EM TEST
coupling NX
Manual of operation
V 1.03
17 / 53
5.2.
Rack with built in coupling NX5-bs-480-125
5.2.1. Front and rear view coupling NX5-bs-480-125
Figure 5.3: Test system with compact NX5, coupling NX5 (model for EUT 3 x 480V /125 A)
1
Generator compact NX5
2
Front coupling NX5-bs-3-480-125
3
EUT output L1, L2, L3, N, PE; 6mm
4
Reference ground plate for table top EUT
5
Power ON switch
6
Ref GND plate for floor standing EUT
7
Lock for open the rack
8
Ref GND plate for floor standing EUT
1
Generator compact NX5
Generator compact NX5 for generate burst and surge impulses.
2
Front coupling NX5-bs-3-480-125
Indication LED and output plugs of the coupling NX5 bs-3-480-125. See the previous chapter
view coupling NX5 bs-3-480-16 / 32
3
EUT output L1, L2, L3, N, PE; 6mm
Input plug for the EUT power supply (6 mm safety banana plug up to 125A). The input is not fused.
- L1, L2, L3: Mains voltage to EUT phase L1 to L3
- N:
Neutral to EUT supply
- PE:
Protected earth to EUT supply
For more information concerning the connectors refer to the Annex in this manual
4
Reference ground plate for table top EUT
Reference ground plate for table top test equipment. Use a low inductance cupper foil or braid to connect the
reference ground of the table to the test rack.
5
Power ON switch
Main switch to power on the test system (equipment and the EUT supply).
For power ON the EUT press the Test ON button for release the supply to the EUT
6
Ref GND plate for floor standing EUT
Front side reference ground plate for floor standing test equipment. Use a low inductance cupper foil or braid to
connect the reference ground of the reference GND to the test rack.
7
Lock for open the rack
Rotate the two screws for open the rear of the rack.
8
Ref GND plate for floor standing EUT
Rear side reference ground plate for floor standing test equipment. Use a low inductance cupper foil or braid to
connect the reference ground of the reference GND to the test rack.