
© 2021, Elvaco AB. All rights reserved. The documentation and product are provided on an “as is” basis only and may contain deficiencies or inad-
equacies. Elvaco AB takes no responsibility for damages, liabilities or other losses by using this product. No part of the contents of this manual
may be transmitted or reproduced in any form by any means without the written permission of Elvaco AB. Printed in Sweden.
CMi6160 Quick manual English
Version: 1.0
TECHNICAL SPECIFICATIONS
Mechanics
Dimensions (w x h x d)
43 x 37 x 9 mm
Mounting
In Diehl Metering SHARKY 775 or SCYLAR
INT 8 module slot 2
External antenna
connector
MCX female
Antenna max gain
4 dBi
SIM card
Slide, size Nano
Electrical connections
Battery supply
Externally mounted Diehl Metering
D-Cell
Battery life time
13+1 year
The battery life time is based on ECL0 and
hourly reading sent once / day.
Electrical characteristics
Nominal voltage Battery
3.0 VDC
Power consumption
(max)
400 mA
Power consumption
(sleep mode)
6
µA
Environmental specifications
Operating temperature
+5 °C to +55 °C
Operating humidity
0 - 93 % RH, no condensation
Operating altitude
2000 m
Pollution degree
Degree 1
Usage environment
Indoors
Storage temperature
-20 °C to +60 °C (Module)
Mobile network
Band
20, 8, 3 (NB-IoT)
3GPP
Release 14 (NB2)
Transmit power
Maximum 23.0 dBm
Receiver sensitivity
-135 dBm
User interface
Green LED
Start-up, Network connection
Red LED
Start-up
Push button
Start-up, Reboot
Configuration
• NFC via Elvaco OTC App
• Via LwM2M (Elvaco Evo DM-system, or
third-party DM-system)
• Preconfig on delivery
CONTACT INFORMATION
Elvaco AB Technical support:
E-mail: [email protected]
Online: www.elvaco.com
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, Elvaco declares that the radio equipment type CMi6160 is in
compliance with the following directives:
- 2014/30/EU (EMC)
- 2014/35/EU (LVD)
- 2014/53/EU (RED)
- 2011/65/EU + 2015/863 (RoHS).
The complete Declaration of Conformity can be found at www.elvaco.
se/en > Search on product name.
SIMPLIFIED UK DECLARATION OF CONFORMITY
Hereby, Elvaco declares that the radio equipment type CMi6160 is in
compliance with the following directives:
- Electromagnetic Compatibility Regulations 2016
- Electrical Equipment (Safety) Regulations 2016
- Radio Equipment Regulations 2017
- The Restriction of the Use of Certain Hazardous Substances in
Electrical and Electronic Equipment Regulations 2012
The complete Declaration of Conformity can be found at www.elvaco.
se/en > Search on product name
SAFETY
Install the antenna / product minimum distance 20 cm from person.
The warranty does not cover damage to the product caused by usage in
any other way than described in this manual. Elvaco AB can not be liable
for personal injury or property damage caused by usage in any other way
than described in this manual.
By default, the product is set to passive mode, which means no messages
will be transmitted from the device. There are two ways to activate the
product:
1.
Press and hold down the push button (6) for at least 5 seconds until
the green LED (2) lights up.
2.
Via the Elvaco mobile application. Go to the Apply tab, set the
Power mode to “Active”, push “Apply” and place the phone on the
back side of the meter, next to the module. Make sure to hold the
phone still until the phone vibrates.
Upon start-up, the module will attempt to connect to the mobile
network. The phase is indicated by short flashes on the green LED. After
successfully connecting to the mobile network, the green LED will light
up for 8 seconds, as indicated by the figure below.