background image

3

EN

-  Interchangeable cards for quick maintenance.

-  Removable terminal blocks.

POWER SUPPLY OPERATING MODES

-  Selector set A-B:

-  “A” Position: operating with sound system call, to be used in 

case of  summing noises (caused by power supply, door lock or 

lamps) dectected on the interphone line.

-  “B” Position: normal operation with Sound System call, swi-

tching module in “A” position only in case of summing noises on 

the audio line.

-  “B” Position: operating with 15V A.C. call only. In this case 

power supply 6680/C17 completely replaces power supply type 

6580. 

PROTECTION OF POWER SUPPLY:

-  Primary coil of transformer by PTC SIEMENS C830

-  1st. secondary coil for internal electronic supply by F 3,15A 

250V (F1) fuse.

-  2nd. secondary coil for lock supply by PTC SIEMENS C945

-  Electronic protection against short-circuits and overloadings on 

monitor cable riser.

-  Electronic protection against overloadings to outdoor unit.

ADJUSTMENTS

P1 - Activation time adjustment for monitor and camera.

P2 - Volume adjustment of speech unit.

P3 - Activation time adjustment for electric lock.

N.B.: The electric door lock must operate by way of an inter-

mittent cycle so that one 

operating period corresponds to 5 rest periods, thereby pre-

venting the protection 

device from overheating (one period corresponds to the door 

lock activation time).

Dimensions type  6680/C17 - 6680/C17/V03: 208x135x72 - 

Weight: 1.4 Kgs.

Removable terminal blocks

Selector A-B

OPERATION

The video door entry installation consists of one camera entrance 

panel with speech unit, one power supply and one or more moni-

tors.  The system can operate with monitors and B/W or colour 

cameras and with or without conversation privacy.

The power supply is not equipped with intercommunicating 

section; nevertheless it is possible to carry out a monitor and/or 

intercommuicating interphones network using switching module 

type 935A in conjunction with the basic power supply.

When an entrance panel push-button is pressed, the chime rings 

in the corresponding apartment. Almost immediately the imageof 

the caller appears on the monitor. The coverage area is illumina-

ted by built-in infrared leds when using B/W camera, or by a built-

in white light when using a  colour camera.

If desired, the user may simply raise the interphone, communicate 

with the caller and, if appropriate, activate the door-opener. In 

this case, door-opening time may be varied from 1 to 30 seconds 

using the potentiometer P3. 

The system turns itself off automatically after a preset time, adju-

stable from 30 to 90 seconds using potentiometer P1 inside the 

power supply. If the caller presses another user’s push-button, 

the previously called monitor is automatically disactivated without 

waiting for the end of the preset time. When testing the installed 

system, use trimmer P2 to adjust the optimal volume of the spe-

ech unit. For simultaneous activation of two or ore monitors one 

extra power supply type 5582/C17 must be installed for each 

additional monitor or type 6583 for more monitors. A blocking 

circuit cuts off power to monitors if the line is overloaded or 

short-circuited. The power supply is also equipped with a specific 

device to eliminate any buzzing on the voice circuit caused by the 

use of wires that are too long and/or too thin only in installations 

with “SOUND SYSTEM” call. Push-buttons with name-tags are 

illuminated through output 0-15 on power supply. Up to a maxi-

mum number of three 24V 3W bulbs can be connected. An addi-

tional transformer, type  M832 or 832/030 is required for entrance 

panels with more bulbs. 

Technical specifications of power supply type  6680/

C17 - (6680/C17/V03)

Type 6680/C17 is the basic power supply for all video door entry 

systems with SOUND SYSTEM call and is equipped with an 

electronic double tone generator, which replaces conventional 

alternative calling with a buzzer or bell. The sound is emitted with 

two different tones (present on terminals C1-C2) thereby allowing 

the user to immediately identify the source of the call (main 

entrance, gate, garage, etc.). This feature provides economic and 

pratical advantages since the use of several conventional sound 

emitting systems is no longer required; the signal is emitted from 

a single loudspeaker in the interphone. In some cases, savings 

can be made on the cable routing work requirements for additio-

nal bell systems. Manufactured in technopolimer class V-0 hou-

sing; preset for mounting on cases with 12-Module DIN support or 

with expanding plugs with screws.

-  117V A.C. 60Hz supply  (other voltages on request) with polari-

zed plug

-  60VA maximum absorbed power.

