  NLJD  is  to  be  operated  only  by  persons  who  have  been  duly  instructed  for  safety 

measures while working with electric and measuring devices with open RF energy radiators. 

 

6. Operation Order 

6.1

. Remove NLJD from the package. If necessary charge the battery. After transportation at 

negative temperatures it is necessary to keep NLJD in the switch-off state at room temperature 
at least for 30 minutes. 

 

6.2

. Turn NLJD on by the type-slide switch placed on the arm. The 2

nd

 and 3

rd

 indicators on 

the control panel will light up, indicating that NLJD has been powered on. One  yellow LED 
should be lightning on the antenna unit (a circle scale of the probing signal power indicator). 
Its initial position corresponds to the maximum power of the probing signal in the automatic 
mode.  Here  the  probing  signal  transmitter  is  off  (it  is  turned  on  after  pressing  PWR  button 
only). The 2

nd

 and 3

rd

 harmonics indicators should not light (flashing of the first LEDs of the 

2

nd

 and 3

rd

 scales is permitted). Maximum power level can be changed using the power control 

buttons of the transmitter (Fig.5). 

6.3

.  Turn  the  probing  signal  transmitter  on  pressing  PWR  button.  This  will  switch  on  the 

transmitter  pulse  mode  and  the  automatic  mode  of  signal  power  control.  The  radiated  signal 
power will change depending on a signal level at the 2

nd

 harmonic receiver output. In the given 

mode acoustic information (clicks) of the 2

nd

 harmonic response is applied to the loudspeaker 

or earphones.  

When switching on 3-RD mode by pressing LST on the control unit, the output power of the 
transmitter is adjusted automatically depending on a signal level at the 3

rd

 harmonic receiver 

output.  Acoustic  information  of  the  3

rd

  harmonic  response  is  applied  to  the  loudspeaker  or 

earphones. 

To switch over to the manual mode of the probing signal power control (MNL indicator lights 
up) press one of the power control

 

buttons when the probing signal transmitter has been turned 

on.  

Turn  the  probing  signal  transmitter  off  and  then  turn  it  on  using  PWR  button  for  a  reverse 
switch over. 

If it is necessary to tap the 3

rd

 harmonic response turn on 3–RD mode using LST button on the 

control panel. 

During  operation  in  premises  with  a lot of electronic  devices  it  is  normally recommended  to 
work at decreased power of the probing signal. 

The optimum level of the probing signal is reached experimentally. 

Press  RF  button  to  switch  over  to  the  CW  mode  (CW  LED  lights)  from  the  pulse  mode 
(PULSE LED lights) and vice versa. 

6.4.

  Simultaneous  flashing  of  all  indicators  on  the  control  panel  indicates  that  the  battery  is 

discharged. In this case turn off the power, untwist a cover at the edge of the arm off, remove a 
battery, place it into the container and charge using the charger. 

6.5. 

If  a  response signal  is to be  tapped by  earphones, press  the corresponding button on  the 

control panel and turn the receiver on.  

Attention:  

1)  While  operating  NLJD

 

constantly  monitor  battery  state  charging  it  in-time  (by  the 

indicators signal). NLJD must be kept with a battery charged.   

2)  Charging  should  be  done  with  a  charger  included  into  the  delivery  set  only,  using  of 
unauthorized chargers are strongly prohibited.  

Summary of Contents for LORNET-24

Page 1: ...OM MP PA AC CT T H HA AN ND DH HE EL LD D N NO ON N L LI IN NE EA AR R J JU UN NC CT TI IO ON N D DE ET TE EC CT TO OR R L L O O R R N N E E T T 2 2 4 4 U US SE ER R M MA AN NU UA AL L C CE ER RT TI...

Page 2: ...ous wave carrier CW pulse modulated carrier with a duty cycle 44 pulse This enables to combine wide detection range and reliable identification of the devices found The output power automatic control...

Page 3: ...5 40 C pressure 450 800 mm of mercury 3 Delivery Set Design and Accessories 3 1 The device includes units and accessories stated in the Table 1 below Table 1 No Description Q ty 1 A duplex antenna un...

Page 4: ...to time thus selecting an optimal frequency automatically providing the best sensitivity and detection range of semiconductor components Generation UHF signal receipt and digital processing of the 2n...

Page 5: ...odes control and display LEDs are placed in the housing The control buttons are divided into two groups by their function AUDIO placed in the upper half of the panel and POWER RF in the lower half The...

Page 6: ...the red LED goes out and a green LED lights up Charging time of a fully discharged battery does not exceed 6 hours 4 6 Control elements of the receiver are shown in Fig 6 Fig 6 Receiver 4 7 Receiver O...

Page 7: ...ching on 3 RD mode by pressing LST on the control unit the output power of the transmitter is adjusted automatically depending on a signal level at the 3rd harmonic receiver output Acoustic informatio...

Page 8: ...on of the object under searching decrease the transmitter output power or receivers sensitivity using ATT button 7 5 When an artificial n transition is found one shall normally see stable lightning of...

Page 9: ...n the fields and on the cover of the Certificate 2 Delivery Set Table 1 No Description Q ty 1 A duplex antenna unit with a control panel and a built in container for a battery 1 2 Changeable Li Ion ba...

Page 10: ...cording to obligatory requirements of state standards current technical documentation and is fit for service Technical inspection __________ stamp date month year P A C K A G E C E R T I F I C A T E U...

Page 11: ...ged provided the package is not damaged an Act is made together with a representative of the manufacturer If a defect appears during warranty period the customer is to send NLJD to manufacturer with a...

Reviews: