background image

www.prolight.co.uk

Virtuoso 1000 Profile RGBAL

  

User Manual

18

Operating instructions

Operating instructions

Fixture information:

To access the fixture information press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons until 

“INFO” 

is highlighted on the LCD display.  Press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 

buttons to select between 

“VERSION” 

and 

“RDM”

. If VERSION is highlighted press the 

“ENTER”

 button 

and the version number and manufacture date will be displayed. If RDM is highlighted, press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to select between 

“UID” 

and 

“LABEL”

. If UID is 

highlighted press the 

“ENTER”

 button and the fixtures RDM UID will be displayed. If LABEL is highlighted 

press the 

“ENTER”

 button and the model number will be displayed.

INFO

VERSION

RDM

Vxx

xx/xx/xxxx

VERSION

INFO
VERSION

RDM

RDM

UID

LABEL

0x09A5xxxxxxxx

UID

RDM
UID

LABEL

Virtuoso

1000P-5C

LABEL

Summary of Contents for Virtuoso 1000 Profile

Page 1: ...Order codes ELUM132 Virtuoso 1000 Profile RGBAL User Manual ...

Page 2: ...is will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 100 240V AC 50 60Hz Make sure that the po...

Page 3: ...trolled fan for whisper quiet operation Handle on rear panel Virtuoso 1000 Profile RGBAL Specifications Virtuoso 1000 Profile RGBAL Power consumption 305W Fuse T6 3A 250V Power supply 100 240V 50 60Hz Dimensions 520 x 310 x 540mm Weight 8 3kg Order code ELUM132 The Virtuoso 1000 Profile features an advanced RGBAL LED system that outputs a flat and even field and is suitable for many applications H...

Page 4: ...X output 05 5 Pin DMX input 06 5 Pin DMX output 07 PowerCON input 08 PowerCON output 09 Fuse T6 3A 250V 10 Shutters 11 Hanging bracket 12 Hanging bracket adjustment knob 13 Carry handle In the box 1 x fixture 1 x power cable 1 x user manual 05 07 13 06 08 03 01 09 10 10 04 03 02 02 11 12 10 10 145mm 35mm 360mm 540mm 250mm 310mm 380mm 225mm 520mm 587mm ...

Page 5: ...s the material being used at the installation area and periodic safety inspections of the fixture and installation material If you do not have the relevant experience and or qualifications please do not attempt the installation yourself The installation should be checked annually by a qualified person The eLumen8 Virtuoso 1000 Profile RGBAL can be operated in a number of mounting positions as show...

Page 6: ...stallation 1 Fasten the clamp to the fixtures bracket with a bolt and lock nut through one of the mounting holes 2 Mount the fixture onto your truss system via the clamp and tighten to ensure secure 3 Pull the safety cable through the fixture bracket and around the truss 1 2 3 ...

Page 7: ...rd until you achieve the desired focus 3 Once the fixture is focussed tighten the beam focus knobs Rotating the Barrel Assembly 1 Loosen the barrel rotation knobs located at the bottom of the fixture do not remove the knobs or the barrel assembly 2 Rotate the barrel into the desired position 3 Once the barrel is rotated tighten the barrel rotation knobs Beam focus knobs Beam focus knobs Barrel rot...

Page 8: ...en the screws on the slot cover do not remove the screws 2 Slide to cover completely forward to expose the slot 3 Insert the iris or motorised pattern device When installing an iris install the flat side towards the shutters and make sure the iris handle extends upwards from the slot 4 Slide the cover back towards the shutters until it meets the iris handle Make sure any handles or adjustment tool...

Page 9: ... co uk Virtuoso 1000 Profile RGBAL User Manual 9 Shutters Shutters Shutters The shutters are located inside the barrel They can be adjusted via the shutter handles to adjust the shape of the beam Shutter adjustment ...

Page 10: ...on on the top right Pressing the ENTER button once will take the user to the fixtures main menu Using the UP and DOWN buttons you can then navigate between the different options in the main menu Pressing the ENTER button on one of these options allows you to access the sub menu where you can use the UP and DOWN buttons to select option value required Once the option value has been selected press t...

