4.2 Tools Required

The tools required for installation and assembly are not 
included with delivery.

4.3 Connect Thread Side

•  The  connector  must  be  connected  so  it  is  free  of 

mechanical stress.

•  The connector can have a male or female thread (ISO, 

DIN, ANSI) and can be connected with various connec-
ting elements of the 

em

technik system.

Cylindrical thread

Conical thread

Sealing is provided by a sealing collar for 

Cylindrical threads (G, M or UNF).

 A version with an O-ring is also possible.

Sealing is provided 

by the thread itself 

for Conical threads 

(NPT).

Sealing Collar

O-Ring

Thread

•  Each thread must always be connected with the same 

thread type.

•  If a plastic connector is used in combination with a me-

tallic male fi tting, additional sealing with Tefl on® tape is 
recommended.

4.4 Torque Chart

Plastic

Thread

G 1/8“

G 1/4“

G 3/8“

G 1/2“

G 3/4“

PP

1.0–1.5

2.5

5.0–6.0

5.0

10.0

PVDF

1.0–2.0

5.0

5.0–7.0

10.0

15.0

All data in Nm

4.5 Connect Tube Side

•  Push the fl exible tube onto the barb by hand. This wi-

dens the tube and locks and holds it in place. In additi-
on, the tube can be secured against slipping by means 
of a pipe clamp.

4.6 Fastening Options

For the connectors are no fastening options intended.

5 Precondition for Commissioning

•  Protect  against  leaks:  Take  protective  measures 

against  exceeding  the  maximum  permitted  pressure 
due to possible pressure surges.

•  Check the tightness and function of the connector.
•  In new systems and after repairs, fl ush the line system 

to remove foreign materials.

6 Maintenance

•  When used as designated, the connector is practically 

wear-free and generally requires no maintenance.

•  The operating company must perform regular visual in-

spections of the connector according to the operating 
conditions to prevent leaks and damage.

7 Disposal

•  When  disposing  of  the  connector  and  packaging, 

comply  with  the  relevant  disposal  requirements  and 
environmental protection regulations.

•  When disposing of connector, pay careful attention to 

any residues of toxic or corrosive media.

8 Return Delivery

Do not return before consulting with 

em

technik.

1. Please consult with 

em

technik.

2. Empty the connector properly.
3. Rinse and clean the connector thoroughly, especially 

if the media is being conveyed are harmful, explosive, 
hot, or hazardous in some other way.

4. For connectors that have been operated with aggres-

sive,  corrosive,  combustible,  toxic  or  water  polluting 
media, a completely fi lled in clearance certifi cate must 
always be included.