4.1 Assembly Instructions

•  Make certain the 

fi

 tting is suitable for the relevant ap-

plication. The 

fi

 tting must be suitable for the operating 

conditions of the pipeline system (medium, concentra-
tion, temperature and pressure) as well as the relevant 
ambient conditions.

• Check the 

fi

 tting for transport damage before installing 

it. If the 

fi

 tting is damaged do not install it.

• The planner, the construction company or operating 

company are responsible for the positioning and instal-
lation of the 

fi

 tting. Planning and installation errors can 

adversely affect the reliable functionality of the 

fi

 tting 

and may represent a signi

fi

 cant potential for hazard.

• After the 

fi

 tting is installed perform a tightness and 

function check.

4.2 Tools Required

The tools required for installation and assembly are not 
included with delivery.

4.3 Connect Mounting Filter

• The 

fi

 tting must be connected to the pipeline so it is 

free of mechanical stress.

•  The Filter has a female thread (ISO, DIN, ANSI) and/or 

a tube connections and can be connected with various 
connecting elements of the 

em

technik system.

Cylindrical thread

Conical thread

Sealing is provided by a sealing collar for 

Cylindrical threads (G, M or UNF).

 A version with an O-ring is also possible.

Sealing is provided 

by the thread itself 

for Conical threads 

(NPT).

Sealing Collar

O-Ring

Thread

•  Each thread must always be connected with the same 

thread type.

•  If a plastic 

fi

 tting is used in combination with a metal-

lic male 

fi

 tting, additional sealing with Te

fl

 on® tape is 

recommended.

4.4 Torque Chart

Plastic

Thread

G 1/8“

G 1/4“

G 3/8“

G 1/2“

G 3/4“

PVDF

1.0–2.0

5.0

5.0–7.0

10.0

15.0

PTFE

0.3

0.5

1.0

2.5

5.0

4.5 Fastening Options

For the Filters are no fastening options intended.

5 Commissioning

5.1 Precondition for Commissioning

• Protect against leaks: Take protective measures 

against exceeding the maximum permitted pressure 
due to possible pressure surges.

•  Check the tightness and function of the 

fi

 tting.

•  In new systems and after repairs, 

fl

 ush the line system 

to remove foreign materials.

6 Maintenance

• When used as designated, the 

fi

 tting is practically 

wear-free and generally requires no maintenance.

• The operating company must perform regular visual 

inspections of the 

fi

 tting according to the operating 

conditions to prevent leaks and damage.

7 Disposal

• When disposing of the 

fi

 tting and packaging, comply 

with the relevant disposal requirements and environ-
mental protection regulations.

• When disposing of 

fi

 ttings, pay careful attention to any 

residues of toxic or corrosive media.

8 Return Delivery

Do not return before consulting with 

em

technik.

1. Please consult with 

em

technik.

2. Empty the 

fi

 tting properly.

3. Rinse and clean the 

fi

 tting thoroughly, especially if the 

media is being conveyed are harmful, explosive, hot, 
or hazardous in some other way.

4. For 

fi

 ttings that have been operated with aggressive, 

corrosive, combustible, toxic or water polluting media, 
a completely 

fi

 lled in clearance certi

fi

 cate must always 

be included.