Page 11: ... STROBE STATIC RED GREEN BLUE AMBER LIME STROBE 255 255 255 255 255 25 Preset colour mode To access preset colour mode press the MENU button and use the UP and DOWN buttons until PRESET COLOUR is highlighted on the LCD display Press the ENTER button and use the UP and DOWN buttons to select the various colours Press the ENTER button to confirm the setting L106 Primary Red R05 Rose Tint L194 Surpri...

Page 12: ...ENTER button to confirm the setting Channel mode personality setting To access the fixtures channel mode personality setting press the MENU button and use the UP and DOWN buttons until PERSONALITY is highlighted on the LCD display Press the ENTER button and use the UP and DOWN buttons to select between HSIC 8 channel SIMPLE 8 channel SDO 6 channel COLOUR 8BIT 11 channel or COLOUR 16BIT 17 channel ...

Page 13: ...rting to the slave units The front lens will turn green if the export has completed successfully If there are any problems whilst exporting the front lens will turn red SETTING UPLOAD RESET DIMMER DMX FAIL PERFORMANCE PWM RATE FULL POWER CCT Pass code SEND Reset setting To access the fixtures reset setting use the UP and DOWN buttons to select RESET Press the ENTER button Pass code will now be dis...

Page 14: ... slow OFF Dimmer speed off SETTING UPLOAD RESET DIMMER DMX FAIL PERFORMANCE PWM RATE FULL POWER CCT DIMMER OFF DIM1 DIM2 DIM3 DIM4 DMX fail setting To access the DMX fail setting use the UP and DOWN buttons to select DMX FAIL Press the ENTER button and use the UP and DOWN buttons to select between SAVE and BLACK Press the ENTER button to confirm the setting SAVE The fixture will remember the last ...

Page 15: ...el performance mode designed to operate at the lowest noise possible but with a moderate output POWER This is an output performance mode designed to operate at full power with no consideration for the noise level SETTING UPLOAD RESET DIMMER DMX FAIL PERFORMANCE PWM RATE FULL POWER CCT PERFORMANCE LIVE STUDIO POWER PWM rate setting refresh rate This setting allows the refresh rate to be adjusted To...

Page 16: ...he LCD display Press the ENTER button and use the UP and DOWN buttons to between ON and OFF Press the ENTER button to confirm the setting When this is set to ON the passcode will need to be entered each time the display goes off The passcode sequence is UP DOWN UP DOWN ENTER XY Offset There is also an XY OFFSET sub menu within the settings menu this can be set between HIDE default and SHOW When se...

Page 17: ...and DOWN buttons to select between 2700K 3000K 3200K 3500K 4000K 4200K 4500K 5600K 6000K 6500K 7200K 8000K and 10000K Press the ENTER button to enter the selected menu Now use the UP and DOWN buttons to select between X FINE and Y FINE these settings will adjust the tint of the CCT Press the ENTER button and use the UP and DOWN buttons to adjust between 200 and 200 Press the ENTER button to confir...

Page 18: ...VERSION and RDM If VERSION is highlighted press the ENTER button and the version number and manufacture date will be displayed If RDM is highlighted press the ENTER button and use the UP and DOWN buttons to select between UID and LABEL If UID is highlighted press the ENTER button and the fixtures RDM UID will be displayed If LABEL is highlighted press the ENTER button and the model number will be ...

Page 19: ...00 009 Dimming mode set in menu 010 029 No function 030 069 Dimming speed 1 070 129 Dimming speed 2 130 189 Dimming speed 3 190 255 Dimming speed 4 CH8 000 009 No function 010 080 Live performance mode 081 160 Studio performance mode 161 240 Power performance mode 241 255 No function 8 channel mode SIMPLE Channel Value Function CH1 000 255 Master dimmer 0 100 CH2 000 255 Red 0 100 CH3 000 255 Gree...

Page 20: ... 1 4 Minusgreen 151 160 L101 Yellow 161 170 L768 Egg Yolk Yellow 171 255 No function CH3 000 010 No function 011 030 2700K 031 050 3000K 051 070 3200K 071 090 3500K 091 110 4000K 111 130 4200K 131 150 4500K 151 170 5600K 171 190 6000K 191 210 6500K 211 230 7200K 231 255 8000K CH4 000 009 No function 010 099 Strobe slow fast 100 109 No function 110 179 Lightning strobe 180 189 No function 190 255 R...

