Elverk CCMAX 1200i Operational Manual Download Page 11

9

7) Fuel Tank Cap

Turn counter clockwise to remove the tank cap.

8) Grounding Terminal

When the ground terminal is connected to the ground wire, to prevent electric 
shock. When the electrical equipment is grounded, the generator must be grounded. 

Grounding terminal

4.Start Generator

1) Turn the fuel tank cap knob to “ON”.
2) Turn the engine switch to “ON”.

3) a.Open the fuel
    b.Choke closed  

Summary of Contents for CCMAX 1200i

Page 1: ...INVERTER GENERATOR OPERATIONAL MANUAL...

Page 2: ...or other changes the content of this operational manual may be a little difference with actual situation We reserve the right to revise the operational manual in any time and without notice Thanks for...

Page 3: ...1...

Page 4: ...Control System 4 Start Generator 5 Stop The Generator 6 Use Generator 7 Check Before Operation 8 Start Engine And Connect The Load 9 Maintenance 10 Storage And Transportation 11 Trouble Shooting 12 C...

Page 5: ...3 1 Safety Insruction...

Page 6: ...4...

Page 7: ...5...

Page 8: ...Recoil starter grip 5 Left shell 6 Handle 7 Muf er cover plate 8 Appearance cover plate 9 Engine oil cover plate 1 Control Panel 1 Running light 2 Overload light 3 Engine oil lamp 4 Engine switch 5 E...

Page 9: ...h causes the inverter to overheat or the AC current to increase At this time the AC protector works and stops the generator to protect the generator and the connected electrical equipment The AC indic...

Page 10: ...8 4 AC Indicator AC Indicator 5 DC Protector 6 ECO Switch 4350...

Page 11: ...the ground terminal is connected to the ground wire to prevent electric shock When the electrical equipment is grounded the generator must be grounded Grounding terminal 4 Start Generator 1 Turn the...

Page 12: ...hand starter grasp the handling handle of the generator to prevent the generator from overturning 5 Stop The Generator 6 Use Generator 1 Generator Operating Environment 1 Stop all the electric equipme...

Page 13: ...11 OK ON OK 2 Generator Wire Connection...

Page 14: ...ing will shorten the generator life If there are several loads or equipments connected on the generator at the same time make sure rstly start the equipment that with highest starting current then mid...

Page 15: ...13 Output Powe 1000W 800W 350W...

Page 16: ...rburetor which is suitable for high altitude be assembled on the generator that is used in low altitude the rare mixed gas will make the generator power down too hot or serious damage 6 Used in High A...

Page 17: ...15 Fuel the highest level 7 Check Before Operation span Synthetic 5W 30 oil is recommended 104F 86 68 50 32 14 4 22 40C 30 20 10 0 10 20 30 SAE 30 10W 30 Synthetic 5W 30 5W 30...

Page 18: ...the right to the close position 2 Connected To The Load When using electrical equipment that needs large starting current such as inductive and capacitive loads the fuel saving switch must be set in o...

Page 19: ...17 3 Overload Processing or AC output current increases...

Page 20: ...to wash the skin immediately and thoroughly From an environmental point of view please deal with the waste oil produced after use We strongly recommend that you put the waste oil into a sealed contain...

Page 21: ...of air lter to ensure it is in good condition and clean Do not use solvents near smoking or near the ame If the foam lter is dirty please clean the foam lter core Clean and dry the lter element with...

Page 22: ...20 Caution Please use the appropriate calorie spark plug 4 Fuel Tank Filter Caution Be sure to tighten the tank cover 5 Muf er Replace the muf er net cover...

Page 23: ...21 10 Storage And Transportation 1 Emptying Fuel Note Do not connect any electrical equipment the engine running time depends on the fuel tank in the remaining fuel 2 Generator Transportation...

Page 24: ...of oil Oil level is too low 3 Circuit system a Turn ON the engine switch b Sparks is bad c The spark plug is stained with carbon and moisture d Poor ignition system 4 Poor compression a Piston and cyl...

Page 25: ...23 12 Circuit Diagram...

Page 26: ...Oil Capacity L Noise dB 7m Rated Power kW Rated Voltage V Rated Frequency Hz Power Factor Insulation Grade Performance Grade Dimension L W H mm N W kg Engine Genera Tor Whole sets 145F P Single Cylin...

Page 27: ...25...

Reviews: