Electrical Installation
64 Operating instructions RHD
ELTROPLAN
-
REVCON
Elektrotechnische Anlagen GmbH
Danger!
At this configuration the input current of the frequency converter must not exceed the nominal
current of the RHF-RA!
At non observance damages at the RHF-RA and / or the frequency converter cannot be ex-
cluded!
Legend for figure 7.3.2 (REVCON
RHD B0/D0 and FC with RHF-RA
)
1.
Fusing in accordance with controller manual.
2.
It is not allowed to connect any other devices except the frequency inverter and the
power feedback unit behind the main magnetic switch.
Danger!
If this is not observed, you take the risk that, in the case of switching off the mains during feed-
back the power, the voltage in that sector may rise up to a dangerous level. This may destroy
the connected devices and perhaps also the inverter and / or the power feedback unit. To avoid
such a situation, the power feedback unit is equipped with an overvoltage switch off, but never-
theless this hint should be observed!
3.
RHF-RA module
4.
Fusing in accordance with power feedback unit manual. This may be left out if at
position 1 a short-circuit proof line is used.
5.
Cross section in accordance with the relevant VDE-rules.
6.
Interference filter, optional.
7.
Fusing (230 V supply, <2A current input) in accordance with DIN VDE 0298 or
short circuit proof wiring.
8.
At these terminals one or more controllers (even with different power ratings) may
be attached, like it shown in figure 4.5.1. Even if several controllers are attached, the
wires have to be as
short and low impedance
as possible!
9.
The „ON“ or „RESET“ signal may be initiated via terminals 11 and 12:
Terminals 11 and 12:
Positive pulse (12-24 V DC); practicable e.g. via PLC
(terminal 11 +, terminal 12 -).