Page 21: ...02 Half C T Blue 131 140 L328 Follies Pink 141 150 R3314 Tough 1 4 Minusgreen 151 160 L101 Yellow 161 170 L768 Egg Yolk Yellow 171 255 No function CH8 000 010 No function 011 030 2700K 031 050 3000K 051 070 3200K 071 090 3500K 091 110 4000K 111 130 4200K 131 150 4500K 151 170 5600K 171 190 6000K 191 210 6500K 211 230 7200K 231 255 8000K Channel Value Function CH9 000 009 No function 010 099 Strobe...

Page 22: ...100 L213 White Flame Green 101 110 R377 Iris Purple 111 120 R80 Primary Blue 121 130 L202 Half C T Blue 131 140 L328 Follies Pink 141 150 R3314 Tough 1 4 Minusgreen 151 160 L101 Yellow 161 170 L768 Egg Yolk Yellow 171 255 No function Channel Value Function CH14 000 010 No function 011 030 2700K 031 050 3000K 051 070 3200K 071 090 3500K 091 110 4000K 111 130 4200K 131 150 4500K 151 170 5600K 171 19...

Page 23: ... B A L 92124 6716 17976 3112 23108 83404 23031 1679 4494 778 5777 20851 10236 746 1997 345 2567 9267 19 5757 419 1123 194 1444 5212 3684 268 719 124 924 3336 0m 1m 2m 3m 4m 5m 26 Lux FULL ON R G B A L 60800 5508 11996 2100 13432 39640 15200 1377 2999 525 3358 9910 6755 612 1332 233 1492 4404 26 3800 344 749 131 839 2477 2432 220 479 84 537 1585 ...

Page 24: ...L ON R G B A L 40000 3720 8544 1432 8832 27368 10000 930 2136 358 2208 6842 4444 413 949 159 981 3040 36 2500 232 534 89 5 552 1710 1600 148 341 57 2 353 1094 0m 1m 2m 3m 4m 5m 50 Lux FULL ON R G B A L 10356 1456 3396 572 3652 10944 2589 364 849 143 913 2736 1150 161 377 63 5 405 1216 50 647 91 212 35 7 228 684 414 58 2 135 22 8 146 437 ...

Page 25: ...ux FULL ON R G B A L 107944 9572 25612 4124 35740 83404 51432 3684 9084 1548 10576 31068 26986 2393 6403 1031 8935 20851 12858 921 2271 387 2644 7767 11993 1063 2845 458 3971 9267 5714 409 1009 172 1175 3452 6746 598 1600 257 2233 5212 3214 230 567 96 661 1941 4317 382 1024 164 1429 3336 2057 147 363 91 9 423 1242 Photometric Charts ...

Page 26: ...Lux FULL ON R G B A L 50 Lux FULL ON R G B A L 58480 5192 12232 2064 12788 39924 21000 1948 4452 736 4772 14104 14620 1298 3058 516 3197 9981 5250 487 1113 184 1193 3526 6497 576 1359 229 1420 4436 2333 216 494 81 7 530 1567 3655 324 764 129 799 2495 1312 121 278 46 298 881 2339 207 489 82 5 511 1596 840 77 9 178 29 4 190 564 ...

Page 27: ...lowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fix...

Page 28: ...ne a cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal 3 pin XLR male Pin 1 GND screen Pin 2 Signal Pin 3 Signal 5 pin XLR male Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C DMX setup Termination reduces signal ...

Page 29: ...tures that can be connected is 6 fixtures 240V or 3 fixtures 120V including the first fixture After the maximum number of fixtures are connected a new power run will need to be started Please note Caution should be used when power linking other fixtures to the Virtuoso 1000 Profile as the power consumption of other fixtures will vary Fixtures fitted with lamps often require 2 3 times more current ...

Page 30: ...ent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environme...

Page 31: ...www prolight co uk Virtuoso 1000 Profile RGBAL User Manual 31 ...

Page 32: ...www prolight co uk Virtuoso 1000 Profile RGBAL User Manual 32 ...