background image

Order codes: ELUM019

Kudos 700 Beam 

User Manual

Summary of Contents for Kudos 700 Beam

Page 1: ...Order codes ELUM019 Kudos 700 Beam User Manual ...

Page 2: ...iquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 100 240V AC 50 60Hz Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically If the eq...

Page 3: ...ul to the eyes Avoid looking directly into the light source CAUTION If the lens gets damaged ie cracks or deep scratches so the output is impaired then it must be replaced CAUTION The maximum ambient temperature Ta of 40 must not be exceeded CAUTION To avoid damage to internal parts ie optics colour filters gobos prisms frost filters iris shutters motors belts wiring or LEDs never expose the front...

Page 4: ...0 Beam Specifications Kudos 700 Beam Power consumption 157W Fuse F2A 250V Power supply 100 240V 50 60Hz Dimensions 534 x 327 x 222mm Weight 14kg Order code ELUM019 0m 5m 10m 15m 20m 2 Lux 80000 20000 8890 2 5000 The Kudos 700 Beam projects a tight 2 concentrated beam from its powerful 110W LED source Inside the ergonomic head are 2 circular rotating prisms 8 facet and 16 facet 12 colours 5600K 320...

Page 5: ...www prolight co uk Kudos 700 Beam User Manual 5 338mm 428mm 469mm 534mm Technical specifications 122mm 222mm 310mm 327mm 210mm 98mm ...

Page 6: ...ications 01 LCD display 02 Function buttons 03 5 Pin DMX input 04 5 Pin DMX output 05 PowerCON input 06 PowerCON output 07 Fuse F2A 250V 08 Power switch 09 Fans In the box 1 x fixture 2 x omega clamps 1 x power cable 1 x user manual 09 08 01 02 02 04 05 06 07 03 09 ...

Page 7: ...s the material being used at the installation area and periodic safety inspections of the fixture and installation material If you do not have the relevant experience and or qualifications please do not attempt the installation yourself The installation should be checked annually by a qualified person The eLumen8 Kudos 700 Beam can be operated in a number of mounting positions as shown in the diag...

Page 8: ...lamp quick lock fasteners with the respective holes on the bottom of the unit 3 Tighten both locking fasteners clockwise on each omega clamp ensuring they re fully secure 4 Mount the fixture onto your truss system via the clamps and tighten to ensure secure 5 Pull the safety cable through the safety cable holes located on the metal base plate on the underside of the fixture and around the truss 1 ...

Page 9: ... prolight co uk Kudos 700 Beam User Manual 9 9 0 9 0 9 0 9 0 Pan Tilt Lock Mechanism LOCKED UNLOCKED Pan mechanism lock and release every 90 LOCKED UNLOCKED Tilt mechanism lock and release every 90 9 0 9 0 ...

Page 10: ... value has been selected press the ENTER button once more to confirm the setting To exit out of any of the above options press and hold the MENU button Error Codes When the unit is powered on the unit will automatically perform a motor reset If there is a problem with any of the motors you will need to check the Error Log once the home screen appears To do this follow the instructions on page 17 E...

Page 11: ...m the setting Main Menu Defaults are in grey DMX channel mode To access the DMX channel mode press the MENU button on the front of the unit to show Channel Mode on the LCD display Now press the ENTER button and use the UP and DOWN buttons to set the required DMX channel Press the ENTER button to confirm the setting DMX fail Sets what the fixture does when the DMX signal is lost To access the DMX f...

Page 12: ...Rot xxx 11 Frost xxx 12 Focus xxx Operating instructions Manual control To access manual control mode press the MENU button on to show Manual Control on the LCD display Press the ENTER button and use the UP and DOWN buttons to select the various options Press the ENTER button and use the UP and DOWN buttons to select between 000 255 Press the ENTER button to confirm the setting Default 000 ...

Page 13: ...TER button and use the UP and DOWN buttons to select between Yes and No Press the ENTER button to perform the motor reset when yes is selected 7 P T Invert 1 Pan Invert 2 Tilt Invert 1 ON 1 ON 2 Off 2 Off Pan invert To access the pan invert setting press the MENU button on to show P T Invert on the LCD display Press the ENTER button and use the UP and DOWN buttons to select Pan Invert Press the EN...

Page 14: ... Sets whether the fixture blacks out whilst changing colour To access the blackout whilst colour change setting press the MENU button on to show Blackout on the LCD display Press the ENTER button and use the UP and DOWN buttons to select BL O Colour Press the ENTER button and use the UP and DOWN buttons to select between ON and Off Press the ENTER button to confirm the setting Blackout whilst gobo...

