www.prolight.co.uk
MP60 LED Fresnel CW
User Manual
6
DMX mode:
Operating in a DMX control mode environment gives the user the greatest flexibility when it comes
to customising or creating a show. In this mode you will be able to control each individual trait of the
fixture and each fixture independently.
To access the DMX address mode, press the
“MENU”
button on the front of the unit to show
“DMX ADDR”
on the LCD display. Now press the
“ENTER”
button and use the
“UP”
and
“DOWN”
buttons
to set the required DMX address. Press the
“ENTER”
button to confirm the setting.
To exit out of any of the above options, press the
“MENU”
button.
To access the DMX channel mode, press the
“MENU”
button on the front of the unit to show
“Channel”
on the LCD display. Now press the
“ENTER”
button and use the
“UP”
and
“DOWN”
buttons to
choose one of the 1 or 2 DMX channel modes. Press the
“ENTER”
button to confirm the setting.
To exit out of any of the above options, press the
“MENU”
button.
Operating instructions
Channel Value
Function
1
000-255 Master dimmer (0-100%)
2
000-030 Linear LED dimming curve
031-060 Linear Halogen dimming curve
061-090 Square LED dimming curve
091-120 Square Halogen dimming curve
121-150 Inverse Square LED dimming curve
151-180
Inverse Square Halogen dimming curve
181-210
S-curve LED dimming curve
211-255 S-curve Halogen dimming curve
2 channel mode:
Channel Value
Function
1
000-255 Master dimmer (0-100%)
1 channel mode: