PECIFICATIONS AND MANUAL OPERATION
3.1 Technical data
MT50 1.0
MT150 1.0
Torque
1
10-50 Nm
50-150 Nm
Valve stem speed
1
7-17 rpm
5-15 rpm
Valve applications
2
Rolls-Royce Marine UT multi-turn bilge and X-over valve manifolds, PN10
DN50
DN80
DN100
DN125
DN150
Closing time
1
20 sec
25 sec
30 sec
60 sec
65 sec
Physical Properties
Dimensions (H/W/D)
411/ 115/ 224 mm
550/ 146/ 274 mm
Weight
15 kg
28 kg
Encapsulation
IP68 (5m 1 hr)
Corrosion protected aluminium enclosure
Operation temperature
-25
– 55
C
Colour
Black and silver
Over/ under temperature
protection
Motor current is switched off in case of over-temperature
Stator coils utilized as heating elements in case of low temperatures
Electrical and Control Properties
Supply voltage AC
110-240 V AC (50/60 Hz) or 125-230 V DC
Power consumption
Max: 120W/ 280 VA, Standby: 11W
Max: 240W/ 560 VA, Standby: 14W
Supply voltage DC at
actuator (min-nom-max)
3
20 - 24 - 28 VDC
Not available
Current at DC operation
<3 ADC (20VDC)
Open/Close time (20VDC)
ND50/80/100: 33s/42s/51s
Cable glands
Up to 4 pcs M20 glands allows serial connection of
power supply and fieldbus wiring.
Threaded holes in actuator capsule.
Use IP68 glands for all wires, EMC type for fieldbus wiring.
Control interfaces
Digital:
2 DI (Open & Close) & 3 DO (Open,Closed & Alarm)
CANopen Fieldbus:
Max 127 nodes per network, allows positioning and other
extended control of actuator.
Position sensor
Absolute position sensor, provides correct feedback even after a power failure.
Resolution 4,85 °/
Maximum 13 turns
Resolution 5,84 °/
Maximum 16 turns
Configuration
USB connection to PC using E3C, Manual EQS ID 1687
Configurable parameters
Valve type, Open and Closed positions .
Actuator speed, torque and valve position regions.
Inverted IO or fieldbus parameters depending on control interface
Emergency and safety
Manual operation
Standard feature using ergonomic crank shaft.
Mechanical valve position indicator.
Visual status indication by LED when actuator is powered.
Safety function disables motor in case of manual operation while actuator is
powered.
Number of turns
Closed - Open
39
49
59
70
80
1
Configurable using E3C, Manual EQS ID 1687
2
Adapted flange bracket and stem connection is required and must be ordered with the actuator
3
This implies that a VDC power grid should be star topology (e.g. one actuator per 24VDC power
line).
Summary of Contents for EQS 1374
Page 11: ...Page 11 of 41 This page is left intentionally blank ...
Page 13: ...Page 13 of 41 MT50 MT150 Fig 3 External dimensions 411 550 146 274 ...
Page 19: ...Page 19 of 41 This page is intentionally left blank ...
Page 32: ...Page 32 of 41 Fig 33 Example of control screen layout ...
Page 34: ...Page 34 of 41 Fig 35 24VDC power supply and Digital interface ...
Page 35: ...Page 35 of 41 This page is left intentionally blank ...
Page 37: ...Page 37 of 41 This page is left intentionally blank ...
Page 38: ......
Page 40: ...Page 40 of 41 Fig 36 Earthing procedure for QT 50 ...
Page 41: ...Page 41 of 41 SWBD 47 7485 5520 Email info eltorque com ...