-  Dissipated power: 15W

-  18V D.C. 0.8A monitor supply (90 sec. ON, min. 90 sec. OFF)

-  13V D.C. 0.3A camera supply (90 sec. ON, min. 90 sec. OFF)

-  15V rectified voltage 0.25A continuous duty for push- button 

illumination (3x24V 3W max)

-  Door lock output: 15V A.C. 1A intermittent cycle, (30 sec. ON, 

min. 150 sec. OFF)

-  Amplified electric door-opener system.

-  Timer and automatic disconnection device of monitor previously 

activated.

Summary of Contents for 6680/C17

Page 1: ...Installer guide Art 6680 C17 Power supply 117V 60Hz 40W...

Page 2: ...being walked on or pinched parti cularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manu facturer 12 Refer...

Page 3: ...econds using the potentiometer P3 The system turns itself off automatically after a preset time adju stable from 30 to 90 seconds using potentiometer P1 inside the power supply If the caller presses a...

Page 4: ...ric lock BLUE SECT 1mm C1 Speech unit electronic call GREEN C2 Electronic call outside apartment door WHITE GREEN CONNECTIONS TO MONITORS INTERPHONES CONNECTION TO CAMERA ENTRANCE PANEL Coaxial cable...

Page 5: ...1 302 series B Additional door lock button C 12V electric lock D Camera with speech unit type 559 559A 559B 559G 558 570 570G 571 559C and 570C 930A L1 Led module for entrance panel 10 module LED max...

Page 6: ...der the cover to position A Mains A Video entrance panel 3300 8000 8100 1200 PATAVIUM and letter box 2550 301 302 series B Additional door lock button C 12V electric lock D Camera with speech unit typ...

Page 7: ...g module type 935A switches communication to internal only and so to continue the conver sation it is necessary to call again from the entrance panel IINTERNAL COMMUNICATIONS Lift interphone and press...

Page 8: ...on the audio line move the swi tching module A B located under the cover to position A INTERPHONE SETTING type 6200 6152 SECONDARY Fig 1 B W MONITOR type 6000 type 6200 type 6145 type 6152 COLOUR MON...

Page 9: ...6E 6P 4A 6S 4C 8 6P 6E 8 4C 6S 4A 6E 6P 8 4C 4A 6S 6P 6E 8 4C 6S 4A 6E 6P C3 AU 1 CH 2 3 S V 8 4A 6S 6P 6E 6E 4A 8 6P 6S 6E 6S 6P 8 4A 6E 4A 8 6P 6S 6E 4A 8 6S 6P 6E 4A 8 6P 6S 6E 4A 8 6S 6P 6P 6S 6E...

Page 10: ...6500 type 6501 type 6401 type 6321 type 6320 Power supply type 6582 C17 Mains Monitor cable riser To power supply type 6680 Interphone type 6200 Max 2 monitors type 6000 type 6003 To power supply type...

Page 11: ...can power two monitors Art 6000 6003 6300 6301 6303 or one monitor type 6320 6321 6500 6501 by connecting them as shown in the stan dard diagram For simultaneous switch on of more than one monitor it...

Page 12: ...V D C 2A with intermittent operation If a line with excessive voltage drops powers a single monitor you can use the power supply type 5582 C17 VERSION 4 Connection of call repeater type 0002 841 The l...

Page 13: ...7 5 4 8 B B C2 A B PRI 4 B 7 8 5 5 PRI 4 8 7 2 1 12 7 4 3 5 6 9 8 11 10 V 13 M 6 1 3 2 5 4 11 8 7 10 9 13 12 M V Additional bell type 860A Mains Additional bell type 860A Mains Interphone type 6200 A...

Page 14: ...ell Doorbell Power supply Monitor type 6301 type 6321 type 6401 type 6501 Mechanical doorbell RELAY type 0170 101 Maximum load 3A 230V Doorbell Power supply RELAY type 0170 101 Maximum load 3A 230V Mo...

Page 15: ...VARIATION 7 Wiring diagram for landing call button When the landing call push button is pressed the monitor sounds with a different tone from the tone generated by a call from the entrance panel The m...

Page 16: ...Maximum load 3A 230V AC Interphone type 6200 Monitor type 6000 type 6003 To switch on the stair light in this case press push button number 1 You can connect any one of the eight additional buttons o...

Page 17: ...type 6301 type 6320 type 6321 type 6303 type 6401 type 6500 type 6501 It is possible to activate the video system from the monitor using the push button with the symbol by connecting it to terminal 12...

