background image

3

Compatibility

The xfilter 500 module requires installation into an API 500 se-

ries compatible rack frame (not included). It needs the power 

supply and the audio connectors provided by this frame, and 

cannot be used for its intended purpose by itself.

The  current  consumption  is  210  milliamperes  (105  mA  per 

slot) at +/- 16 volts DC. This is actually more than some other 

500 series modules consume as a result of the class-A design 

of the audio path of the xfilter 500.

Most API 500 compatible racks meet this requirement with-

out problems, but there might be a limit on how many units 

can be installed in a single rack. In case of doubt, please check 

with the manufacturer of your specific rack.

Installation

Just follow these easy steps to install the xfilter 500 module:
1.  Switch your API 500 series compatible rack off and discon-

nect the power cable from mains.

2.  Insert the module into two free slots of your rack. Make sure 

both PCB connectors match with the rack connectors.

3.  Gently push the module in place – do not use any excessive 

force!

4.  Tighten the front panel with four screws provided by your 

rack manufacturer.

5.  Connect your XLR audio cables (see page 6 for more info) 

and power up your rack.

That should do it. Have lots of fun with your xfilter 500!

Summary of Contents for xfilter 500

Page 1: ...xfilter 500...

Page 2: ...xibility It offers high and low shelf bands which can be switched into high and low cut filters with resonance two mid peak filters with wide and narrow Q plus additional passive LC stages with shield...

Page 3: ...oblems but there might be a limit on how many units can be installed in a single rack In case of doubt please check with the manufacturer of your specific rack Installation Just follow these easy step...

Page 4: ...Frequency Low Shelf Sets the frequency for the low shelf filter p 8 Gain Low Mid Boosts or cuts the low mid frequency range p 10 Frequency Low Mid Sets the center frequency for the low mid peak filter...

Page 5: ...D off p 7 Low Cut Switches the low shelf filter LED off into a low cut filter with resonance LED on p 8 Narrow Q High Mid Changes the Q factor of the high mid filter from a wide curve LED off to a nar...

Page 6: ...idle Audio inputs 4 dBu Pin assignment balanced 1 ground 2 hot 3 cold Pin assignment unbalanced 1 ground 2 hot 3 ground Mono operation Connect either input and output 1 or 2 both will work identicall...

Page 7: ...a switchable fixed LC filter for polishing the high frequency range The filter mainly consists of a capacitor and a coil per channel but unlike the standard shelving designs it has a slight reso nance...

Page 8: ...8 Low Shelf Low Cut...

Page 9: ...9 High Shelf High Cut...

Page 10: ...10 Low Mid Wide Q Low Mid Narrow Q...

Page 11: ...11 High Mid Wide Q High Mid Narrow Q...

Page 12: ...E Conformity elysia GmbH Ringstra e 82 41334 Nettetal Germa ny declares with sole responsibility that this product complies with the following norms and directives 2006 95 EG Low Voltage Directive for...

Page 13: ...er service to qualified service staff only CAUTION Temperature Surfaces of the device may become hot during operation Do not install this device near any heat source such as radia tors stoves or other...

Page 14: ...ct has been dam aged by misuse accident neglect modification tampering or unauthorized alteration by anyone other than elysia autho rized service personnel The warrantor assumes no liability for prope...

Page 15: ...his document is subject to copyright All rights technical changes and errata are reserved No part of this manual may be reproduced or transmitted in any form or for any purpose without the explicitly...

Page 16: ...elysia GmbH Ringstra e 82 41334 Nettetal Germany 49 2157 126040 info elysia com...

Reviews: