LF drive unit 4 ohms 01C019 RK 1802 4 ohm recone kit for DU 1802 04A024 RG 218 Replacement steel grille 10E217 TC...

Page 19: ...on any misrepresentation by the seller Products which contain anything other than the original components or EM Acoustics factory supplied spare parts Products on which the serial number has been rem...

Page 20: ...ive components and as such are not liable for any incidental and consequential damages including without limitation injury to persons damage to property or loss of use This warranty is exclusive and n...