Page 18: ...iagram of cameras type 558 571 with Videomoving device A 8000 1200 8000 3300 PATAVIUM or letter box series video entrance panels B Electric lock 12V AC C Camera type 558 571 930 D Additional door lock...

Page 19: ...6200 Monitor type 6000 type 6003 A Connection to user without monitor To power supply type 6680 Interphone type 8875 type 8872 Monitor type 6300 type 6301 type 6320 type 6321 type 6303 type 6500 type...

Page 20: ...200 6201 Open the interphone Fig 1 Snap off the plastic lamina by exerting pressure on it Fig 1B Insert the card in its seat and fix it with the screw supplied Fig 2 Disconnect the loudspeaker wire fr...

Page 21: ...0 With the lock open indicator connect only terminal N 8 of the interphone type 6200 As shown in the diagram use type 5582 C17 to power the LED s maximum 30 For more than 30 LED s use further addition...

Page 22: ...D max 30 module LED con Art M832 40 module LED con Art 832 030 Relay type 0170 001 Maximum load 3A 230V Power supply type 6680 C17 Mains Additional camera with waterproof housing type 5000 5020 5A20 5...

Page 23: ...used in the diagram are push buttons number 2 Pressing the 1st push buttons enables self start of the system without activating the ringtone If you keep the push button pressed down you will see the...

Page 24: ...8 6 AM 15 T C1 O S1 7 AU 2 1 6E 3 6S 4 8 C A 6 6E 5 6P CN1 AU 2 1 3 CN1 S PRI M1 V2 V1 M2 C2 AU 1 B A 3 2 S 6 8 7 O AM T 15 C1 S1 Power supply type 6680 C17 Mains 12 V A C electric door lock Interphon...

Page 25: ...coaxial cable or good quality cables with equivalent impedance It is advisable to install the amplifier near the power supply in a dry ventilated area It is possible to install the amplifier on the m...

Page 26: ...must be wired across video outputs V1 V2 V3 V4 These resistors must be wired to the output terminals not used or terminals V2 M on the last riser monitor A 75 Ohm resistor must also be wired to the V...

Page 27: ...6000 type 6003 5556 004 e 5555 75 Ohm resistors supplied must be wired across video outputs V1 V2 V3 V4 These resistors must be wired to the output terminals not used or termi nals V2 M on the monito...

Page 28: ...V4 75 ohm 75 ohm 3 V V V1 75 ohm V 5 5 6 U U 6 75ohm 75ohm 75 Ohm 75 Ohm Distributor type 5555 type 5556 004 Distributor type 5555 type 5556 004 Last distributor type 5556 004 type 5555 Monitor type...

Page 29: ...oltage between terminals and 5 and 6 should not be less than 15V D C Voltage between terminals T of camera should not be less than 11V D C Distorted or doubled image check if 75 Ohm load resistor is i...

Page 30: ...UNCTION OPERATION The power supply with the A B selector set at B does not take account of the note generator located internally and therefore makes the call to the monitor via terminal 15 15V ac Each...

Page 31: ...module A B located under the cover to position B A Video entrance panel 3300 8000 8100 1200 PATAVIUM and letter box 2550 301 302 series B Additional door lock button C 12V electric lock D Camera with...

Page 32: ...have a microswitch on the back set it to without conversation pri vacy N B The monitors have a microswitch on the back or underneath for connection with coaxial without coaxial set the microswitch to...

Page 33: ...4 4 3 3 2 2 1 1 PRI U C I 15 A B C CH O V 6 5 3 V 6 5 3 5 5 4 4 3 3 2 2 1 1 STANDARD VIDEO DOOR ENTRY SYSTEM WIRING DIAGRAM VERSIONS VARIANTE 1 Wiring diagram for simultaneous activation of two or mor...

Page 34: ...6 3 2 1 V STANDARD VIDEO DOOR ENTRY SYSTEM WIRING DIAGRAM VERSIONS VARIANTE 2 Wiring diagram of one interphone on a video door entry system A Single connection B Connection in parallel to a video door...

Page 35: ...RD VIDEO DOOR ENTRY SYSTEM WIRING DIAGRAM VERSIONS VERSION 3 Wiring diagram of video door entry system with SOUND SYSTEM call and ringtone type 6150 The electronic ding dong ringtone card type 6150 ca...

Page 36: ...Vimar SpA Viale Vicenza 14 36063 Marostica VI Italy Tel 39 0424 488 600 Fax Italia 0424 488 188 Fax Export 0424 488 709 www vimar com 49400806A0 00 1503 VIMAR Marostica Italy...