ADR4
Installation Manual
EMM_871_4956
Rev 2.8
EM Motorsport Ltd. CONFIDENTIAL PROPRIETARY. All right reserved
6/20
Tags
Description
sampling
frequency
gain
unit
Timer
Supercap hold timer at power
removal
10Hz
0.1
s
PowerUp
number of unit power ups
0 Hz
1
--
Table 2
–
ADR 4 internal channels
2.3
System set up
It is possible to connect to the serial port of the unit to setup some parameters such as time
or orientation. There are 2 different methods to connect to the unit:
-
ADR4 Display: EM Motorsport GUI tool that allows the user to visualize and edit ADR
parameters. This tool can be downloaded in our portal, listed in Chapter 7 -
-
External Serial Console: Any external serial console (i.e: PuTTy), also allows the user to
edit ADR parameters by using the commands listed in 2.3.2.
2.3.1
Connection set up
The serial port has the following parameters:
Protocol:
RS232
Speed:
115200
Bits:
8
Parity:
N
Start bits:
1
2.3.2
List of available commands:
2.3.2.1
FIA reserved:
Password
: command to unlock following commands otherwise not actuated.
AccidentTmeThd
: sets the accident detection duration threshold, default value 5ms.
AccidentThdX:
sets the accident detection acceleration threshold for X axis, default
value 15G.
AccidentThdY
: sets the accident detection acceleration threshold for Y axis, default
value 15G.
AccidentThdZ
sets the accident detection acceleration threshold for Z axis, default
value 25G.
AccidentPostTD
: sets the minimum accident post trigger time.
2.3.2.2
Setting RTC:
The following commands are used to set the battery back-up RTC
SetRTC
: enter the date and time in the following format
Format: dd/mm/yyyy,hh:mm:ss
SetDate
: enter the date in the following format
Format: dd/mm/yyyy
SetTime
: enter the time in the following format
Format: hh:mm:ss
SetTimeGPS:
Command will only work when VBatt is applied, would set the unit time
to GPS time.