Page 15: ...nd use the UP and DOWN buttons to select Backlight Press the ENTER button and use the UP and DOWN buttons to select between Off and On Press the ENTER button to confirm the setting Display inverse To access the display inverse setting press the MENU button on to show Display on the LCD display Press the ENTER button and use the UP and DOWN buttons to select Display Inverse Press the ENTER button a...

Page 16: ... the various options Press the ENTER button and use the UP and DOWN buttons to select between 000 255 Press the ENTER button to confirm the setting Please note Calibration settings are set when the fixture is manufactured This can be changed manually for home position adjustment Performing a factory reset will not change these settings Factory Reset Resets all the fixtures factory settings To acce...

Page 17: ...s the MENU button once to display Information on the LCD display Press the ENTER button and use the UP and DOWN buttons to show Error Record on the LCD display Press the ENTER button The unit will now display the fixtures run time Fixture Information Displays the fixtures version and RDM ID To display the fixture information press the MENU button once to display Information on the LCD display Pres...

Page 18: ...51 Lime Green Lavender 052 055 Lavender 056 059 Lavender Pink 060 063 Pink 064 068 Pink Yellow 069 072 Yellow 073 076 Yellow Magenta 077 081 Magenta 082 085 Magenta Blue 086 089 Blue 090 093 Blue CTO 260 094 098 CTO 260 099 102 CTO 260 CTO 190 103 106 CTO 190 107 110 CTO 190 CTB 8000 111 115 CTB 8000 116 119 CTB 8000 Dark Blue 120 123 Dark Blue 124 127 Dark Blue Open 128 255 Colour Wheel Rotation ...

Page 19: ...slow fast 173 179 Gobo 4 shake slow fast 180 185 Gobo 5 shake slow fast 186 191 Gobo 6 shake slow fast 192 198 Gobo 7 shake slow fast 199 204 Gobo 8 shake slow fast 205 211 Gobo 9 shake slow fast 212 217 Gobo 10 shake slow fast 218 223 Gobo 11 shake slow fast 224 230 Gobo 12 shake slow fast 231 236 Gobo 13 shake slow fast 237 243 Gobo 14 shake slow fast 244 249 Gobo 16 shake slow fast 250 255 Gobo...

Page 20: ...Green 047 051 Lime Green Lavender 052 055 Lavender 056 059 Lavender Pink 060 063 Pink 064 068 Pink Yellow 069 072 Yellow 073 076 Yellow Magenta 077 081 Magenta 082 085 Magenta Blue 086 089 Blue 090 093 Blue CTO 260 094 098 CTO 260 099 102 CTO 260 CTO 190 103 106 CTO 190 107 110 CTO 190 CTB 8000 111 115 CTB 8000 116 119 CTB 8000 Dark Blue 120 123 Dark Blue 124 127 Dark Blue Open 128 255 Colour Whee...

Page 21: ...shake slow fast 192 198 Gobo 7 shake slow fast 199 204 Gobo 8 shake slow fast 205 211 Gobo 9 shake slow fast 212 217 Gobo 10 shake slow fast 218 223 Gobo 11 shake slow fast 224 230 Gobo 12 shake slow fast 231 236 Gobo 13 shake slow fast 237 243 Gobo 14 shake slow fast 244 249 Gobo 16 shake slow fast 250 255 Gobo 17 shake slow fast 18 channel mode cont Channel Value Function CH11 000 127 No functio...

Page 22: ...light co uk Kudos 700 Beam User Manual 22 Static gobos Open Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 7 Gobo 8 Gobo 9 Gobo 10 Gobo 11 Gobo 12 Gobo 13 Gobo 14 Gobo 15 Gobo 16 Gobo 17 Operating instructions ...

Page 23: ... all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture a...

Page 24: ...ble adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal 3 pin XLR male Pin 1 GND screen Pin 2 Signal Pin 3 Signal 5 pin XLR male Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C DMX setup Termination reduces signal transmi...

Page 25: ...ncluding the first fixture After the maximum number of fixtures are connected a new power run will need to be started Please note Caution should be used when power linking other fixtures to the Kudos 700 Beam as the power consumption of other fixtures will vary Fixtures fitted with lamps often require 2 3 times more current on startup these may require their own power source Please contact your lo...

Page 26: ...sible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally ...

Page 27: ...www prolight co uk Kudos 700 Beam User Manual 27 ...

Page 28: ...www prolight co uk Kudos 700 Beam User Manual 28 ...

Reviews: