CMi6160
User’s Manual English
CMi6160
User’s Manual English
page | 15 (38)
[2022-10]
v1.4
Op.
LwM2M object
LwM2M resource
ID
Type
Range or
Enumeration
Comment
R
Elvaco NB-IoT
Status
ECL
33907/0/
3
Integer
0..2
R
Elvaco NB-IoT
Status
RSSI
33907/0/
4
Integer
[dBm *10]
R
Elvaco NB-IoT
Status
SNR
33907/0/
5
Integer
[dB*10]
R
Elvaco NB-IoT
Status
MDM connection
status
33907/0/
10
Integer
0: OK
1: Connecting
2: No
credentials
3: DTLS
Rejected
4: MQTT-SN
F
ailed
5: MQTT-SN
Rejected
R
Elvaco Meter
Info
Meter Model
33908/0/
0
String
-
R
Elvaco Meter
Info
Meter ID
33908/0/
1
Integer
R
Elvaco Meter
Info
Comm status
33908/0/
2
Integer
0: OK
1: No meter
detected
2: Error
R
Elvaco Meter
Info
Error flags
33908/0/
3
Opaque
Meter Error flags
R
Elvaco NB-IoT
Info
IMSI
33909/0/
0
Integer
SIM IMSI
R
Elvaco NB-IoT
Info
ICCID
33909/0/
1
Integer
SIM ICCID
R
Elvaco NB-IoT
Info
Registrations
33909/0/
2
Integer
NB-IoT
Registrations
R
Elvaco NB-IoT
Info
Last Registration
duration
33909/0/
3
Integer
NB-IoT Last
Regsitration
Duration
R
Elvaco NB-IoT
Info
Modem Model
33909/0/
4
String
NB-IoT Modem
Model
R
Elvaco NB-IoT
Info
Modem Firmware
33909/0/
5
String
NB-IoT Modem
Firmware
Table 1: CMi6160 status/configuration parameters