background image

Operating Instructions

vario Discharging Bar flexBAR

Series R60L for AC Operation

BA-en-2082-2207

F010

52

y

Summary of Contents for flexBAR R60L Series

Page 1: ...Operating Instructions vario Discharging Bar flexBAR Series R60L for AC Operation BA en 2082 2207 F01052y...

Page 2: ...2 BA en 2082 2207_R60L...

Page 3: ...3 Installation and assembly 12 3 1 Assembling the R60L discharging bar 12 3 2 Length of the high voltage cable 17 3 3 Adjust the angle coupling 18 3 4 Operation without air support 19 3 5 Operation w...

Page 4: ...4 BA en 2082 2207_R60L...

Page 5: ...supply is off variable use in tight grounded machine spaces safety through function and malfunction monitoring continuous assembly slotting guarantees flexible installation no health hazards in case o...

Page 6: ...ength AL active length GL total length Discharging bar R60L fixed connection of the high voltage cable high voltage cable axial and radial design radial connection rotatable by 300 and locked by lock...

Page 7: ...supplies guarantee the optimum adaptation to the required operational data for the different active bar lengths Safe operation of the bars is ensured only by using the Eltex power supplies Other uses...

Page 8: ...e to be grounded see chapter 5 Mainte nance page 22 The bar must be mounted such that mechanical damage to the bar tips is ruled out see chapter 3 1 Assembling the R60L discharging bar page 12 When ro...

Page 9: ...tartup for any damage Any damaged components must be repaired or replaced before continuing to operate the unit or the units must be disabled Make sure that the units are clean at all times Dirt resul...

Page 10: ...it ted only when using the Eltex distributor as well as original high voltage cables and glands If any liquids seep into the spring tips and bar during cleaning they must dry completely before start u...

Page 11: ...reserves the right to make changes to the technical specifications without prior notice in order to adapt the units to state of the art engineering Eltex will provide the latest information on any cha...

Page 12: ...lip 3 Bracket small 6 Mounting angle The profile of the bar features a through going sideways groove in which the bar holders are positioned at regular distances The bar is fixed in place simply by ti...

Page 13: ...d via plastic holders An additional angle permitting easy fastening of sys tem profiles is available as an option see Fig 3 1 Discharging bar 4 Maschine wall 2 GRP round rod 5 Grounding cable 3 Alumin...

Page 14: ...ble e g chafing against rotating machine parts is ruled out To attach the bar use only the provided brackets made of plastic In applications involving moving bars e g film draw strips the high voltage...

Page 15: ...istance to the web ought to be kept free of any conductive material Fig 5 The distance of the emission points to the conductive earthed printing press area should be greater than to the substrate to b...

Page 16: ...ught on the spring tips This can damage the spring tips To avoid this we recommend the optionally available protection pro file This can be easily adapted and is available with a protective strip on o...

Page 17: ...ES51 and ES60 power supplies as factor of active bar length and total length of the high voltage cable Z01162e Fig 8 Loading capacity of the ES50 power supply as factor of active bar length and total...

Page 18: ...ps during ex factory delivery 1 Lock nut 2 Angle coupling To turn the angle connection proceed as follows loosen the lock nut align the angle coupling in its desired position re tighten the lock nut T...

Page 19: ...ds on the length of the bar If the air is supplied via both air connections then all hoses from the distributor to the connections must be of the same length same pressure conditions Fig 11 Position o...

Page 20: ...d must be measured near the air distributor The distributor cross section must be dimensioned to match the number of hose connec tions or in compliance with the consumption volume 1 Pressure gauge not...

Page 21: ...m adaptation to the specified operating conditions 4 1 Startup Once all the connections have been correctly made the system is opera tional and the supply voltage can be switched on at the power suppl...

Page 22: ...pistol and a brush with soft plastic bristles Clean grease ink glue paper dust etc off the discharging bar using a suitable solvent benzine Do not soak the bars and the high voltage cable in solvent C...

Page 23: ...rty discharging bars Measure Clean bar with compressed air and a brush Clean grease ink oil etc off the bar with a suitable solvent benzine For further malfunctions refer to the operating instructions...

Page 24: ...ig 13 Weight approx 1 6 kg m Operating voltage max 5 kV AC 50 250 Hz High voltage supply via Eltex power supplies High voltage connection high voltage cable encapsulated axial or radial lead out 300 r...

Page 25: ...82 2207_R60L 25 8 Dimensions AL active length GL total length Fig 13 R60L discharging bar shown with standard bracket Z 116289bc_2 O Y Fig 14 Bracket standard Z 115565y_4 6 Fig 15 Bracket small Z 1155...

Page 26: ...26 BA en 2082 2207_R60L Fig 16 Angle bracket Z 115565ay_6...

Page 27: ...or prefabricating the high voltage cable without flexible tube for power supply ES5x ES6x PI and distributer ESV61 _S ESVY61 _S 101366 Plug Y Set for prefabricating the high voltage cable with flexibl...

Page 28: ...e straight G1 4 DN10 MCH00915 Angle air nipple G1 4 DN8 102074 Angle air nipple G1 4 DN10 104952 Y hose socket DN8 103391 Y hose socket DN10 MCH00602 T reducing socket NW10 13 10 MCH02417 Hose with in...

Page 29: ...ing element Manometer Pressure switch open contact 3 m cable length Angle air nipple DN10 L plug in screw connection DN10 110407 Pressure regulator pressure control range 0 05 0 85 MPa connection thre...

Page 30: ...30 BA en 2082 2207_R60L...

Page 31: ...19 EN 55011 2016 Ai 2017 Relevant EU Directive 2011 65 EU Low Voltage Directive Safety of machinery Electrical equipment of machines General requirements EMC Directive Electromagnetic compatibility EM...

Page 32: ...mbH Blauenstra e 67 69 79576 Weil am Rhein Germany Phone 49 0 7621 7905 422 eMail info eltex de Internet www eltex de Eltex offices and agencies The addresses of all Eltex agencies can be found on our...